Loading...
939K- 28788 2/15/2005 EMWD Recycled Water 28787,88,89,90 Evans Rd,La Piedra Rd,Rim Creek Path,Bam i ESCONDIDO FREEWAY EASTE, RN NEWPORT ROAD MUNICIPAL -DI,5TRICTIA TR. 28788 is COUNTY OF RIVERSIDE, STA TE OF CALIFORNIA TR. 28790 LA PIEDRA ROAD RECYCLED WATER � TR. 28787 TR. 28789 PLANS RECYCLED WA T R NOT TRACT NO. 28787, 28788 128789 AND 128790 LA PIEDR4 ROAD )7- 227-2600E ES _ NO TI FI CA TIONS: I S1TE AL ACA LANE I ( SI TEo (VACATED) A. RECYCLED WATER LINE AND APPURTENANT CONSTRUCTION SHALL BE /N ACCORDANCE CONTRACTOR SHALL NOTIFY RIVERSIDE COUNTY TRANSPORTATION DEPARTMENT, WITH EMWD STANDARDS AND SPECIFICATIONS. CONSTRUCTION SECTION AT RIVERSIDE (951) 955-6885 AT LEAST 48 HOURS B. PRIOR TO CONSTRUCTION OF PIPELINE, CONTRACTOR SHALL EXPOSE EXISTING /N ADVANCE OF STARTING CONSTRUCTION. HOLLAND ROAD RECYCLED WATER SYSTEM AND VERIFYING ITS EXISTING ELEVATION AND LOCATION. ALSO, AT LEAST 48 HOURS PRIOR TO COMMENCING CONSTRUCTION, CONTRACTOR SHALL NOTIFY- C.C. ALL SERVICE CONNECTIONS SHALL BE AS NOTED AND LOCATED AS SHOWN ON THE VICINITY MAP PLANS, ADJUST AS NECESSARY TO MISS DRIVEWAYS. SERVICES SHALL BE INSTALLED /N B.D. A. EASTERN MUNICIPAL WATER DISTRICT, FIELD ENGINEERING DEPARTMENT ACCORDANCE WITH STANDARD DRAWINGS PA-3 AND PB-1. 1RACT X 28 ' 129 130 131 132 13' (951) 928-3777, EXT. 48JO ' B. UNDERGROUND SERVICE ALERT (USA) 1 (800) 227-2600 N.T.S. D. BLOW—OFFS SHALL BE INSTALLED IN ACCORDANCE WITH STANDARD DRAWING FA—1. SEC. 2, T. 6 S., R. 3 W. E. TEMPORARY BLOW-OFFS SHALL BE INSTALLED IN ACCORDANCE WITH STANDARD f21 f22 '9Tjy ';. 1 DRAWING PA-1. Y 8 A.R. f8 /�'�'_ DEPARTMENT RO F. AIR VALVES SHALL BE INSTALLED /N ACCORDANCE WITH STANDARD DRAWING PB-8, fen 127 A PP TYPE B. __ 67 2 ; THE RIVERSIDE C PARTMENT OF HEALT G. RECYCLED WATER SYSTEM PROFILE ELEVATIONS ARE TO CENTERLINE (CENTERGRADE) 3 OF PIPE. 118 BY. H. JOINT RESTR4/NERS, INSTEAD OF THRUST BLOCKS, SHALL BE USED ON ALL MAIN 4 h 117 118 LINE PIPE JOINTS WITHIN SPECIFIED LIMITS AND ALL JOINTS OF WATER APPURTENANCE 1f7 1f6 NO LATERALS OFF MAIN LINE, EMWD STANDARD DRAWING B-663. 5 19 SEP DISTANCE BETWEEN WATER & SEWER /MPROVEMEN ONFORM TO 1 lie 84 115 SIDE COUNTY STANDARD NO. 609 L ALL P.V.C. PIPE THROUGH 12" SHALL BE TYPE C-900, CLASS 150 EXCEPT WHERE NOTED OTHERWISE. PIPE SHALL CONFORM TO AWWA SPECIFICATIONS. 1f , J. FITTINGS FOR P.V.C. PIPE SHALL BE DUCTILE OR GRAY IRON. FITTINGS SHALL BE 115 62 r13� nlcT FLANGED, BOLTED MECHANICAL JOINTS, OR PUSH-ON JOINTS, AND SHALL BE CEMENT 12 MORTAR LINED AND TAR (SEAL) COATED PER EMWD STANDARDS AND SPECIFICATIONS. 8 ' ' ! 111 :q ESTIMA TE OF QUANTI TIES K. POLYETHYLENE ENCASEMENT- ALL DUCTILE OR GRAY IRON FITTINGS SHALL BE 87 POLYETHYLENE ENCASED AT THE TIME OF INSTALLATION PER EMWD STANDARDS AND RAMBLE W 06D 9_ ' •qy SPECIFICATIONS. CIRCLE o fo a 3f o, RECYCLED WA TER W 8" PVC C-900 CL150 WATER MAIN-------- 3,352 L.F. L. ALL NEW BURIED CONSTANT PRESSURE TRANSMISSION/DISTRIBUTION PIPING /N THE , W 11 12" PVC C-900 CL 150 WATER MAIN_______ 1,350 L.F. RECYCLED WATER SYSTEM, INCLUDING SERVICE LINES, VALVES AND OTHER V ` APPURTENANCES SHOULD EITHER BE COLORED PURPLE, PANATONE 522C, AND � 12 , ry 29 2" WATER SERVICE ASSY. (PA-3 & PB-1) ______ 8 EA EMBOSSED OR BE INTEGRALLY STAMPED/MARKED "CAUTION: RECYCLED WATER DO NOT 12'MA)DP `.W28 " •�„``' BACKFLOW PREVENTOR (6-597)_ __________ 8 EA. DRINK" OR BE INSTALLED WITH A PURPLE IDENTIFICATION TAPE, OR A PURPLE ._ , , ��PACT 28787 � 32 POLYETHYLENE VINYL WRAP, COLOR TO BE PANATONE 512C 13 � 8" R.S.G. VALVE ---------------------- 5 EA. 9 60 61 ' 12" R.S.G. VALVE ---------------------- 1 EA. 14 � 18 34 8" FLG'D CROSS ---------------------- 1 EA. ': 1" A.V. & A.R. ASSEMBLY (PB-8) ........... 4 EA. rn TIME LIMI TA TION 24 BLOW-OFF (FA 1) -------------------- 7 EA. FLAX LEAF DRIVE THE TIME LIMIT ON DRAWINGS APPROVAL SHALL BE SIX (6) s f8 17 16 ' 15 ' �� 8" 45' HxH ELBOW -------------------- 12 EA. MONTHS FROM THE DATE ON THE CERTIFICATION. IF CONSTRUCTION P3 y 37 8" ADAPTOR _________________________ 1 Bq HAS NOT COMMENCED WITHIN STATED TIME, EMWD REQUIRES . 38 12" ADAPTOR ------------------------ 3 EA. DRAWINGS TO BE REVIEWED BY THE DEVELOPERS / DESIGN 22 ENGINEER AND SUBMITTED TO EMWD FOR POSSIBLE CHANGES IN ' •� • 21 39 12 x8 REDUCER ---------------------- 1 EA. MASTER PLANNED SIZING AND CHANGES IN SPECIFICATIONS AND STANDARDS. 40 20 l 41 1 19 42 18 ss 109 111 112 I1J «u m17 57 --I 53 110 121 W tti1 45 0. Z$" 51 52 ' .R. 38 W 36 ` f5 *ACT 49 50 124 123 122 SEWER LEGEND Q.' N 14 416 4748 ��t QRIE �--1 f29 18 /27 f�' 12 AifCf�XED MN f2C�'�'' 37 Y G Cn 1.70 '4��„ ,ate. -. •mow. ..r. — J� — SEWER LATERAL EX OR PROP. BY OTHERS Ogq 131 : ..+. IRAD 80o — — EWER AWN EX PRA�718"SENf1P �� 13 ;: IAACT 8789 ��- " S OR PROP B?' OTHERS < I -- —C�— — SEWER AtIANHOLE EX. OR PROP. BY OTHERS PER TRACT 28787 7RACT#0.. 28787 - 12 Cl3xED Mh17f]P 4 .� oia .�rf- 6 5 3 L -- -� RECYCLED {/A TER LEGEND 7loo r T PAPM 12'AN ID? P& TRACT 28787 9 P1Pq D 30 IMIIER RECYCLED WATER MAIN 10 E ,�+ PL�/P 1R�1CT 28789 R.S.G. VALVE (RESTR,4tNED)(HxH) _ I1 l' A.V. & A.R. ASSEMBLY (PB-8) TYPE "BFt • w.. PIES �CT 6' BL0WOFF ASSEMBLY (PA-1) '�" VITA RESTRAINED END PLUG PIJP IIPACT 8789 -- + PROP. 6" FIRE HYDRANT V 8 Aft — 2' SERVICE CONNECTION W/ ME rR ga R.S.G. VALVE (RESMINED)(FxH) WA MHA77W TRACT N0. 28794 \ 28787��1UREr — — - WATER MAIN EX. OR PROP. BY OTHERS T ❑B SACKFLOW PREVENTOR' I N D E X M A P S CA L E. 1" = 150' 150 75 150 300 450 - -- --- IMPLEMENTING RECYCLED WATER FACILITIES GRAPHIC SCALE: 1'=150' PROP. 30" WATER ON LA PIEDRA RD. PER TR. 28789 No. C51394 EXPIRES �. 6-30-06 PRESSURE ZONE i 627 TP O ZOO 9q _ 0zi - OZolot — �72��a2939 k PROJECT BENCHMARK RECYCLED WATER APPROVED BY: REVISIONS: SEAL-COUNTY PREPARED BY: EASTERN MUNI IPAL WATER DISTRICT � COUNTY U N TY 0� RIVERSIDE I.D. U-3sjU--35 Underground 2.2 MILES SOUTH ALONG MURRIETA RD. FROM THE J . S.A.41/33 Service Alert CATHOLIC CHURCH IN SUN CITY 0. 15 Mt. FROM THE V� � /a 7�Sf a I'�( ._.., INT. OF MURRIETA RD. AND NEWPORT RD., ��� P. Ony JIMMY C N R.C.E. cst394 �e�ys ,� _ s•�ynr �- W.O. 10825 Call: TOLL FREE 246 CIVIL ENGINEER OF SUBDIVISIONS DATE:' 'y4y DATE: E0'744'O* REGISTRATION EXPIRES 6-30-06 98�4 EASTERN MUNICIPAL WATER DISTRICT E/O MURRIETA RD., 115 FT. S.E./0 THE MOST E LY. ca 28789 AND 28790 C.O. INITIAL DATE APPROVED BY: TRACT NO. 28787 28788 1 -800 OF TWO 36" EUCALYPTUS TREES TOP OF A � No. 33950 F � COOOD. 23-f.-3b 3'X5'X6' ROCK /N THE MOUND OF ROCK PROJECT ENG. A.GI.A. (o I i 5/o� Exp. 6/30/06 RECYCLED WATER 4'X15'X30' SET A BRASS DISK DATE; 1970 APPROVALS INSEPECTIONq� CIVIC �Q SCALE: BENCH MARK: TITLE SHEET �C SHT. 1 OF 6 TWO WORKING DAYS BEFORE YOU DIG WTR. OPERATIONS IVERSI COUN SEE AT LEFT ELEVATION. 1439.662 Q` CA��E '0 6 _ ' O TR TATI �g I o j2.f/o•f DATE: JUNE 2004 INDEX MAP SEWER OPERATIONS DATE: P �;A�t ��tP�� �a7r7 9 1 FiNA! I-1�G1.3-�R- �.3Fr'nl�l�-.N .3-28-(i.5' SFWFt ,x� T��R`.kr C� ii sF s� A i�' '�, r: �','R 5HT% dw- i i t ESCONDIDO FREEWAY STERN Al UNI CIPA L W1 A TER DISTRICT ' NEWPORT ROAD TR. 28788 COUNTY OF RIVERSIDE, 28790 CALIFORNIACALI�'ORNIA EA LA PIEDRA ROAD RECYCLED WATER IMPRO VEMEN T PLANS TR 28787 TR 28789 TRA CT NO. 128 78 7 ,28 788, 78 AND ,28 790 � ��� RQ�D 21 RECYCLED WATER NQTES , PROJECT & AWN LAB NQTIf ICA TIO . SITE o � A. RECYCLED WATER LINE AND APPURTENANT CONSTRUCRON SHALL BE /N ACCORDANCE CONTRACTOR SHALL NOTIFY RIVERSIDE COUNTY TRANSPORTATION DEPARTMENT, I I I WITH EA WD STANDARDS AND SPECIFICATIONS CONSTRUCTION SECTION AT RIVERSIDE' (95 f) 955-658,5 AT LEAST 48 HOURS � B. PRIOR TO CONSTRUCTION OF PIPELINE, CONTRACTOR SHALL EXPOSE EXISTING IN ADVANCE OF STAR77NG CONSTRUCTION. HOLLAND ROAD RECYCLED WATER SYSTEM AND VER1r6NG ITS EXISTING ELEVATION AND LOCATION. ALSO, AT LEAST 48 HOURS PRIOR TO COMMENCING CONSTRUCTION, CONTRAACTOR SHALL NOTIFY f f T MAP C. ALL SERVICE CONNECTIONS SHALL 6E AS NOTED AND LOCATED AS SHOWN ON THEVICIl Y It Y PLANS, ADJUST AS NECESSARY TO MISS DRIVEWAYS. SERVICES SHALL BE INSTALLED IN dt0 7R�C7- A t19 A. EASTERN MUNICIPAL WATER DISTRICT, FIELD ENGINEERING DEPARTMENT ACCORDANCE WITH STANDARD DRAWINGS PA-3 AND PS-1. (951) 928-3777, EXT. 4830 r N.T.S. B. UNDERGROUND SERVICE ALERT (USA) 1 (800) 227-2600 D. BLOW—OFFS SHALL BE INSTALLED IN ACCORDANCE W17H STANDARD DRAWING PA-1. SEC. 2, T 6 $,, R. ,j W. E. TEMPORARY BLOW—OFFS ShG4L1 BE INSTALLED /N ACCORDANCE WITH STANDARDTp x DRAWING PA-1. - .- th1 1 F AIR 1� s *AA[ PARTM-ENT APPR A VALVES SHALL BE INSTALLED /N ACCORDANCE WITH STANDARD DRAWING P6-8, ::+ 1 127 1� _ TYPE "B." 1f9. . 67 2 THE RIVERSIDE PARTMENT OF HEAL G. RECYCLED WATER SYSTEM PROFILE ELEVATIONS ARE TO CENTERLINE (CENTERGR4DE) 3 OF PIPE. 11B dWBY H. JOINT RESTRAINERS, INSTEAD OF THRUST BLOCKS, SHALL BE USED ON ALL MAIN # 1t7 1t8 t LINE PIPE JOINTS W/THJN SPECIFIED LIMITS AND; ALL JOINTS OF WATER APPURTENANCE 117415 ... 1� 1� LATERALS OFF MAIN LINE, EM*V STANDARD DRAWING B-663. � i r g ` � ¢�,i' � f" ' 113 DISTANCE �TN'EEN WATER � SEWER /MPROV VEN ONFORM TO 4 115 fDE COUNTY STANDARD NO. 609 I. ALL P.V.C. PIPE THROUGH 12" SHALL BE TYPE C-900, CLASS 150 EXCEPT WHERE N07EDD OTHERWISE. PIPE SHALL CONFORM TO AiWWA SPECIFICATIONS J. FITTINGS FOR P.V.C. PIPE SHALL B Aw E DUCTILE OR GRAY IRON. FITTINGS SHALL BE115 r f, 7 FLANGED, BOLTED MECHANICAL JOINTS, OR PUSH—ON JOINTS, AND SHALL BE CEMENT � �a 113 a� �°=�', ff1 112, MORTAR LINED AND TAR (SEAL) COATED PER EMWD STANDARDS AND SPECIFICATIONS. r i e � , ,, ESTIMATE OF OUANT/TIES K. POLYETHYLENE ENCASEMENT ALL DUCTILE OR GRAY IRON FITTINGS SHALL BE dEri y � . POLYETHYLENE ENCASED AT THE 77ME OF INSTALLA77ON PER EMWD STANDARDS AND RECYCLED WATER SPECIFICATIONS N ------ F. C C 900 CL 150 WATER MAIN 3,352 L F L. ALL NEW BURIED CONSTANT PRESSURE 7RANSMISSION/DISTRIBU7I0N PIPING /N THE " _ , . , . 1 J , ,3p • 12 PVC C-900 CL 150 WATER MAIN------- 1,350 L.F. RECYCLED WATER SYSTEM, INCLUDING SERVICE LIVES, VALVES AND OTHER {, 1 " APPURTENANCES SHOULD ETHER BE COLORED PURPLE, PANATONE 522C, AND — ;, r ?9 .� 2 WATER SERVICE ASSY. (PA-3 do PB-1) -- _ 8 EA. EMBOSSED OR BE INTEGRALLY STAMPED/MARKED "CAUTION: RECYCLED WATER DO NOT 1? , 12"•TIER 84CKFLOW PREVENTOR (B ------------ 8 DRINK" OR BE INSTALLED WITH A PURPLE IDENTInG477ON TAPE, OR A PURPLE u 32 ` ?d POLYETHYLENE VINYL WRAP, COLOR TO BE PANATONE 512C 8" R.S.G. VALVE ---------------------- 5 EA. 9 �9 61 R.S.G. ---------------------- r 2 5 ' 14 � 12" R S G VALVE f EA i 8'" FLG'D CROSS ---------------------- x _ r ASSEMBLY ( B ) _ — r" A.V. A.R. AS P 8 ----------- 4 EA. TIME UMI TA TION BLOW ( A- ) ------------------- . I�LiAJC LEAF LRIt/E BLO P 1 — 7 F4 r K .. 24 I n THE TIME LIMIT ON DRAWINGS APPROVAL SHALL BE SIX (6) 4 8" 45' H �' JB 17 16 13 ' xH ELBOW 12 EA. MONTHS FROM THE DATE ON THE CERTIFICATION. IF CONSTRUCTION 2J 37 8" ADAPTOR ------------------------- 1 FA. HAS NOT COMMENCED WITHIN STATED TIME, EMWD REOUIRES =: _._ 12" ADAPTOR ------------------------ 3 EA. DRAWINGS TO BE REVIEWED BY THE DEVELOPERS / DESIGN 22 -- TOR ENGINEER AND SUBMITTED TO EMWO FOR POS98LE CHANGES IN ' � � " " .3I! 12 x8 REDUCER ---------------------- 1 EA. A44STER PLANNED SIZING AND CHANGES /N SPECIFICATIONS AND STANDARDS t .. #1 1 19 42 40112 jlie . mt7 .:, 411 JV : � eQ ,3f6jr 1 . � 5 5i2 r LEG r n A.M. t AR. 1S C 12# 12,7 L II R LL V G ND O ._ � rZ s 1�� 't 1!!� 117 1� t?5 t 1?2 ' dtQ .> LA7€RAL FCC OR PROP BY OTHERS SENER OR BY R 13 ; -Mir A�4N�il ETC PROP OTHERS P![q�D SHIP SfMrER �RNVLE EX. OR PIRbP. BY OTHERS 5 pff mwr�7 AKA 28hY712 1 '�. Sam r BMW .�1 r 3 i k Y- o 5 7 f , R CYCLE., :OVA T ova _ TER LEGEND '9�/� ♦ '" AN Awr�7 � �,.• ''� � jr mvp RECYCLED W47ER AWN R&G VALVE (mocr Am )(HxH) '9C'l�O `Y .,. ,7! , "�'"' '" ..► 'I 1"A.v. & A R AssEA�LY (Pe-8) rmE 19* ti. 1RACtq s" etoWOFF ASSEMBLY (PA-1) END PLUG .. ETA RI STRAMIED j� _ V� 2" SERME CONNECTION W/ METER �19 ,_ .• t0' R.S.G. VALW (RET1Ri WDXFxH) 7&h4)7W 7RACT#0.. AM4 � 7 � — — - WATER AWN Ex. OR PROP: BY OTt1ERS s� T © B4CKFLOW PREK OR' N D E X M A P S C A L E 1'v 150' ISO 75 1 4 IMPLEMENTING RECYCLED WA TER FA CIL.I TIES GRAPHIC SCALE: 1'=150' PROP. 30„ WATER ON LA PIEDRA RD. PER TR. 28789 No. C513" DCpm 6-30-06 PRESSURE ZONE 1627 TP OZ.oUgq - OZloo - 02olot -- 42o�a2k. pAy"T aENct K RECYCLED WATER APPROVED BY: REVISIONS: SEAL,—COUNTY PREPARED BY: I.D. U-36/U-35 Underground 2.2 MILES SOUTH ALONG MURRIETA RD. FROM 7HE EASTE N WIUNI�IPAL WATER DISTRICT COUNTY OF RIVERSIDE o � S.A.41/33 Service Alert CATHOLIC CHURCH IN SUN CI7Y 0.15 MI. FROM THE � � �o�i o AlJDW _ � Cali: TOLL FREE /NT. OF MURRIETA RD. AND NEWPORT RD., 246 CIVIL ENGINEER OF SUBDIVISIONS DATE: ``� DATE: !o-,�,c— TUTU ESE ���� SLOW �� EASTERN MUNICIPAL WATER DISTRICT W.O. 10825 E/0 MURR/ETA RD. 115 FT. S E./0 THE MOST E LY. .� 1 —800 OF TWO 36 EUCALYPTUS TREES TOP OF A - INITIAL DATE Nc 33950 APPROVED BY: �? TRACT N0. 28787, 28788, 28789 AND 28790 C.O. 2 2 7-2 6 0 0 3 X5'X6' ROCK /N THE MOUND OF ROCK PROJECT ENG. A.U.A• 10116101 Exp. 6/30/06 RECYCLED WATER COOOD. 23 —3L 4 X15 X30 SET A BRASS DISK DATE; 1970 ,APPROVALS INSEPECTION � 9% BENCH MARK: TITLE SHEET & x TWO WORKING DAYS BEFORE YOU DIG WTR. OPERATIONS VERSI CDIJN SHT. OF ELEVATION: 1439.662 SEWER OPERATIONS DAB: R• : TA ;�?,$ lojZ�/00f DATE: DUNE 2004 SEE AT LEFT INDEX MAP Prnia=rt F"ilac 3—,d—n-d\ Prni4,mrf F-ila+.,\.P7n1.?\ FINAIFN(,\.3-2R—O,5FlAlALFNG'\.,3— 8—n.3\ SFWF ;W4TFR\RI=C.iAIMF0 i/ATFR\F•.?r-(W7W SHT --ff