Loading...
PMT18-05138 City of Menifee Permit No.: PMT18-05138 A& 29714 HAUN RD. Type: Residential Re-Roof MENIFEE, CA 92586 MENIFEE MENIFEE Date Issued: 10/25/2018 PERMIT Site Address: 26275 ST MARYS ST, MENIFEE, CA Parcel Number: 337-033-003 92586 Construction Cost: $11,500.00 Existing Use: Proposed Use: Description of REMOVE ALL EXISTING ROOFING LAYERS, INSTALL NEW COOL ROOF SHINGLES Work: **CRRC 0890-0013** Owner Contractor ALBERT DREW SCOT'S ROOFING 26275 ST MARYS STREET 1991 JUNIPERO#C MENIFEE, CA 92586 SIGNAL HILL, CA 90806 Applicant Phone: 5629867661 SCOT CHAMBERLAIN License Number: 708960 SCOT'S ROOFING 1991 JUNIPERO#C SIGNAL HILL, CA 90806 Fee Description Qty Amount($) Building Permit Issuance 1 27.00 Inspections not specified 98 98.00 GREEN FEE 1 1.00 General Plan Maintenance Fee-Building 1 4.90 $130.90 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class C _ �G/ License No. 70 '55 G U + By my signature below I acknowledge that,except for my personal residence Expires b/3•�/ �J Signature in which I must have resided for at least one year prior to completion of T improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which www.leginfo.ca.gov/calaw.html. this permit is issued. Policy# Date have and will maintain worker's compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this number are: application and the information I have provided is correct.I agree to comply with all applicable city and county ordinances and state laws relating to Carrier 5 - T n building construction.I authorize representatives of this city or county to Policy# G7 `1 2 S — c6" Expires �� / enter the above identified property for inspection purposes. — F— (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a mixture containing a hazardous material equal to or greater that the Applicant G Date iU 2 / amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes e No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes "o I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes 6Ao OWNER BUILDER DECLARATIONS 1 have read the Hazardous Material Information Guide and the SCAQMD permitting checklist.I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning Contractor's License Law for the reason(s)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 Business and Professions Code).Any city or county that requires a permit to ❑Yes _;Q No�_ Date / > Z construct,alter,improve,demolish or repair any structure,prior to its PROPERTY NER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING[RRP) License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractor's State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION r• MENIFEE DATE: iU 2 PERMIT/PLAN CHECK NUMBER GRADING/ PLANNING CASE NUMBER/OTHER RELATED CASES TYPE: 0:>COMMERCIAL RESIDENTIAL C-- MULTI-FAMILY MOBILE HOME C POOL/SPA SIGN SUBTYPE: ADDITION ALTERATION DEMOLITION C ELECTRICAL MECHANICAL NEW C PLUMBING RE-ROOF NUMBER OF SQUARES D 5C7 5 DESCRIPTION OF WORK r) 3c, OCCUPANCY GROUP CONSTRUCTION TYPE SPRINKLERS ()YES NO PROJECT ADDRESS 2& 2-7 A�j /,14,Z .t 5 19C4 c C= ZIP % 2 ~-a,+- ASSESSOR'S PARCEL NUMBER 33-1- OD�F) LOT TRACT OWNER NAME Aor3C-rL - E) Cit y Of Menifee _ Building Dept. ADDRESS 2 co 'Z-t 7S- S a PCLIc C PHONE EMAIL APPLICANT NAME SG o i3ea-n&q/ ADDRESS 1p`! J41ev(Pc),7 U L L c)-7S� PHONE SV Z 7-2 -7 y EMAIL SC o %CCU 2CD CONTRACTOR'S NAME SCv S 2oU F, / L OWNER BUILDER? YES NO BUSINESS NAME ADDRESS E 5 6-'V-9 L 4,/c- C Uf- c,7 PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER 7yy5; LICENSE CLASSIFICATION VALUATION$ // 5 U C SQ FT L SQ FT T APPLICANT'S SIGNATURE DATE �U z OTYSTAFFUSEONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: f CITY OF MENIFEEEBBUSINES LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE II,6 o'g&%c INVOICE TOTAL , .�0 GREEN l SMIP OWNER BUILDER VERIFIED YES NO DRIVERS LICENSE# NOTARIZED LETTER YES NO City of Menifee Building & Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 GV-ry oa www.cityofinenifee.us `'�MENIFEI �4 r .0, STATE OF CALIFORNIA RESMDENTIAL ALTERATIONS - REROOFING • CEC-CFj1R-ALT-01-E(Revised 06114) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CFIR-ALT-01-E REROOFING Prescriptive Residential Alterations for Reroofing in Climate Zone 10 City Of 2) j ul mg Uept. A.GENERAL INFORMATION Site address: -7 Mg2y`S P(/-1Ge-- Existing roofing type: p��,. �-- 5 G/Z 5 New roofing type: City,Zip Code: MENIFEE, CA Total roof area(sgft): Building Type: `s_Single Family Dwelling ❑ Multi Family Dwellings Total reroof area(sgft): Climate Zone:• 10 %reroof area: C.ROOF REPLACEMENT(COOL ROOF)* 11 2 3 4 5 6 7 8 9 10 11 12 13 Method of Roof CRRC Product R-value Proposed Minimum Required Co �pliance Pitch Exception Product ID Type Deck Initial Aged Thermal SRI Aged Thermal SRI >2:12 number Insulation Solar Solar Emittance (Optional) Solar Emittance (Optional) Reflectance Reflectance Reflectance .aoD. 0.20 ao 3X 0.20 0.75 16 NOTES • Roo area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. •Liquid field applied coatings must comply with installation criteria from section 110.8(i)4. *ROO�-REPLACEMENT(Prescriptive Alteration,Section 150.2(b)1H) When bO%or more of the roof is being replaced the roofing requirements are triggered.Any areas of roof covered by building integrated photovoltaic panels and solar thermal panels(the area of roof)not covered by photovoltaic panels would still need to meet any applicable cool roof requirements).Additionally,there are many alternatives/exceptions when a cool roof is required. When the roof is steep slope(pitch>2:12)the roof requirements include a cool roof in climate zones 10-15.The minimum requirement is 0.20 aged solar reflectance,0.75 thermal emittance, or a m mmum SRI of 3.6.When the roof is low slope(pitch 5 2:12)cool roof is NOT required in climate zone 10. Instructions for sections with column numbers are given below: 1. Method of Compliance:indicate if the method of compliance is going to be based on Aged Solar Reflectance and Thermal Emittance,the Solar Reflectance Index(SRI),or an Exception. 2. Roof Pitch:Expressed as 4:12,for example,which means the roof rises 4 foot within a span of 12 feet.When roofs have multiple pitches the requirements are based on the pitch of 50%or more of the roof. 3. Exception:If meeting one of the exceptions.Indicate which exception is,or will be,met. EXCEPTIONS AND ALTERNATIVES FOR STEEP SLOPE ROOFS: a) Mass roof 25 Ibs/ft2 or greater(uncommon situation such as sod roof); b) Air space 1"from top of roof deck to bottom of roofing; c) Roofing product has a profile ratio of rise to width of 1 to 5 for 50 percent or greater of the width of the roofing product; d) Ducts shall either be in directly conditioned space as confirmed by field verification and diagnostic testing in accordance with Reference Residential Appendix RA3.1.4.3.8 or be insulated to a minimum installed level as specified by TABLE 150.1-A.All ducts shall meet all applicable mandatory requirements of Section 150.0(m).In the City of Menifee,R-6 is required. CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E RERCICIFING��j Prescriptive Residential Alterations for Reroofing in Climate Zone 10 (page 2 of 21 e) Roof has R-38 insulation; f) Roof has a radiant barrier; g) No ducts are installed in the attic;or h) R-4 insulation above-the roof deck. NOTE:If one of the exceptions above has been selected than the rest of section C is Not Required. 4. The CRRC Product ID Number is obtained from the Cool Roof Rating Council's Rated Product Directory at www.cooIroofs.org/products/results.Products are listed by manufacturer, brand,type of installation,roofing material,and color,as well as product performance. 5. Product type:See Cool Roof Rating Council's directory.Generally product types'include single-ply roof,wood shingles,asphalt roof,metal roof,and tile roof. 6. R-value Deck Insulation:If one of the exceptions selected includes adding roof deck insulation,indicate the R-value of insulation. 7. Proposed Initial Solar reflectance:base on the product chosen from the Cool Roof Rating Council's Rated Product Directory.If using default assumption indicate NA since the Aged solar reflectance is available. 8. Proposed Aged Solar Reflectance:Value is from the Cool Roof Rating Council's Rated Product Directory.If the aged value is not available,calculate the calculated Aged Solar reflectance using the Solar Reflectance Index(SRI)Calculation worksheet located on the California Energy Commission website or the aging equation Pag,A0.2+01131 itiar0.2],where pi„itiai=the initial solar reflectance and soiling resistance a is listed by product type below. V/GLUES OF SOILING RESISTANCE R BY PRODUCT TYPE Product Type CRRC Product Category R Field-Applied Coating Field-Applied Coating 0.65 Other Not A Field-Applied Coating 0.70 9. Proposed Thermal Emittance:From the product specification default value.If using a calculated SRI place the thermal emittance used to calculate SRI. 10. Proposed SRI:It is optional to meet either the SRI but if chosen to do so,use the Solar Reflectance Index(SRI)Calculation Worksheet found on the California Energy Commission website http://www.energy.ca.gov/title24/. 11. Minimum Required Aged Solar Reflectance:Based on climate zone and roof slope. 12. Minimum Required Thermal Emittance:Based on climate zone and roof slope. 13. Minimum SRI:Based on climate zone and roof slope. NOTE:If the cool roofing requirements will be met by a liquid field applied coating,Section 110.8(i)4 requires the coating be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the manufacture r. DOCUMENTATION AUTHOR'S DECLARATION STATEMENT •I certify that this Certificate of Compliance documentation is accurate and complete. Name: S C v i C /Fi`1r3 L,-7 CA<. ..6 Owner o Authorized agent o Contractor Signature: Company: 5 C o 7 j /Lou '', Contractor license#: '7 p 4g,4� G U Address: /'J <-I nJ/PL/1 d C/ v 7 S. Phone: S(_p Z _ 5 72 f4s 7 City/State/Zip: S/Gig,q C y i C_ �. U�S Date: For assistance or questions regarding the Energy Standard::,contact the Er* t 1_j&_ no.�!�