31701 BUCKEYE WY FIRE21-0261 CYPRESSIliana Gutierrez Subject: FIRE21-0261 TR30142 O/H ROUGH/HYDRO LOT 2 Location: 31701 BUCKEYE WAY Start: End: Recurrence: Organizer: Call Handling Mode 2 Rep. Name: RACHEL Phone#: 909-906-5921 Thu 6/17/2021 3:30 PM Thu 6/17/2021 4:00 PM (none) Steven Fox 2 Cell#: Co. Name l.rubsJi: l.Y t'KCJJ HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre -pour Rough -wire inspection Underground rough Function test Under round hydro Duct detectors/velocity Flush 24 hr. battery test Final Sprinkler monitoring SPRINKLER U.G. Final Thrust block pre -pour SPECIAL SUPPRESSION Underground rough Door fan test Underground hydro Abort test Flush Mechanical shutdown Final Detector test FIRE SPRINKLER Deluge/pre-action Weld inspection Final X Overhead rough piping UST/AST TANK X Overhead hydro Installation UG flush / OK to connect Removal Main drain/Inspect. Test Emergency shut off High pile storage Primary piping In -rack sprinklers Secondary piping Hose racks Dispensers & shear valves Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detection system Spray booths Function Test Hood/duct extinguishing Gas/Electrical shut-off High pile rack storage Nozzle model/placement H.P. vents/access/corridors Fire alarm connection Tract access/hvdrant verification Final Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: Start Time: Finish Time: L Iliana Gutierrez Subject: Location: Start: End: Recurrence: Organizer: Call Handling Mode 2: Rep. Name: Phone#: RACHEL FIRE21-0261 TR30142 SPK FINAL LOT 2 31701 BUCKEYE WAY Tue 8/17/2021 2:00 PM Tue 8/17/2021 2:30 PM (none) Steven Fox 2 909-906-5921 Cell#: Co. Name: KP Cr sSt: CYPRESS NORTH HYDRANT SYSTEM PASS FAIL FIRE ALARM PASS FAIL Thrust block pre -pour Rou h-wirOins ection Underground rough Function test Under round hydro Duct detectors/velocity Flush 24. hr. battery test Final rinkler monitoring SPRINKLER U.G. j Final Thrust block pre -pour SPECIAL SUPPRESSION Underground rough Door fan test Underground hydro Abort test Flush Mechanical shutdown Final _ et r test FIRE SPRINKLER e/ re -action Weld inspection Aal Overhead rough piping UST/AST TANK Overhead hydro Installation UG flush / OK to connect Removal Main drain/Inspect. Test Emergency shut off High pile storage Primary piping In-racksprinklers Secondary piping Hose racks Dispensers & shear valves X Final Final KITCHEN HOOD EXTINGUISHING MISC. INSPECTION Detectionsystem L. Spry booths Function Test Y Hood/duct extinguishing Gas/Electrical shut-off' High pile rack storage Nozzle model/pfacernent H.P. vents/access/corridors Fire alarm connection Tract access/hydrant verification Final 6 Other: SPRAY BOOTHS KNOX SYSTEM Installation Building Knox box Air flow test Gate access Knox box/padlock Mechanical interlock BUILDING INSPECTIONS Extinguishing system T/I final Fire alarm connection Shell final Final Final for occupancy Start Time: Finish Time: Start Time: Finish Time: 15