29945 URTICA CT FIRE21-1091 VALORJohnathan Baker
Subject: FIRE21-1091 TR36485 SPK FINAL LOT 2
Location: 29945 URTICA CT
Start:
End:
Recurrence:
Meeting Status:
Organizer:
Call Handling Mode 2:
Rep. Name: JUAN
Phone#: 951-358-9783
Wed 12/22/2021 3:00 PM
Wed 12/22/2021 3:30 PM
(none)
Meeting organizer
Menifee OFM
2
Cell#:
Co. Name: FSS
CrossSt: VALOR
HYDRANT SYSTEM
PASS
FAIL
FIRE ALARM
PASS
FAIL
Thrust block pre -pour
Rou h-wire inspection
Underground rou h
Function test
Underground h Oro
Quct deteCtorslvelacity
Flush
21. hr. balery test
Final
S rinkledmonitorin
SPRINKLER U.G.
Fin
Thrust block pre -pour
SPECIAL SUPPRESSION
Underground rough
\
Door• n test
Underground hydro
Ab rt test
Flush
echanical shutdown
Final
etector test
FIRE SPRINKLER
Deluge/pre-action
Weld inspection
41
Final
Overhead rough piping
UST/AST TANK
Overhead hydro
Installation
UG flush / OK to connect
/
/
Removal
Main drain/Inspect. Test
/
EmergencyEmwgency shut off
High pile stora e
/
Primary piping
In-racksprinklers
/
Seconda pipin
Hose racks
Dispensers & shear valves
X
Final
Final
KITCHEN HOOD EXTINGUISHING
MISC. INSPECTION
Detections stem
Spray booths
Function Test
Hood/duct extinguishing
Gas/Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hydrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
25
Steven Fox
Subject:
Location:
Start:
End:
Recurrence:
Organizer:
Call Handling Mode 2:
Rep. Name: JUAN
Phone#: 951-358-9783
FIRE21-1092 TR36485 O/H ROUGH/HYDRO LOT 2
29945 URTICA CT
Thu 9/2/2021 11:00 AM
Thu 9/2/2021 11:30 AM
(none)
Menifee OFM
2
Cell#:
Co. Name: FSS
VIUJJJI. WALUr[
HYDRANT SYSTEM
PASS
FAIL
FIRE ALARM
PASS
FAIL
Thrust block pre -pour
Rough -wire inspection
Underground rough
Function test
Underground hydro
Duct detectors/velocity
Flush
24 hr. battery test
Final
Sprinkler monitoring
SPRINKLER U.G.
Final
Thrust block pre -pour
SPECIAL SUPPRESSION
Underground rough
j Door fan test
Underground hydro
Abort test
Flush
Mechanical shutdown
Final
Detector test
FIRE SPRINKLER
Deluge/pre-action
Weld inspection
Final
X
Overhead rough piping
UST/AST TANK
X
Overhead hydro
i
Installation
UG flush / OK to connect
Removal
Main drain/Inspect. Test
Emergency shut off
High pile storage
Primary piping
In -rack sprinklers
Seconds piping
Hose racks
Dispensers & shear valves
Final
Final
KITCHEN HOOD EXTINGUISHING
MISC. INSPECTION
Detection system
Spray booths
Function Test
Hood/duct extinguishing
Gas/Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hydrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
Final
Final for occupancy