24514 WINTER CIRCLE FIRE21-1078 VALOR WESTJohnathan Baker Subject: FIRE21-1078 TR36485 SPK FINAL LOT 18 Location: 24514 WINTER CIRCLE Start: End: Recurrence: Organizer: Call Handling Mode 2: Rep. Name: JUAN Phone#: 951-358-9783 Fri 12/10/2021 1:00 PM Fri 12/10/2021 1:30 PM (none) Johnathan Baker 2 Cell#: Co. Name FSS Urubbo : VALUM VVCJ I HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre -pour Rough -wire inspection Underground rough Function test Under round hydro Duct detectors/velocity Flush 24 hr. battery/test Final Sprinkler n)6nitorin SPRINKLER U.G. Final / Thrust block pre -pour ECIAL SUPPRESSION Underground rough I DoOr,fan test Under round hydro MQft test Flush \ Wchanical shutdown Final etector test FIRE SPRINKLER ` i Deluge/pre-action Weld inspection Final Overhead rough piping UST/AST TANK Overhead hydro / Installation UG flush / OK to connect Removal Main drain/Inspect. Test Emergency shut off High pile storage Primapiping In-racksprinklers Secondary piping Hose racks 7 Dispensers & shear valves X Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detection system Spray booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High pile rack storage Nozzle model/placement / H.P. vents/access/corridors Fire alarm connection Tract access/hydrant verification Final Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extin uishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: Start Time: Finish Time: 29 Iliana Gutierrez Subject: FIRE21-1078 TR36485 O/H ROUGH/HYDRO LOT 18 Location: 24514 WINTER CIRCLE Start: End: Recurrence: Organizer: Call Handling Mode 2: Rep. Name: JUAN Phone#: 951-358-9783 Tue 8/24/2021 12:00 PM Tue 8/24/2021 12:30 PM (none) Menifee OFM 2 Cell#: Co. Name: FSS CrossSt: VALOR WEST HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre -pour Rough -wire inspection _ Underground rough Function test Underground hydro Duct detectors/velocity Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre -pour J SPECIAL SUPPRESSION Underground rough Door fan test Underground hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Deluge/pre-action Weld inspection Final X Overhead rough piping UST/AST TANK X Overhead hydro Installation UG flush / OK to connect Removal Main drain/Inspect. Test Emergency shut off High pile storage Primary piping In -rack sprinklers Secondary piping Hose racks Dispensers & shear valves Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detection system Spray booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High pile rack storage Nozzle model/placement H.P. vents/access/corridors Fire alarm connection Tract access/hydrant verification Final Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: Start Time: Finish Time: 31