24478 MONTEGOMERY WAY FIRE20-0561 TRIBUTE(liana Gutierrez
Subject:
Location:
Start:
End:
Recurrence:
Organizer:
Call Handling Mode 2:
Rep. Name. JUAN
Phone#: 951-358-9783
FIRE20-0561 TR36485-5 SPK FINAL LOT 14
24478 MONTGOMERY WAY
Wed 11/4/2020 9:00 AM
Wed 11/4/2020 9:30 AM
(none)
Menifee OFM
2
Cell#:
Co. Name:
FSS
l�I VJJJI. I rXI OU r C
HYDRANT SYSTEM
PASS
FAIL
FIRE ALARM
PASS
FAIL
Thrust block pre -pour
Rough -wire inspection
Underground rough
Function test
Underground hydro
Duct detectors/velocity
Flush
24 hr. battery test
Final
Sprinkler monitoring
SPRINKLER U.G.
Final
Thrust block pre -pour
j SPECIAL SUPPRESSION
Underground rough
Door fan test
Underground hydro
"Abort test
Flush
Mechanical shutdown
Final
Detector test
FIRE SPRINKLER
,0
Deluge/pre-action
Weld inspection
Final
Overhead rough piping
UST/AST TANK
Overhead hydro
Installation
UG flush / OK to connect
Removal
Main drain/inspect. Test 10450
Emergency shut off
High pile storage
Primary piping
In -rack sprinklers 040F
Secondary piping
Hose racks
Dispensers & shear valves
X
Final
Final
KITCHEN. -ROOD EXTINGUISHING
MISC. INSPECTION
Detectiog'System
Spray booths
Fun " n Test
Hood/duct extinguishing
Ga /Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hydrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
Final
Final for occupancy
Start Time: Finish Time:
5
Iliana Gutierrez
Subject: FIRE20-0561 TR36485-5 O/H ROUGH/HYDRO LOT 14
Location: 24478 MONTGOMERY WAY
Start: Tue 9/8/2020 11:00 AM
End: Tue 9/8/2020 11:30 AM
Recurrence: (none)
Organizer: Menifee OFM
Call Handling Mode 2: 2
Rep. Name: HECTOR
Phone#: 951-847-2908
Cell#:
Co. Name: FSS
CrossSt: TRIBUTE
HYDRANT SYSTEM
PASS
FAIL
FIRE ALARM
PASS
FAIL
Thrust block pre -pour
Rough -wire inspection
Underground rough
Function test
Underground hydro
Duct detectors/velocity
Flush
24 hr. battery test
Final
Sprinkler monitoring
SPRINKLER U.G.
Final
Thrust block pre -pour
SPECIAL SUPPRESSION
Underground rough
Door fan test
Underground hydro
Abort test
Flush
Mechanical shutdown
Final
Detector test
FIRE SPRINKLER
Deluge/pre-action
Weld inspection
Final
X
Overhead rough piping
UST/AST TANK
X
Overhead hydro
Installation
UG flush / OK to connect
Removal
Main drain/Inspect. Test
Emergency shut off
High pile storage
Primary piping
In -rack sprinklers
Secondary piping
Hose racks
Dispensers & shear valves
Final
Final
KITCHEN HOOD EXTINGUISHING
MISC. INSPECTION
Detection system
Spray booths
Function Test
Hood/duct extinguishing
Gas/Electrical shut-off
High pile rack storage
Nozzle model/placement
H.P. vents/access/corridors
Fire alarm connection
Tract access/hydrant verification
Final
Other:
SPRAY BOOTHS
KNOX SYSTEM
Installation
Building Knox box
Air flow test
Gate access Knox box/padlock
Mechanical interlock
BUILDING INSPECTIONS
Extinguishing system
T/I final
Fire alarm connection
Shell final
Final
Final for occupancy
Start
Time: Finish Time:
17