29755 LAUREL CT FIRE21-0858 HERITAGE@BANNER(liana Gutierrez
Subject:
Location:
Start:
End:
Recurrence:
Organizer:
Call Handling Mode 2:
Rep. Name: HECTOR
Phone#: 951-847-2908
FIRE21-0858 TR32102 SPK FINAL LOT 131
29755 LAUREL CT
Wed 10/6/2021 2:30 PM
Wed 10/6/2021 3:00 PM
(none)
Sonya Rivera-Bu
2
Cell#:
Co. Name: FSS
CrossSt: HERITAGE 2 BANNER
HYDRANT SYSTEM
PASS
FAIL
. FIRE ALARM
PASS
FAIL
Thrust block pre -pour
Rou h7*ire inspection
Under round rough
Funprion test
Underground hydro
D,Act detectors/velocity
Flush
24 hr. battery test
Final
Sprinkler monitoring
SPRINKLER U.G.
Final
Thrust block pre -pour
SPECIAL SUPPRESSION
Underground rough
Door fan test
Underground hydro
Abort test
Flush
Mechanical shutdown
Final
r test
FIRE SPRINKLER
a/pre-action
Weld inspection
kb
:inal
Overhead rough piping
UST/AST TANK
Overhead hydro
to
Installation
UG flush / OK to connect
Removal
Main drain/inspect. Test
Emergenc shut off
High pile storage
Prima piping
In -rack sprinklers
Secondary piping
Hose racks
Dispensers & shear valves
Final
\
Final
KITCHEN HOOD EXTINGUISHING
MISC. INSPECTION
Detections stem
Spray booths
Function Test
Hood/duct extinguishing
Gas/Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hydrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
Final
Final for occupanc
Start Time:
Finish Time:
Start Time:
Finish Time:
11
Iliana Gutierrez
Subject: FIRE21-0858 TR32102 O/H ROUGH/HYDRO LOT 131
Location: 29755 LAUREL CT
Start:
End:
Recurrence:
Organizer:
Call Handling Mode 2:
Rep. Name: HECTOR
Phone#: 951-847-2908
Mon 8/16/2021 10:00 AM
Mon 8/16/2021 10:30 AM
(none)
Steven Fox
N
Cell#:
Co. Name: FSS
I.IUSSJI: rir-MI I MUr- CC71 tSHIVIVtK
HYDRANT SYSTEM
PASS
FAIL
FIRE ALARM
PASS
FAIL
Thrust block pre -pour
Rough -wire inspection
Underground rough
Function test
Underground hydro
Duct detectors/velocity
Flush
24 hr. battery test
Final
Sprinkler monitoring
SPRINKLER U.G.
Final
Thrust block pre -pour
SPECIAL SUPPRESSION
Underground rough
Door fan test
Underground hydro
Abort test
Flush
Mechanical shutdown
Final
Detector test
FIRE SPRINKLER
Deluge/pre-action
Weld inspection
Final
Overhead rough piping
UST/AST TANK
X
Overhead hydro
Installation
UG flush / OK to connect
Removal
Main drain/Inspect. Test
Emergency shut off
High pile storage
Primary piping
In -rack sprinklers
Secondary piping
Hose racks
Dispensers & shear valves
Final
Final
KITCHEN HOOD EXTINGUISHING
MISC. INSPECTION
Detection system
Spray booths
Function Test
Hood/duct extinguishing
Gas/Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hydrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
Final
Final for occupancy
Start Time:
Finish Time:
Start Time:
J Finish Time:
21