Loading...
PMT18-05560 City of Menifee Permit No.: PMT18-05560 29714 HAUN RD. MENIFEE, CA 92586 Type: Residential Electrical MENIFEE MENIFEE Date Issued: 11/27/2018 PERMIT Site Address: 27496 KOBUK VALLEY DR, MENIFEE, CA Parcel Number: 92585 Construction Cost: $9,691.68 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM, 12 PANELS, 3.660 KW, PLAN 2912 Work: CHELSEA TR 34406-6 LOT 64 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN KIMBERLY CURTIS Applicant Phone: 9493891756 SAMANTHA MAZELLA License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN KIMBERLY CURTIS ALISO VIEJO, CA 92656 Fee Description QQrt Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING &SAFETY_PERMIT/PLAN CHECK APPLICATION., MENI-FEE DATE: 11/19/2018 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER City of M imifee TYPE: COMMERCIAL RESIDENTIAL MULTI FAMILY MOBILE HOME POOL/SPA SlAbilding Dept. SUBTYPE: ADDITION ALTERATION DEMOLITION ELECTRICAL MECHANICAL NEW PLUMBING RE-ROOF NUMBER OF SQUARES NOV Z 201$ DESCRIPTION OF WORK Solar Permit- Chelsea @ Heritage Lake rr% L;1 ed Plan Type: 0(l KW: 3. 6 PCS: Z Master Solar Permit#: PMT — ©-4 PROJECT ADDRESS 27 V qG ZOO"t `daLt,M _%�VAVr / ZIP 92585 ASSESSOR'S PARCEL NUMBER LOT 6�- TRACT 34406-6 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANT NAME Lennar Homes f California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? YES NO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION $ q, SO.FT L SQ FT APPLICANT'S SIGNATURE DATE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL �0 GREEN SMIP a OWNER BUILDER VERIFIED YES NO DRIVERS LICENSE# NOTARIZED LETTER YES NO City of Menifee Building & Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofinenifee.us ENtF r SYSTN INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM QTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.660 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. BOVIET BVM6610M(305W) BUYER: -- — — INVERTER 12 PCS. ENPHASE 107-60-2-US ROOF TYPE CONC.TILE DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD QTY 12 NA NA NA BUYER: __--------_------ ---- TILT 18° NA' NA' NA' DATE: ----------------- - AZIMUTH 104° NA' NA° NA' City of Menifee Building Dept. NOV 2 1 2018 '46 if fcammoft Received r�J rn 'a � O a 0 N PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NEMA 3R JUNCTION BOX CITY OF ENIFEEI 14 (-1' OUTSIDE ARRAY) BUILDING AND SAFETY DEPARTMEN PLAN APPROVAL REVIEWED BY DATE NOTE:DIMENSIONS ARE S owoopowofthwplans shall not be construed to be a permit for,or an �\ approval of,any violation of any provisions of the federal,state or city ,® regulations an�pjormpes. This set of approved plans mustkeEk�gqn Oe ITJobsite untilCoftflolJON 2 LOMARTINI DATE:18.10.31 C H E L S E A AT REVIEWED BY:STEVE FURR DATE:18.11.01 980 ,CA I 92879 REV.# BY DRIVE,#302 DATE DESCRIPTION ncmcsti HERITAGE LAKE CORONNTO AA, SOLAR DWG TITLE: PAGE #: SCALE: SITE LOCATION: 888 Federal Boulevard Denver,CO 80204 INDIVIDUAL 27496 KOBUK VALLEY DRIVE 303.447.0300 PLOT PLAN I 1/16"=1'-0" MENIFEE,CA SYSTEM LAYOUT MODULE SPECIFICATIONS AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL LOCATION MEN.>__,C.. INVERTER MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INVERTER MODEL INVERTER SPEC 107-60-2-US TEMP,AMBIENT LOW(TMIN) ASHRAE EXTREME MIN °C -2 INVERTER MAX POWER(WAC MAX) INVERTER SPEC WATTS(AC) 350 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INVERTER INPUT VOLTAGE Not MAX) INVERTER SPEC VOLTS(OC) 48 TEMP.DETLA LOW(TDELTA) TMIN-TTEST 'C -27 INVERTER OUTPUT VOLTAGE(VAc NOM) INVERTER SPEC VOLTS(AC) 240 MODULE MANUFACTURER MODULE SPEC SOVIET INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MODULE PART NUMBER MODULE SPEC BVM661OM-305 INVERTER OUTPUT CURRENT(IAC) INVERTER SPEC AMPS(AC) 1.00 MODULE POWER STC(P) MODULE SPEC WATTS(DC) 305 INVERTER PHASE QUANTITY INVERTER SPEC PHASE I MODULE OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 32.4 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MODULE OPEN CIRCUT VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 39.9 INVERTER GROUNDING INVERTER SPEC ISOLATED MODULE COEF.VOLT/TEMP(COEFF) MODULE SPEC V/C° -0.124 INVERTER OTY.MAX PER BRANCH CIRCUIT MODULE QTYBc OTY 12 MODULE MAX VOLTAGE(VMAXMOD) (Voc+(TD'COEFF)) VOLTS(DC) 43.25 BRANCH CIRCUIT OUTPUT 0MAX80 (IAC'MODULE OTYBO AMPS(AC) 12.00 MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 9.42 INVERTER OTY.TOTAL MODULE QTYT OTY 12 MODULE SHORT CIRCUIT CURRENT(Isc) MODULE SPEC AMPS(DC) 9.94 TOTAL SYSTEM OUTPUT(IMAXTS) (IAC'MODULE OTYT) AMPS(AC) 12.00 MODULE MAXIMUM CURRENT(IMAX) (Isc-1.25) AMPS(DC) 12.43 MINIMUM AMPACITY REO'D.PER NEC (IMAX'1.25) AMPS(DC) 15.53 SERIES FUSE RATING,MAX MODULE SPEC AMPS(OC) 20 CONDUCTOR SIZING CALCULATIONS CONDUCTOR SCHEDULE 1)CONDITION OF USE(COU): (AMPACITY'TEMP. DERATE'FILL DERATE)vs. REO'D(IMAX) KEY CONDUCTORS CU/AL TYPE LOCATION TRADE 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REO'D,(IMAX' 1.25) A FREE AIR#12 ENPHASE Q CABLE,1-#6G, CU UL3003,DG CABLE ARRAY SOLAR CALC. AMPACITY TEMP. FILL OCD USED B 3-#10-,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR KEY SIZE CU/AL INSULATION TYPE W/O DERATES DERATE DERATE RESULT(A) REOT(A) (A) C 3410,I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR A #12 CU THWN-2 COU 30 0.76 1.00 22.80 12.00 *NEUTRAL CAPPED AND NOT USED TERM 25 25 15.00 20 B #10 CU NM-B Cou 40 0.91 1.00 36.40 12.00 INTERCONNECTION CALCULATIONS TERM 35 35 15.00 20 ITEM UNIT PANEL C #10 CU NM-B COU 40 0.91 LOC 36.40 12.00 PANEL MANUFACTURER CUTLER-HAMMER TERM 35 35 I5.00 20 MINIMUM BUS RATING AMPS 200 ELECTRICAL EQUIPMENT SCHEDULE MAIN DISCONNECT AMPS 200 M��- C AMPS 40 KEY OTY MANUFACTURER MODEL NOTES ETRADE AMPS 20 1 12 SOVIET BVM661OM-305 PV MODULE LOOA x 12(MODS)= 12.00A OF CURRENT 2 12 ENPHASE 107-60-2-US PVINVERTER 12.00A x 1.25= 15.00A 3 1 TBD TBD PV ROOF J-BOX,NEMA 3R,OTY TO VARY TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V 5 1 ENPHASE X-I0-AMI-240-8 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I x 20A-2P.I X 5A-IP SOLAR 7 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 8 1 CUTLER HAMMER TBD PV BREAKER,I X20A-2P,RATING MAY VARY SOLAR 10 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. M 10 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC. II 1 TBD TBD GROUNDING ELECTRODE,LIFER BLDR.ELEC. O 9 4a20A/2 OO 20A/2P N G G G A g C C — II I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.660KIN LOT#64 LENNARORIGINAL BY:CHRISTINE MARTINI DATE:18.10.31 CHELSEA AT 980 MO: REVIEWED BY:STEVE FURR DATE:18.11.01 980 NA,CAI 2 DRIVE,#302 REV.# BY DATE DESCRIPTION namast* HERITAGE LAKE CORONA,CA 92879 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard Denver,CO 80204 INDIVIDUAL 27496 KOBUK VALLEY DRIVE 303.447.0300 PLOT PLAN 2 NTS MENIFEE,CA ELECTRICAL 4 INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. (SEE FIGURE 1) 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)ROOFTOP JUNCTION BOX WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. ALL PENETRATION ASSEMBLIES WILL BE INSTALLED PER MANUFACTURERS' INSTRUCTIONS AND WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE TILE ROOF SURFACE. 6)THE IRONRIDGE XR RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE IRONRIDGE XR CODE-COMPLIANT INSTALLATION MANUAL 7)IRONRIDGE TOP CLAMPS REQUIRE A 0.37 INCH SPACE BETWEEN PV MODULES. IF UFO END CLAMP IS USED,XR LIGHT RAILS MUST EXTEND ONE INCHES V,)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)IRONRIDGE XR REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 100'. ELECTRICAL NOTES: GENERAL 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90oC RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE INVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR 8)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 9)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 10)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 11)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 12)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 13)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122 14)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. SIGNAGE 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J". 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. 21) INTERCONNECTION BREAKER TO BE LOCATED OPPOSITE MAIN BREAKER. LENNAORIGINAL BY:CHRISTINE MARTINI DATEi8.10.31 C H E L S E A AT 980 MO: REVIEWED BY:STEVE FURR DATEi8.11.01 Of)CORONA,CA I9 8D91VE,#302 REV.# BY DATE DESCRIPTION SOLAR 8 HERITAGE LAKE ®® SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard Denver,CO 80204 INDIVIDUAL 27496 KOBUK VALLEY DRIVE 303.447.0300 PLOT PLAN 3 NTS MENIFEE,CA NOTES ti CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. PV AC DISCONNECT EXTERIOR -GARAGE UTILITY METER 8. MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NEMA 3R JUNCTION BOX (-I' OUTSIDE ARRAY) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 12.00A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI DATE:18.10.31 980 MO CHELSEA AT : REVIEWED BY:STEVE FURR DATE:18.11.01 80 NTECITO DRIVE,#302 nCmC38rA HERITAGE LAKE CORONA, CA92879 REV.# BY DATE T DESCRIPTION SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard Denver,CO 80204 INDIVIDUAL 27496 KOBUK VALLEY DRIVE 303.447.0300 PLOT PLAN 4 NITS MENIFEE,CA PLACARDS