Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-05559
City of Menifee Permit No.: PMT18-05559 A& 29714 HAUN RD. Type: Residential Electrical MENIFEE, CA 92586 MENIFEE MENIFEE Date Issued: 11/27/2018 PERMIT Site Address: 27515 KOBUK VALLEY DR, MENIFEE,CA Parcel Number: 92585 Construction Cost: $8,884.04 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM, 11 PANELS, 3.355 KW, PLAN 4 Work: HAMPTON TR 34406-3 LOT 5 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN KIMBERLY CURTIS Applicant Phone: 9493891756 SAMANTHA MAZELLA License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN KIMBERLY CURTIS ALISO VIEJO, CA 92656 Fee Description Qty Amount($) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING &„SAFETY PERMIT/PLAN_CHECK APPLICATION E �;��,.._e!,i�5:� saW_Tv i DATE: 11/19/2018 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER CifY Ot We—nil TYPE: COMMERCIAL ;:; RESIDENTIAL MULTI-FAMILY MOBILE HOME POOL/SPA 8(siMg p t. SUBTYPE: ADDITION ALTERATION DEMOLITION ELECTRICAL MECHANIC,�(JQ V 2 1 20 ' NEW PLUMBING RE-ROOF NUMBER OF SQUARES 1� DESCRIPTION OF WORK Solar Permit- Hampton @ Heritage Lake ■ Plan Type: KW: S5 PCs: Master Solar Permit#: PMT ► - CY$C d PROJECTADDRESS Vaa yA N-%S� ZIP 92585 ASSESSOR'S PARCEL NUMBER LOT TRACT 34406-3 (oCa�-eaf LoIf" OWNER NAME Lennar Homes of California, Inc. 3 q0L# AA ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANT NAME Lennar Homes f California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? YES NO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION $ g{ ��y.0(4 SO.FT L SO.FT APPLICANT'S SIGNATURE DATE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: , ,2 CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL GREEN - SMIP I OWNER BUILDER VERIFIED YES NO DRIVERS LICENSE# NOTARIZED LETTER .: YES NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofinenifee.us 4 0ENII SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.355 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE II PCs. BOVIET BVM6610M (305W) BUYER: INVERTER IIPCS. ENPHASE 107-60-2-US ROOF TYPE CONC. TILE DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY II NA NA NA BUYER: TILT 18° NA° NA' NA* DATE: AZIMUTH 196° NA* NA* NA* City of Menife�L ►3Uilding pep NOV 2 1201 R '�4oved LLJ_ '. NEMA 3R JUNCTION BOX (-I' OUTSIDE ARRAY) a PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER a MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX OF MENIFEE 4 E DING AND SAFETY DEPARTMENT PLAN APPROVAL REVIEWED °Y_t 'all I DATE NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF 'Approval of these plans shall not be construed to be a permit for,or an approval of,any violation of any provisions of the federal,state or city 4 PLAN 4 regulationi-zaadA)r bnanceaicths set of approved plans must be kept on thd�1 ORIENTATION 3 iobslte until comp12tionLOT#5 LENNAR: AL BY:CHRISTINE MARTINI I DATE:18.10.31 HAMPTON AT 980 MONTECITO DRIVE,#302 REVIEWED BY:STEVE FURR HERITAGE LAKE CORONA, CA 92879 REV.# BY DATE I DESCRIPTION name DWG TITLE: °AGE #: SCALE: SITE LOCATION: 8 D nveerrCO80204rd INDIVIDUAL 27515 KOBUK VALLEY DRIVE 303.447.0300 PLOT PLAN 1/16, = r 0` MENIFEE, CA SYSTEM LAYOUT MODULE SPECIFICATIONS AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL LOCATION MENIFEE,CA INVERTER MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INVERTER MODEL INVERTER SPEC 107-60-2-US TEMP,AMBIENT LOW(THIN) ASHRAE EXTREME MIN °C -2 INVERTER MAX POWER(WAc MAX) INVERTER SPEC WATTS(AC) 350 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INVERTER INPUT VOLTAGE(Vac MAX) INVERTER SPEC VOLTS(DC) 48 TEMP.DETLA LOW(TOELTA) THIN-TTEST °C -27 INVERTER OUTPUT VOLTAGE(VAc NOM) INVERTER SPEC VOLTS(AC) 240 MODULE MANUFACTURER MODULE SPEC BOVIET INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MODULE PART NUMBER MODULE SPEC BVM661OM-305 INVERTER OUTPUT CURRENT(IAC) INVERTER SPEC AMPS(AC) 1.00 MODULE POWER STC(P) MODULE SPEC WATTS(DC) 305 INVERTER PHASE QUANTITY INVERTER SPEC PHASE I MODULE OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 32.4 COMPLIANCE INVERTER SPEC UL1741/IEEEI547 MODULE OPEN CIRCUIT VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 39.9 INVERTER GROUNDING INVERTER SPEC ISOLATED MODULE COEF.VOLT/TEMP(COEFF) MODULE SPEC V/C° -0.124 INVERTER OTY.MAX PER BRANCH CIRCUIT MODULE QTYBc OTY 11 MODULE MAX VOLTAGE(VMAXMOD) (Voc+(To*COEFF)) VOLTS(DC) 43.25 BRANCH CIRCUIT OUTPUT 0MAXBQ (IAC*MODULE QTYBc) AMPS(AC) 11.00 MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 9.42 INVERTER OTY.TOTAL MODULE QTYT OTY 11 MODULE SHORT CIRCUIT CURRENT(Isc) MODULE SPEC AMPS(DC) 9.94 TOTAL SYSTEM OUTPUT(IMAXTS) (IAc*MODULE OTYT) AMPS(AC) 11.00 MODULE MAXIMUM CURRENT(IMAX) (Isc-1.25) AMPS(DC) 12.43 MINIMUM AMPACITY REO'D.PER NEC (IMAX*1.25) AMPS(DC) 15.53 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 20 CONDUCTOR SIZING CALCULATIONS CONDUCTOR SCHEDULE 1)CONDITION OF USE(COU): (AMPACITY*TEMP.DERATE*FILL DERATE)vS. REQ'D(IMAX) KEY CONDUCTORS CU/AL TYPE LOCATION TRADE 2)TERMINALS(TERM): AMPACITY AT TERMINALS. v5. REQ'D,(IMAX* 1.25) A FREE AIR ENPHASE 0 CABLE,I-06G, CU UL3003,DG CABLE ARRAY SOLAR KEY SIZE CU/AL INSULATION CALC. AMPACITY - TEMP. FILL RESULT(A) RE0'D(A) OCD USED B 3-#10*,I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR TYPE W/O DERATES DERATE DERATE (A) C 3-#10,1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR A #12 CU THWN-2 COU 30 0.76 1.00 22.80 HAD *NEUTRAL CAPPED AND NOT USED TERM 25 25 13.75 20 B #10 CU NM-B Cou 40 0.91 1.00 36.40 11.00 INTERCONNECTION CALCULATIONS TERM 35 35 13.75 20 ITEM UNIT PANEL C #10 CU NM-B COU 40 0.91 L00 36.40 IL00 PANEL MANUFACTURER CUTLER-HAMMER TERM 35 35 13.75 20 MINIMUM BUS RATING AMPS 200 ELECTRICAL EQUIPMENT SCHEDULE MAIN DISCONNECT AMPS 200 ALLOWED PV PER NEC AMPS 40 KEY OTY MANUFACTURER MODEL NOTES TRADE PV OCPD DEVICE USED AMPS 20 II SOVIET BVM6610M-305 PV MODULE SOLAR LOOA X II(MODS)= ILOOA OF CURRENT 2 11 ENPHASE 107-60-2-US PV INVERTER SOLAR II.00A%1.25= 13.75A 3 1 TBD TBD PV ROOF J-BOX,NEMA 3R,OTY TO VARY SOLAR TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-IG-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 20A-2P,I X 5A-IP SOLAR 7 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 8 1 CUTLER HAMMER TBD PV BREAKER,I X20A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 10 10 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC. M II I TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. I lO O O 4 07 SA/IP 3 OO ® © 20AA12P O 20A/2 � i 4 4 4 4 4 � —G �... I G I G _._IN I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.355KW LOT#5 LENNAR: ORIGINAL BY:CHRISTINE MARTINI DATE:18.10.31 H A M P T O N AT REVIEWED BY:STEVE FURR DATE:18.11.01 980 NA, CAI 2 DRIVE,#302 REV.# BY DATE DESCRIPTION namaSG6 HERITAGE LAKE CORONA, CA 92879 1�p SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard INDIVIDUAL 27515 KOBUK VALLEY DRIVE Denver,3.447. 30204 PLOT PLAN 2 NTS 303.447.0300 ELECTRICAL MENIFEE, CA INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. (SEE FIGURE 1) 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)ROOFTOP JUNCTION BOX WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. ALL PENETRATION ASSEMBLIES WILL BE INSTALLED PER MANUFACTURERS' INSTRUCTIONS AND WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE TILE ROOF SURFACE. 6)THE IRONRIDGE XR RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE IRONRIDGE XR CODE-COMPLIANT INSTALLATION MANUAL 7)IRONRIDGE TOP CLAMPS REQUIRE A 0.37 INCH SPACE BETWEEN PV MODULES. IF UFO END CLAMP IS USED,XR LIGHT RAILS MUST EXTEND ONE INCHES(I")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)IRONRIDGE XR REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 100'. ELECTRICAL NOTES: GENERAL 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE INVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR 8)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 9)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 10)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 11)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 12)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 13)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122 14)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING, OR MANUFACTURER'S RECOMMENDATIONS. SIGNAGE 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 101. BUILDER ELECTRICAL AND SOLAR CONTRACTORS 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. 21) INTERCONNECTION BREAKER TO BE LOCATED OPPOSITE MAIN BREAKER. ORIGINAL BY:CHRISTINE MARTINI DATE� 980 MONTECITO DRIVE,#302 HAMPTON AT : REVIEWED BY:STEVE FURR DATE18.11.01 80 HERITAGE LAKE CORONA,CA 92879 REV.# BY DATE DESCRIPTION nQ�1CS DWG TITLE: PAGE#: SCALE: SITE LOCATION: 888 Federal Boulevard INDIVIDUAL Denver,CO 80204 27515 KOBUK VALLEY DRIVE 303.447.0300 PLOT PLAN 3 NTS NOTES MENIFEE,CA CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BOX (-I' OUTSIDE ARRAY) PV AC DISCONNECT \t::�EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: II.00A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI DATE:18.10.31 980 MO HAMPTON AT : REVIEWED BY:STEVE FURR DATE:18.11.01 80 NTECITO DRIVE,#302 REV.# BY ncmastb HERITAGE LAKE CORONA, CA 92879 DATE DESCRIPTION % SOLAR DWG TITLE: PAGE #: SCALE: 888 Federal Boulevard SITE LOCATION: Denver,CO 80204 INDIVIDUAL 27515 KOBUK VALLEY DRIVE 303.447.0300 PLOT PLAN 4 NTS MENIFEE,CA PLACARDS