PMT18-05561 City of Menifee Permit No.: PMT18-05561
29714 HAUN RD. Type: Residential Electrical
MENIFEE, CA 92586
MENIFEE MENIFEE Date Issued: 11/27/2018
PERMIT
Site Address: 27484 KOBUK VALLEY DR, MENIFEE, CA Parcel Number:
92585 Construction Cost: $9,691.68
Existing Use: Proposed Use:
Description of ROOF MOUNTED SOLAR SYSTEM, 12 PANELS, 3.660 KW, PLAN 3105
Work: CHELSEA TR 34406-6
LOT 65
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN KIMBERLY CURTIS
Applicant Phone: 9493891756
SAMANTHA MAZELLA License Number: 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN KIMBERLY CURTIS
ALISO VIEJO, CA 92656
Fee Description QQt[ Amount($)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE
DATE: 11/19/2018 PERMIT/PLAN CHECK NUMBER 1
PLANNING CASE NUMBER
TYPE: COMMERCIAL RESIDENTIAL MULTI-FAMILY MOBILE HOME POOL/SPA SIGN
SUBTYPE: ADDITION ALTERATION DEMOLITION ELECTRICAL MECHANICAL
NEW PLUMBING RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Chelsea @ Heritage Lake
Plan Type: 1105 KW: I G G o PCs: a Master Solar Permit#: PMT 5 6 Z
PROJECT ADDRESS 15eb14k Dri1r- ZIP 92585
Ult OT Meni ee
ASSESSOR'S PARCEL NUMBER LOT 65 TRACT @C- be t.
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella eecaived
APPLICANT NAME Lennar Homes f California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? YES NO
BUSINESS NAME
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION $ %b Qj . 61 So.FT L SQ FT
APPLICANT'S SIGNATURE DATE
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE
INVOICE TOTAL GREEN 1 - SMIP
OWNER BUILDER VERIFIED YES +:::' NO DRIVERS LICENSE# NOTARIZED LETTER YES - NO
City of Menifee Building & Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777
www.cityofinenifee.us
ENIF
_,�STEM I FORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE .660 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 12 PCS.1 BOVIET 13VM6610M (305W) BUYER:
INVERTER 12 PCS.1 ENPHASE 107-60-2-US
ROOF TYPE CONC. TILE DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 12 NA NA NA BUYER:
TILT 27° NA' NA* NA'
DATE:
AZIMUTH 101° NA' NA- NAG
City of Menifee
Building Dept.
NOV 2 1 2018
C002
eceive
__
a
M
N
PV AC DISCONNECT
EXTERIOR-GARAGE
y UTILITY METER&
MAIN SERVICE PANEL
NEMA 3R JUNCTION BOX (VERIFIED BY BUILDER)
(-I'OUTSIDE
AC COMBINER BOX
CITY OF MENI
BUILDING AN FETY DEPARTMENT
PLAN APPROVAL
REVIEWED BY 11
DATE
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
Approval of these plans shall not be construed to be a permit for,or an
N
approval of,any violation of any provisions of the federal,state or city
regulations and ordinances. This set of approved plans must be kept on the
PLAN 3105 jobsite wil=pIgtion. ELEVATION D-RIGHT
ORIENTATIO 4 2 LOT#65
LENNAR: ORIGINAL BY:CHRISTINE MARTINI DATE:18.10.31
CHELSEA AT 980 MONTECITO DRIVE,*302 REVIEWED BY:STEVE FURR DATE:18.11.01
HERITAGE LAKE CORONA,CA 92879 REV.# BY DATE DESCRIPTION OLARsti�
DWG TITLE: PAGE # SCALE: SITE LOCATION: 888 Federal Boulevard
INDIVIDUAL Denver, 0204
27484 KOBUK VALLEY DRIVE 303.447.0300
PLOT PLAN 1 1/16"=I'-0" MENIFEE,CA
SYSTEM LAYOUT
MODULE SPECIFICATIONS AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS
ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL
LOCATION MENIFEE,CA INVERTER MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAx) ASHRAE 2% °C 37 INVERTER MODEL INVERTER SPEC 1Q7-60-2-US
TEMP,AMBIENT LOW(TMIN) ASHRAE EXTREME MIN °C -2 INVERTER MAX POWER(WAC MAX) INVERTER SPEC WATTS(AC) 350
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INVERTER INPUT VOLTAGE(VOC MAX) INVERTER SPEC VOLTS(DC) 48
TEMP.DETLA LOW(TDELTA) TMIN-TTEST °C -27 INVERTER OUTPUT VOLTAGE(VAc NOM) INVERTER SPEC VOLTS(AC) 240
MODULE MANUFACTURER MODULE SPEC SOVIET INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MODULE PART NUMBER MODULE SPEC BVM661OM-305 INVERTER OUTPUT CURRENT(IAC) INVERTER SPEC AMPS(AC) 1.00
MODULE POWER STC(P) MODULE SPEC WATTS(DC) 305 INVERTER PHASE QUANTITY INVERTER SPEC PHASE I
MODULE OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 32.4 COMPLIANCE INVERTER SPEC UL1741/IEEEi547
MODULE OPEN CIRCUIT VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 39.9 INVERTER GROUNDING INVERTER SPEC ISOLATED
MODULE COEF.VOLT/TEMP(COEFF) MODULE SPEC V/C° -0.124 INVERTER OTY.MAX PER BRANCH CIRCUIT MODULE OTYBc OTY 12
MODULE MAX VOLTAGE(VMAXMOD) (Voc+(TD•COEFF)) VOLTS(DC) 43.25 BRANCH CIRCUIT OUTPUT(IMAXBC) (IAc*MODULE OTYsc) AMPS(AC) 12.00
MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 9.42 INVERTER OTY.TOTAL MODULE OTYT QTY 12
MODULE SHORT CIRCUIT CURRENT(ISC) MODULE SPEC AMPS(DC) 9.94 TOTAL SYSTEM OUTPUT(IMAXTS) (IAc*MODULE OTYT) AMPS(AC) 12.00
MODULE MAXIMUM CURRENT(IMAX) Osc*1.25) AMPS(DC) 12.43
MINIMUM AMPACITY REO'D.PER NEC (IMAX*1.25) AMPS(DC) 15.53
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 20
CONDUCTOR SIZING CALCULATIONS CONDUCTOR SCHEDULE
1)CONDITION OF USE(COU): (AMPACITY*TEMP.DERATE*FILL DERATE)vs. REO'D OMAX) KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs. REO'D,(IMAX* 1.25) A 1 FREE AIR#12 ENPHASE 0 CABLE,1-#6G, CU CABLE UL3003,DG ARRAY SOLAR
CALC. AMPACITY TEMP. FILL OCD USED B 3-#10*,1' -#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
KEY SIZE CU/AL INSULATION TYPE W/O DERATES DERATE DERATE RESULT(A) REOD(A) (A)
C 3-#10,I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
A #12 CU THWN-2 COU 30 0.76 1.00 22.80 12.00
*NEUTRAL CAPPED AND NOT USED
TERM 25 25 15.00 20
B #10 CU NM-B Cou 40 0.91 1.00 36.40 12.00 INTERCONNECTION CALCULATIONS
TERM 35 35 15.00 20
ITEM UNIT PANEL
C #10 CU NM-B COU 40 0.91 1.00 36.40 12.00
PANEL MANUFACTURER CUTLER-HAMMER
TERM 35 35 15.00 20
MINIMUM BUS RATING AMPS 200
ELECTRICAL EQUIPMENT SCHEDULE MAIN DISCONNECT AMPS 200
ALLOWED PV PER NEC AMPS 40
KEY 0TY MANUFACTURER MODEL NOTES TRADE
PV OCPD DEVICE USED AMPS 20
12 SOVIET BVM6610M-305 PV MODULE SOLAR
I.00A X 12(MODS)= 12.00A OF CURRENT
2 12 ENPHASE 107-60-2-US PVINVERTER SOLAR
12.00A x 1.25= IS.00A
3 1 TBD TBD PV ROOF J-BOX,NEMA 3R,OTY TO VARY SOLAR TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER
4 I ENPHASE 10 ENVOY ENV-IOAMI-240 PV DATA MONITOR,240V SOLAR
5 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR
6 1 ENPHASE TIED PV BREAKER,I x 20A-2P,I X 5A-IP SOLAR
7 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
8 1 CUTLER HAMMER TBD PV BREAKER,1 X20A-2P,RATING MAY VARY SOLAR 10
9 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. m
10 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC.
II 11 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. - O
OI
4 7O
5AAP O
O O I 20A/2P
0 2° L
IN
A g C C = II
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 3.660KW
LOT#65
ORIGINAL BY:CHRISTINE MARTINI DATE:18.10.31
LENNAR:
CHELSEA REVIEWED BY:STEVE FURR DATE:18.11.01 namastg
980 MONTECITO DRIVE,#302
HERITAGE LAKE CORONA, CA 92879 REV.# BY DATE I DESCRIPTION SOLAR
888 Federal Boulevard
DWG TITLE: PAGE#: SCALE: SITE LOCATION: Denver,CO 80204
INDIVIDUAL 27484 KOBUK VALLEY DRIVE 303.447.0300
PLOT PLAN 2 NTS MENIFEE,CA
ELECTRICAL
INSTALLATION NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. (SEE FIGURE 1)
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)ROOFTOP JUNCTION BOX WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. ALL PENETRATION ASSEMBLIES WILL BE INSTALLED PER
MANUFACTURERS' INSTRUCTIONS AND WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE TILE ROOF SURFACE.
6)THE IRONRIDGE XR RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE IRONRIDGE XR CODE-COMPLIANT INSTALLATION MANUAL
7)IRONRIDGE TOP CLAMPS REQUIRE A 0.37 INCH SPACE BETWEEN PV MODULES. IF UFO END CLAMP IS USED,XR LIGHT RAILS MUST EXTEND ONE INCHES(I")BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)IRONRIDGE XR REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 100'.
ELECTRICAL NOTES:
GENERAL
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90oC RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE INVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR
8)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730.
9)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
10)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
11)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
12)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
13)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122
14)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
SIGNAGE
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
21) INTERCONNECTION BREAKER TO BE LOCATED OPPOSITE MAIN BREAKER.
LENNAR: ORIGINAL BY:CHRISTINE MARTINI DATEi8.10.31
CHELSEA AT980 REVIEWED BY:STEVE FURR DATE18.11.01
CORONA,CA 8D9RIVE,#302 REV.# BY DATE DESCRIPTION namast4
HERITAGE LAKE SOLAR
DWG TITLE: PAGE#: SCALE: 888 Federal Boulevard
SITE LOCATION: Denver,CO,80204
INDIVIDUAL 27484 KOBUK VALLEY DRIVE 303.447.0300
PLOT PLAN 3 NTS MENIFEE,CA
NOTES
l�
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
PV AC DISCONNECT
EXTERIOR - GARAGE
UTILITY METER &
MAIN SERVICE PANEL
NEMA 3R JUNCTION BOX (VERIFIED BY BUILDER)
(-I' OUTSIDE ARRAY)
AC COMBINER BOX
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 12.00A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:CHRISTINE MARTINI DATE:18.10.31
CHELSEA AT 980 LENNAR: REVIEWED BY:STEVE FURR DATE:18.11.01
CORONA,
CA198D91VE,#302 SOLAR
HERITAGE LAKE REV.# BY DATE DESCRIPTION
888 Federal Boulevard
DWG TITLE: PAGE #: SCALE:
SITE LOCATION: Denver,CO 80204
INDIVIDUAL 27484 KOBUK VALLEY DRIVE 303.447.0300
PLOT PLAN 4 NTS MENIFEE, CA
PLACARDS