Loading...
PMT18-05436 City of Menifee Permit No.: PMT18-05436 Arl AV 29714 HAUN RD. ,F MENIFEE, CA 92586 Type: Residential Addition MENIFEE MENIFEE Date Issued: 11/14/2018 PERMIT Site Address: 23924 SAN JACINTO RD, MENIFEE, CA Parcel Number: 350-093-024 92587 Construction Cost: $1,500.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of CONSTRUCT 1) FREESTANDING BLOCK WALL 3'X 25 L FT FRONT YARD AND 1)AS-BUILT Work: FOOTINGS PER CITY STANDARD RETAINING BLOCK WALL BACK SIDE YARD 3'X 57 L FT CODE CASE CE-18-2213 FOR BACK SIDE YARD ONLY Owner Contractor FRANCISCO NICOLAS 23924 SAN JACINTO RD MENIFEE, CA 92587 Applicant License Number: FRANCISCO NICOLAS 23924 SAN JACINTO RD MENIFEE, CA 92587 Phone: 951-216-9766 Fee Description QQt rr Amount($) Building Permit Issuance 1 27.00 Wall/Fence, standard 2 166.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Building 1 8.30 $203.30 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Perrnit_Ternplate.rpt Page 1 of 1 CITY OF MEN EE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which www.le 'nfo.ca.gov/calaw.html. this permit is issued. L/ Policy# Date zi I have and will maintain worker's compensation insurance,as required by PRPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this number are: application and the information I have provided is correct.I agree to comply with all applicable city and county ordinances and state laws relating to Carrier building construction.I authorize representatives of this city or county to Policy# Expires enter the above identified property for' spection purposes. i (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less ERTY OWNER OR AUTHORIZED AGENT ❑1 certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the worker's compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a mixture containing a hazardous material equal to or greater that the Applicant Date amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ONo UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes 4!�No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes ,�gNo NER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist.I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning Contractor's License Law for the reason(s)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 oyes No Business and Professions Code).Any city or county that requires a permit to _ Date construct,alter,improve,demolish or repair any structure,prior to its �pR PERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING(RRP) License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractor's State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE DATE: C�_ I PERMIT/PLAN CHECK NUMBER GRADING/PLANNING CASE NUMBER/OTHER RELATED CASES TYPE: COMMERCIAL 0,RESIDENTIAL MULTI-FAMILY MOBILE HOME POOL/SPA SIGN SUBTYPE: 4-ADDITION ALTERATION DEMOLITION ELECTRICAL MECHANICAL :` N PLUMBING RE-ROOF NUMBER OF SQUARES (� DESCRIPTION OF WORK 1' S G I �l !� / U C lG IOrl 3 f C)c CA v (4 Ion OCCUPANCY GROUP CONSTRUCTION TYPE SPRINKLERS YES � NO PROJECTADDRESS 0 a( 1 .J�\n,SC\C\y ��`. ZIP Cla �D ' ASSESSOR'S PARCEL NUMBER 4 LOT Q71 TRACT OWNER NAME �r_ \)'jC\S CO \, \C.G\C` ADDRESS ,;H SC\V1 J C�`C`v\�U / ; -- l ��1�J�'`? i \ PHONE 11? CC - `i EMAIL SC �OI �� � �/(,Y I ' CIGt� �Y�VO- C�✓�• APPLICANT NAME ADDRESS 6 C„j J-0 /-1_014, C� �I PHONE EMAIL -�nw CONTRACTOR'S NAME OWNER BUILDER? Or YES NO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ `j ( SQ FT L SQ FT APPLICANT'S SIGNATURE DATE OTYSTAFFUSEONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL �Q 3C� GREEN l SMIP I OWNER BUILDER VERIFIED YES C.) NO DRIVERS LICENSE# NOTARIZED LETTER YES NO City of Menifee Building & Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofinenifee.us ENIF CITY OF MENIFEE CODE ENFORCEMENT DIVISION NIF 29714 Haun Road,Menifee,CA92586 Ph:(951)672-6777 Fax:(951)679-3843 NOTICE OF VIOLATION October9,2018 DIEGO FRANCISCO DIEGO N RE: 23924 SAN JACINTO RD 23924 SANJACINTO AVE APN: 350-093-024 CANYON LAKE,CA92587 Case No: CE-18-2213 Officer: Todd Solomon To Whom It May Concern: An inspection of the above referenced property was conducted on October 4,2018.In an effort to improve and restore the community, the City of Menifee is actively enforcing the Menifee Municipal Codes.According to available records, you are listed as an owner or other interested party regarding this property. This Notice of Violation is submitted to you, requesting your cooperation in correcting the violations below. The following violations were observed during the property inspection, it is necessary to perform the corrective action(s) before the Compliance Date.Another inspection will be conducted on or immediately after the compliance date to verify compliance. Code Section Violation Detail&Corrective Action Needed Compliance Date CBC§ 105.1 Permit(s) Any owner or authorized agentwho intends to construct,enlarge, October24,2018 Required(Unpermitted alter,repair,move,demolish,orchange the occupancy of a building Co ns truc tio n In Pro g re s s) or structure,or to erect,install,enlarge,alter,repair,remove, convert,or replace any electrical,gas,mechanical or plumbing system,the ins tallatio n o f whic h is regulated by this code,or to cause any such work to be done,shall first make application to the building o ffic ial and o b tain the required perm it. -The property owner shall take immediate action to correct the substandard condition.If necessary,the property owner shall obtain permits to rehabilitate the structure(s)and make all necessary corrections.If permits orplans are required,please contact Planning or Building&Safety at(951)672-6777 for information on obtaining building permits and permitting requirements.All required permits must be obtained,inspected and approved by Building &Safety. ***INCLUDING RETAINING WALL*** Failure to correct the violations above may result in fines up to $1,000.00 per violation/per day; criminal prosecution, the issuance of a misdemeanor citation, administrative citations, and/or other legal action including abatement proceedings being taken to ensure compliance with the applicable codes. If the city is forced to proceed with abatement proceedings, the owner(s)of record may incur direct costs plus an administrative fee.Any unpaid fines and/or costs will be placed as alien upon the property or sent to an authorized collection agency. The City would like to avoid taking any further actions and requests your cooperation in this matter. By acting immediately to correct the violation(s) referenced, you will avoid further action by the city.If you have any questions, please contact Todd Solomon at (951) 723-3737. Please provide the case numberCE-18-2213 and the property address. We appreciate your cooperation in this matter. PLOT/SITE PLAN REAR PROPERTY LINE CA Azo -1A City of�%&,-,,iifee OF MENIFEE 118 X BUILDING AND SAF T TMENT • NOV -14 2018 t " PLAN APPROVAL " e v P, REVIEWE B LL Uj)k&I 40 D kTE 'Approval of these plans shall not be onst into be a permit r,or in approval of,any violation of any provi ions of-, fede,al,state r cii t% regulations and ordinances. This set approved 09a must be ept n the jobsite until completion. C., kA FRONT PROPERTY LINE Property Owners Name CL Property Address CnCIA SAM)7c\,CA U pui�4-u cp- 01:)-rP City of Menifee Building&Safety Department 29714 Haun Rd.Menifee,CA 92586 951-677-672-677 wwwcitycfmenifee.us Show all Property Lines SAMPLE PLOT/SITE PLAN Provide location, height and lineal and indicate any slopes footage of all proposed block or wood on the property fences and block retaining walls ———————————————————————————————————— 9 -V I Distance 5'-0" Min. I Pools only, all other I' structures Min. Distance 10'-0" Min I Distance 10'-0" Dimension I. Dist ' a 5'-0" Min _ I lance 5'- Show proposed and/or I " Min nI existing additions and 1 Distance 5'-0" identify use, ie... Room I Addition, Patio Cover, j I. A kI Balcony, etc... Include I, b Show proposed and or location, dimensions and "' existing Detached If d g setbacks i c Accessory 5tructure(s), nd identify use, ie... jGarage, Workshop, Pool I j j or Spa. Include location, jdimensions and setbacks I I I_ ��.-^�—'.,'"'W"""'""'"""'"."[5istance 5 0" A�In._ •. Ir I Distance 5'-0" Min I EXISTING DWELLING I I I. _ I I I I I, I I � I d id Sgit'-i I I I I I � I Q I I � 3 W I I � I � I I I CITY STREET Requirements: • Plans and notes shall be legible.Each plan shall fill a minimum 8 1/2"x 11"sheet of paper.Include homeowners name and property address • Show all property lines and the distances of all structures to the property lines.Show all buildings and/or structures on the property, existing and proposed and the distances between those buildings and/or structures • Three(3)copies of the plot plan are required.Some projects may require approval from the Planning Department prior to permit a issuance.Please contact the Planning Department to verify minimum setbacks requirements. • Show a North Arrow on the Plot/Site Plan • For proposed Gas,Electrical and/or Plumbing improvements,show meter locations,conduit size,and number of wires,breaker and wire sizes,linear square footage and their respective locations for each of the trades. City of Menifee Building&Safety Department 29714 Haun Rd.Menifee, CA 92586 951-677-672-677 wwwcityofinenifee.us OE G TYPE 1 : 6" TOE QN S°0?G G TYPE 2: 6" HEEL GQ�NOR°eoe�� 2 NF S�g�E 1M 2 1�gEE�0El2 1 j5��10��2. IF LEVEL GRADE City QI �Vj(�,JifeE) \\\\� GAP • � III SEE TABLE FOR LEVEL G LEVEL GRADE Fm �C1ildi g Bpt � � SEE TABB LE FOR LEVEL GRADE #4 HORIZ.ATTOP COURSE �,� #4 HORIZ.AT TOP COURSE #4 HORIZONTAL REBAR AT PIN CENTER u #4 HORIZ.AT 24"ON CENTER . Q ;�? 8"CONCRETE BLOCK Y-BARS "H" Y BARS 6-0"MAX Cl M � ,� 6'-0"MAX 2-3/4"MAX.(NOT SHOWN TO SCALE) BU � 2Igj2 f jN CENTER #4 HORIZ.AT 24"ON CENTER 2 ryu Q RTMENT OVAL3"MAX. DRAINAGE SYS. q (12"BLOCK) S (12"BLOCK)' EE NOTE 5 FIN E — 114 INISH GRADE _ RADE _ -- I�I�-1�I� _ _ — __ • [WIlil 16"mi 16G#T X BARS 12► f�ll t t be con rued to be a permit for,o�an . Z-BARS X-B `3'R anY On any provision of the federal,State or city (2)-#4 t' odor i # z-B R$ mca owed plans must be kept on the HORIZONTAL ^K" ti KEBABS l SIK" C� KEBABS 12"� -12" TYPE 1: 6" TOE GRADE "H" "H1" "W" X BARS Y BARS ZBARS "K" CONDITION (WALL HEIGHT) (12" BLOCK) (FOOTING WIDTH) (KEY DEPTH) 5'-1" to 6'-0" 24" 69" #4 @ 16" #4 @ 32" #4 @ 11" 30" SLOPING GRADE 4'-1"to 5'-0" NIR 48" #4 @ 16" 04 @ 16" #4 @ 12" 25" AT TOP OF WALL 3%1"to 4'-0" NIR 30" #4 @ 32" #4 @ 32" #4 @ 32" 116" (2:1 MAX) Up to 3'-0" NIR 18" #4 @ 32" #4 @ 32" #4 @ 32" 8" 5'-1"to 6'-0" 24" 45" #4 @ 24" #4 @ 32" #4 @ 24" 8" LEVEL GRADE 4'-1"to 5'-0" N/R 36" #4 @ 24" #4 @ 24" #4 @ 24" 7" AT TOP OF WALL 3'-1"to 4'-0" N/R 24" #4 @ 32" #4 @ 32" #4 @ 32" 5" Up to 3'-0" NIR 21" #4 @ 32" #4 @ 32" #4 @ 32" N/R TYPE 2: 6" HEEL GRADE "H" "H1" "W" X BARS Y BARS ZBARS "K" CONDITION (WALL HEIGHT) (12" BLOCK) (FOOTING WIDTH) (KEY DEPTH) 5'-1" to 6'-0" 24" 39" #4 @ 16" #4 @ 32" #4 @ 12" 28" SLOPING GRADE 4'-1"to 5'-0" NIR 29" #4 @ 16" #4 @ 16" #4 @ 12" 22" AT TOP OF WALL 3'-1"to 4'-0" NIR 24" #4 @ 32" #4 @ 32" #4 @ 32" 15" (2:1 MAX) Up to 3'-0" NIR 18" #4 @ 32" #4 @ 32" #4 @ 32" 8" 5'-1"to 6'-0" 24" 33" #4 @ 24" #4 @ 32" #4 @ 24" 18" LEVEL GRADE 4'-1"to 5'-0" NIR 26" #4 @ 24" #4 @ 24" #4 @ 24" 13" AT TOP OF WALL 3'-1"to 4'-0" N/R 20" #4 @ 32" #4 @ 32" #4 @ 32" 7" Up to 3'-0" NIR 20" #4 @ 32" #4 @ 32" #4 @ 32" NIR 1 N/R = NOT REQUIRED 'SEE PAGE 2 FOR ADDITIONAL INFORMATION' WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM 1n . CITY OF MENIFEE DISCLAIMER: BUILDING DEPARTMENT ALTERNATE RETAINING WALL DESIGNS MAY ENIFE BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED ANALYSIS. USE OF THIS RETAINING WALLS STANDARD DESIGN IS AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 GUARANTEE AGAINST FAILURE OR DEFECTS. FAx(951)679-3843 2/24/2014 WWW.CITYOFMENIFEE.US PAGE i OF2 GENERAL NOTES: 1)ALL WORK SHALL CONFORM TO THE ADOPTED CODES AND ZONING REGULATIONS. 2)CONCRETE BLOCK MASONRY SHALL COMPLY WITH THE FOLLOWING: A. CONCRETE MASONRY SHALL CONFORM TO ASTM C-90,GRADE-N. B. MORTAR:TYPE M OR S. C. GROUT ALL CELLS W/2000 PSI PORTLAND CEMENT GROUT. 3)THE ULTIMATE COMPRESSIVE STRENGTH REQUIRED FOR FOUNDATION CONCRETE SHALL BE 2500 PSI. 4)ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE ASTM A61 5-40 AND OVERLAP SPLICES SHALL BE 40 BAR DIAMETERS MINIMUM. ALL REBAR HOOKS SHALL BE A MINIMUM OF 1 2 TIMESTHE REBAR DIAMETER(1 2bd)IN LENGTH. 5) PROVIDE RETAINING WALL DRAINAGE SYSTEM AS FOLLOWS: !� :30 PROVIDE 1 CF/FT OF CLEAN COARSE GRAVEL WITH 4" DIAMETER PERFOR ED PVC DR NIAG. PI E WITH 1%GRADIENT TO DRAIN - OR OMIT HEAD JOINTS INF I,�,S T C,O.RSE.,( " 00A t��+���.' 6)OPTIONAL: INSTALLATION OF A MOISTURE BARRIER ON THE FILL SIDE OF THE WALL�kILL'HEEP-TO PREVENT MOISTURE FROM PENETRATING THE VISIBLE SIDE OF THE WALL, RESULTING IN DISCOLORATION. 7)THIS RETAINING WALL STANDARD IS NOT DESIGNED T®SUPPORT SURCHARGE LOADS FROM MOTOR VEHICLES OR OTHER STRUCTURES. 8) CLEANOUTS SHALL BE PROVIDED FOR ALL GROUT POURS OVER 5 FEET IN HEIGHT. WHERE REQUIRED, CLEANOUTS SHALL BE PROVIDED IN THE BOTTOM COURSE AT EVERY VERTICAL BAR AND SHALL Bf SEALED AFTER INSPECTION AND BEFORE GROUTING. to REQUIRED INSPECTIONS: - - ,f••Igb"ow,gb'�` tT 1) FOOTING: EXCAVATION TRENCH CLEAN WITH STEEL IN PLACE AND SUPPQ_ RTED 3.'--ABOVE AND-AWAY FROM THE SURROUNDING EARTH/DIRT. 2) REBAR/PRE-GROUT AND DRAINAGE SYSTEM, BOND BEAM REBAR AND VERTICAL REBAR IN PLACE-INSPECTION PRIOR TO PLACING GROUT. DRAINAGE SYSTEM COMPLETE. 3) FINAL: AFTER GROUT IS PLACED AND BACKFILL COMPLETED-PRIOR TO ANY DECORATIVE CAP PLACEMENT. SETBACK FROM TOP OF SLOPE: DESIGN PARAMETERS: ALL FOOTINGS ADJACENT TO SLOPES TO BE AT ACTIVE SOIL PRESSURE(PSF) LEAST 5'TO DAYLIGHT AS SHOWN BELOW. LEVEL BACKFILL = 30 IIII=_ SLOPING(2:1 MAX) =43 PASSIVE SOIL BEARING(PSF) =1 50 W COEFFICIENT OF FRICTION =0.25 . a [Ul n ALLOWABLE SOIL BEARING PRESSURE(PSF) =1 500 U=[W=[ : /2:1 MAX. SLOPE (NO INCREASES TAKEN FOR DEPTH OR WIDTH OF FOOTING) •:• III=IIIItIIII= rO � cti BOTTOM OF FOOTING WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM CITY OF MENIFEE A DISCLAIMER: BUILDING DEPARTMENT ALTERNATE RETAINING WALL DESIGNS MAY ENIF BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED ANALYSIS. USE OF THIS RETAINING WALLS STANDARD DESIGN IS AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED GUARANTEE AGAINST FAILURE OR DEFECTS. (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 z FAX(951)679-3843 2/24/2014 1 WWW.CITYOFMENIFEE.US I PAGE 2OF2 FOOTING OPTION "A" FOOTING OPTION 66E399 .4 #4 HORIZONTAL REBAR [A "1771ree (USE BOND BEAM BLOCK) r 1,anpt. T J, 20IR 61, OR 8" BLOCK "H" • "H" HEIGHT FROM TOP Q #4 HORIZONTAL AT 32" MAX. O.C. HEIGHT FROM TOP OF FOOTING (USE BOND BEAM BLOCK) OF FOOTING SEE TABLE"A" SEE TABLE"B" FOR REBAR SIZE FOR REBAR SIZE AND SPACING AND SPACING (LOCATE REBAR IN CENTER OF CELL) (LOCATE REBAR IN CENTER OF CELL) FINISH GRADE #4 REBAR CONTINUOUS 12 10. (2) AR 01. 12' = CONTINUOUS j F11I #4 REBAR REV&RS9 =7 DI F ECVJT HO( 'K (FOOT FOOTING WIDTH)( 01 1EAUQI� DEPARTMENT SEE TABLE"B" PLAN APPROVAL ALL FOOTINGS ADJ CENT TOsr ' TABLE 'j;.. qtOPES TO BE AT L AST 5'TO TABLE "B" AS SHOW'4 BELOW. "H" VERTICAL REINFORCEMENT 3' 17" #4 E 3' 19" #4 @ 48" O.C. 4' 20" #4 @ 48" O.C. 4' 22" #4 9 48"O.C. 5T f 29" #4 @ 48" O.C. C. 5' A XA '4-P n deCe A&Z d istrued to beEWd3W f 62MO;- 4-0. . ".F 5 MIN. 1 6' 1 34" #4 @ 24" O.C. ' @� VVI5.IkI OFFIVY421 V1,ally VIVIduvil ul ally yl M of the fed TM regulations and ordinances. This set of approved plans must be kept on the I RTO§4e until completion. CHECK WITH THE BUILDING DEPARTMENT TO I 1)T VERIFY IF A BUILDING PERMIT IS REQUIRED. fqIS DESIGM DOE-,N15Y Puff-t-1. .......—-PP MORE THAN 6"ON OPPOSING SIDES OF THE WALL. THIS IS WHEN A PERMIT IS REQUIRED,THE FOLLOWING NOT A RETAINING WALL. INSPECTIONS ARE REQUIRED: 2)FENCE HEIGHTS ARE REGULATED-CONSULT ZONING 1)FOOTING;EXCAVATION TRENCH CLEAN WITH REGULATIONS BEFORE BEGINNING CONSTRUCTION. STEEL IN PLACE AND SUPPORTED 311 ABOVE AND 3)NO WATER COURSE OR NATURAL DRAINAGE SHALL BE AWAY FROM THE SURROUNDING EARTH/DIRT. OBSTRUCTED. 2)REBAR/PRE-GROUT*,BOND BEAM REBAR AND 4)GROUT ONLY THE CELLS CONTAINING REBAR. THIS WALL VERTICAL REBAR IN PLACE-INSPECTION PRIOR TO IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. PLACING GROUT. 5)ALL REBAR TO BE ASTM SPEC.A615,GRADE 40 MINIMUM. 3)FINAL;AFTER GROUT IS PLACED-PRIOR TO ANY 6)ALL REBAR LAP SPLICES TO BE 2411 MINIMUM. DECORATIVE CAP PLACEMENT. 7)ALL MASONRY UNITS TO BE ASTM C-90 GRADE N. E3)REBAR TO BE CENTERED IN MASONRY CELLS. WESTERN RivERsIDF COUNTY CODE UNIFORMITY PROGRAM *SEE PAGE 2 FOR ADDITIONAL INFORMATION* CITY OF MENIFEE DISCLAIMER: ENIF BUILDING DEPARTMENT some ALTERNATE DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED FREESTANDING BLOCK WALL ANALYSIS. USE OF THIS STANDARD DESIGN IS AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED GUARANTEE AGAINST (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 FAILURE OR DEFECTS. FAx(951)679-3843 2/24/2014 1 WWW.CITYOFMENIFEE.US I PAGE 1 JOF2CC�40�' REBAR PLACEMENT ILLUSTRATION FOOTING OPTION B 10 (TYPICAL) ALL REBAR SPLICES 24" MIN. OVERLAP ew (TYPICAL) ONLY CELLS AND BOND BEAM COURSES WITH REBAR TO BE GROUTED (DO NOT SOLID GROUT ENTIRE WALL-USE t GROUT STOP MESH AS APPROPRIATE)' FOOTING OPTION A (TYPICAL) ALL REBAR SHALL HAVE A i MINIMUM OF 3" CONCRETE COVER AT FOOTINGS DESIGN PARAMETERS. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM ACTIVE SOIL PRESSURE(PSF) =30 CITY OF MENIFEE PASSIVE SOIL BEARING(PSF) =1 50 BUILDING DEPARTMENT COEFFICIENT OF FRICTION =0.25 NIF ALLOWABLE SOIL BEARING(PSF) =1 500 �. WIND=80 MPH,EXPOSURE C FREESTANDING BLOCK WALL SEISMIC: +" � NA=1.3,Nv=1.6,Z=0.4,SOIL PROFILE=SD (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 # FAx(951)679-3843 2/24/2014 1 WWW.CITYOFMENIFEE.US 1 PAGE20F2