Loading...
PMT18-05569 City of Menifee Permit No.: PMT18-05569 29714 HAUN RD. MENIFEE, CA 92586 Type: Residential Electrical MENIFEE MENIFEE Date Issued: 11/27/2018 PERMIT Site Address: 30454 VILLAGE KNOLL DR, MENIFEE, Parcel Number: CA 92584 Construction Cost: $5,931.52 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM,7 PANELS, 2.135 KW Work: THE VILLAGE TR 37179 LOT 107 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN KIMBERLY CURTIS Applicant Phone: 9493891756 SAMANTHA MAZELLA License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN KIMBERLY CURTIS ALISO VIEJO, CA 92656 Fee Description QQtt( Amount 1$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION "°' `'' MENIFEE h3U'ILUFtuG& A'-t I'f DATE: 10/24/2018 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER TYPE: COMMERCIAL RESIDENTIAL MULTI-FAMILY MOBILE HOME POOL/SPA C. SIGN SUBTYPE: C. ADDITION ALTERATION DEMOLITION ELECTRICAL MECHANICAv3 Ily O e fee Li uilding D pt, NEW PLUMBING RE-ROOF NUMBER OF SQUARES NOV DESCRIPTION OF WORK Solar Permit-The Villa e Ph 4 N0 Y 2 2 18 Plan T e: JaOrp KW: A, 13,S PCS: Master Solar Permit t F`MT1 7-043,^ M11 ed PROJECT ADDRESS 30454 yi1taae- kneC.L rx\yC. ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT TRACT 37171 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? :.• YES NO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LLIIC NUMBER 728102 LICENSE CLASSIFICATION A&B TE VALUATION$ J-- 3/ SO,FT L SQ FT !J APPLICANT'S SIGNATURE DATE 6 7l ly CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ^- ACCEPTED BY: CITY OF MEN IFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ICY, INVOICE TOTAL �,U0 GREEN '— SMIP OWNER BUILDER VERIFIED YES :` NO DRIVERS LICENSE# NOTARIZED LETTER YES NO City of Menifee Building & Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 "v o, www.cityofinenifee.us MENIFEE s. d SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.135 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 7 PCS. BOVIET BVM6610M (305W) BUYER: INVERTER 7 PCS. ENPHASE IQ7-60-2-US ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION _ ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 7 NA NA NA BUYER:--- TILT 18° NA' NA' NA- DATE: AZIMUTH 90° NA* NA° NA* — - City of Menifee Building Dept. ' NOV 2 1 2018 Received Y z Q= K Q Q J _ lL o, O O NJ N N SOLADECK WIRE PV AC DISCONNECT TRANSITION BOX EXTERIOR-GARAGE (UNDER ARRAY) UTILITY METER& , MAIN SERVICE PANEL (VERIFIED BY BUILDER) = AC COMBINER BOX CITY OF MENIFEE BUILDING AND SAFETY DEPARTMENT PLAN APPROVAL REVIEWED BY ( \�\Qx�yq) DATE NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOIApproval of these plans shall not be construed to be a permit for,or an n I approval of,any violation of any provisions of the federal,state or city I®V PLANpAgions and ordinances. This set of apjpvepW mQ�kept on the ORIj Tt1:0 htii completion. LOT# 107 :18.09.05 MENIFEE TOWN CENTER LE REVIEWED BY:STEVE FURR DATE:18.09.06 980 NA,CAI 2 DRIVE,#302 REV.# BY DATE DESCRIPTION SOLAR 8 D A 4 CLUSTER CORONA,CA 92879 sown DWG TITLE: PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard Denver,CO 80204 INDIVIDUAL 30454 VILLAGE KNOLL DRIVE 303.447.0300 PLOT PLAN I 1/16` = I'-0" MENIFEE, CA SYSTEM LAYOUT MODULE SPECIFICATIONS AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL LOCATION MENIFEE,CA INVERTER MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAx) ASHRAE 2% °C 37 INVERTER MODEL INVERTER SPEC 107-60-2-US TEMP,AMBIENT LOW(THIN) ASHRAE EXTREME MIN °C -2 INVERTER MAX POWER(WAC MAX) INVERTER SPEC WATTS(AC) 350 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INVERTER INPUT VOLTAGE(VOC MAX) INVERTER SPEC VOLTS(DC) 48 TEMP.DETLA LOW(TDELTA) TMIN-TTEST °C -27 INVERTER OUTPUT VOLTAGE(VAC MOM) INVERTER SPEC VOLTS(AC) 240 MODULE MANUFACTURER MODULE SPEC SOVIET INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MODULE PART NUMBER MODULE SPEC BVM661OM-305 INVERTER OUTPUT CURRENT(IAC) INVERTER SPEC AMPS(AC) 1.00 MODULE POWER STC(P) MODULE SPEC WATTS(DC) 305 INVERTER PHASE QUANTITY INVERTER SPEC PHASE I MODULE OPERATING VOLTAGE(VHF) MODULE SPEC VOLTS(DC) 32.4 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MODULE OPEN CIRCUT VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 39.9 INVERTER GROUNDING INVERTER SPEC ISOLATED MODULE COEF.VOLT/TEMP(COEFF) MODULE SPEC V/C° -0.124 INVERTER QTY.MAX PER BRANCH CIRCUIT MODULE OTYBC QTY 7 MODULE MAX VOLTAGE(VMAXMOD) (Voc+(To°COEFF)) VOLTS(DC) 43.25 BRANCH CIRCUIT OUTPUT(IMAXII0 (IAC°MODULE OTYsc) AMPS(AC) 7.00 MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU 9.42 INVERTER OTY.TOTAL MODULE OTYT OTY 7 MODULE SHORT CIRCUIT CURRENT(ISC) MODULE SPEC AMPS(DC) 9.94 TOTAL SYSTEM OUTPUT(IMAXTS) (IAC°MODULE OTYT) AMPS(AC) 7.00 MODULE MAXIMUM CURRENT(IMAX) (ISC°1.25) AMPS(DC) 12.43 MINIMUM AMPACITY REO'D.PER NEC (IMAX°1.25) AMPS(DC) 15.53 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 20 CONDUCTOR SIZING CALCULATIONS CONDUCTOR SCHEDULE 1)CONDITION OF USE(COU): (AMPACITY"TEMP. DERATE°FILL DERATE)vs:REO'D OMAx) KEY CONDUCTORS CU/AL TYPE LOCATION TRADE 1#12 ENPHASE Q CABLE,I-#6G, UL3003,OG 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REQ'D,(IMAX y 1,25) A FREE AIR CU CABLE ARRAY SOLAR CALC. AMPACITY TEMP. FILL OCD USED B 3-#10-,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR KEY SIZE CU/AL INSULATION TYPE W/O DERATES DERATE DERATE RESULT(A) REO'D(A) (A) C 3410,I410 EGC CU NM-B(ROMEX) INTERIOR SOLAR A #12 CU THWN-2 COU 30 0.76 1.00 22.80 7.00 TERM 25 25 8.75 20 "NEUTRAL CAPPED AND NOT USED B #10 CU NM-B COU 40 0.91 1.00 36.40 7.00 INTERCONNECTION CALCULATIONS TERM 35 35 8.75 20 TE1 UNIT PANE- L #10 CU NM-B COU 40 0.91 1.00 36.40 7.00 PANEL MANUFACTURER CUTLER-HAMMER TERM 35 35 8.75 20 MINIMUM BUS RATING AMPS 200 ELECTRICAL EQUIPMENT SCHEDULE IMAIN DISCONNECT AMPS 200 ALLOWED PV PER NEC AMPS 40 KEY OTY MANUFACTURER MODEL NOTES TRADE PV OCPD DEVICE USED AMPS 20 1 7 SOVIET BVM661OM-305 PV MODULE SOLAR I.00A X 7(MODS)= 7.00A OF CURRENT 2 7 ENPHASE 107-60-2-US PVINVERTER SOLAR 7.00A X 1.25= 8.75A 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF J-BOX,NEMA 3R,OTY TO VARY SOLAR TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER 4 1 ENPHASE IQ ENVOY ENV-IOAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-2 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I x 2OA-2P,I X 5A-IP SOLAR 7 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 8 1 CUTLER HAMMER TBD PV BREAKER,I X20A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. O 10 11 ITBD TSD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC. V III TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. O O O 4 7O SA/IP 00 © 20A/2P 4 2OA/2P O N 4 4 " IG I G G A B C ROOF�EXTERIOR-GARAGE-GARAGE ELECTRICAL DIAGRAM 2.135KW LOT#107 LENNAORIGINAL BY:CHRISTINE MARTINI DATE:18.09.05 MENIFEE TOWN CENTER 980 MO: REVIEWED BY:STEVE PURR DATE:18.09.06 980 NA, CAI 2 DRIVE,#302 REV.# BY DATE DESCRIPTION namaSGe DA 4 CLUSTER CORONA, CA 92879 1�p SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard Denver,CO 80204 INDIVIDUAL 30454 VILLAGE KNOLL DRIVE 303.447.0300 PLOT PLAN 2 NTS MENIFEE, CA ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE IRON RIDGE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE FLUSH MOUNT INSTALLATION 2016 EDITION AND FLASHFOOT2 INSTALLATION 2018 EDITION. 7)UFO MID CLAMPS REQUIRE A THREE EIGHTS INCH 3/8'SPACE BETWEEN PV MODULES. IRONRIDGE RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 9)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING (COMPOSITION TO TILE)WILL BE A MINIMUM OF 3". 10)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. II)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 12)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. BUILDER/ROOFER- 13)SHINGLE ROOF SYSTEM INCLUDING SHINGLES,UNDERLAYMENT,AND FLASHING DETAILS TO BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS AND NRCA BEST PRACTICES. 14)26 GA. INTERLOCKING FLASHING "SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APPROVED PRIOR TO PV SYSTEM INSTALLATION. 15)INSTALL SIDE WALL CAP AT TOP OF EACH SIDE WALL. 16)DO NOT STRIP TAPERED TRANSITION FOR WATER FLOW. TRANSITION MUST BE OF A POSITIVE SLOPE. ELECTRICAL NOTES: GENERAL 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE INVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR 8)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 9)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 10)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 11)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 12)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 13)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122 14)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING, OR MANUFACTURER'S RECOMMENDATIONS. SIGNAGE 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. 21) INTERCONNECTION BREAKER TO BE LOCATED OPPOSITE MAIN BREAKER. ORIGINAL BY:CHRISTINE MARTINI DATE18.09.05 MEN FEE TOWN CENTER 980 MOLENNA : REVIEWED BY:STEVE FURR DATE18.09.06 CORONA,CA I9 87TO 91VE,#302 REV.# BY DATE DESCRIPTION namasGB DA 4 CLUSTER SOLAR DWG TITLE: 0 PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard INDIVIDUAL Denver,CO 80204 30454 VILLAGE KNOLL DRIVE 303.447.0300 PLOT PLAN 3 NTS NOTES MENIFEE,CA CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE PV AC DISCONNECT TRANSITION BOX EXTERIOR - GARAGE (UNDER ARRAY) UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 7.00A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI DATE:18.09.05 LENMENIFEE TOWN CENTER 980 MO: REVIEWED BY:STEVE FURR DATE:18.09.06 CORONA,O CA I9 8D91VE, #302 REV.# BY DATE DESCRIPTION • namast� DA 4 CLUSTERSOLAR DWG TITLE: PAGE #: SCALE: SITE LOCATION: 888 Federal Boulevard Denvver,er,CO 80204 INDIVIDUAL 30454 VILLAGE KNOLL DRIVE 303.447.0300 PLOT PLAN 4 NTS MENIFEE, CA PLACARDS