Loading...
PMT18-04871 City of Menifee Permit No.: PMT18-04871 29714 HAUN RD. MENIFEE, CA 92586 Type: Residential Electrical MENIFEE MENIFEE Date Issued: 10/29/2018 PERMIT Site Address: 24760 PARADISE MEADOWS DR, Parcel Number: MENIFEE, CA 92584 Construction Cost: $16,000.00 Existing Use: Proposed Use: Description of SOLAR TR 32025 THE RIDGE Work: 12 MODULES, 12 MICROINVERTERS,4.02kW LOT 173 Owner Contractor KB HOME COASTAL, INC SUNPOWER CORPORATION SYSTEMS 36310 INLAND VALLEY DR 414 HARBOUR WAY S STE 1901 WILDOMAR, CA 92595 RICHMOND,CA 94804 Applicant Phone: 9417203850 MASON LITVINOFF License Number: 890895 SUNPOWER CORPORATION SYSTEMS 414 HARBOUR WAY S STE 1901 RICHMOND, CA 94804 Fee Description Qty Amount($) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 3.00 General Plan Maintenance Fee- Electrical 1 12.60 $295.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Tem plate.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION `M f Menifee DATE 10/04/2018 PERMIT/PLAN CHECK NUMBER �:J 4 01 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION ❑✓ ELECTRICAL ❑MECHANICAL []NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Roof Mounted PV 4.02 kW 12 Modules With Micro Inverters PROJECT ADDRESS 24760 PARADISE MEADOWS DRIVE ASSESSOR'S PARCEL NUMBER LOT 173 TRACT PROPERTY OWNER'S NAME RICHMOND AMERICAN HOMES ADDRESS 5171 CALIFORNIA AVE. SUITE 120 IRVINE, CA 92617 PHONE EMAIL APPLICANT NAME Mason Litvinoff ADDRESS 1979 E. Guasti Road, Suite B, Ontario, CA 91711 PHONE (408)218-6811 EMAIL Mason.Litvinoff@sunpowercorp.com CONTRACTOR'S NAME Neil DeLucenay OWNER BUILDER? ❑YES ✓❑NO BUSINESS NAME SunPower Corporation, Systems ADDRESS 1414 Harbour Way South, Suite 1901, Richmond, CA 94804 PHONE (951)581-5483 EMAIL tyler.santangelo@sunpowercorp.com CONTRACTOR'S STATE LIC NUMBER 890895 LICENSE CLASSIFICATION B, C10, C46,A VALUATION$ $ 16,000.00 SQ FT L SO.FT APPLICANT'S SIGNATURE DATE DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN , r SMIP INVOICE c SAID AMOUNT AMOUNT J � %CASH CHECK# CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT CASH CHECK# CREDIT CARD VISA/MC OWNER BUILDER VERIFIED OYES NO DL NUMBER NOTARIZED LETTER YES NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 NOTES:ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. ARE T WIDE FIRE ACCESS PATH DIMENSIONS OF THE INSET ARE LARGER THAN THE ARRAY AND SHALL BE CONFIRMED BY THE BUILDER BEFORE THE INSTALLATION. 1 ' CITY OF MENIF E BUILDING ANDSAFE PLAN APPROV k1L REVIEWED r-------------- --------------- I` C7 C] I� C7 C] C, C, C3 C, 'Approval of these plans sl iall t be approval of,any violation c f an prov CONCRETE o 0 o TILE ROOF regulations and ordinances Thi set jobsite until completion. 4:12 TRANSITION BOX C7 O C7 C3 I� .C7 C7 I I O ' I i ' I I i SERVICE POINT AND C7 UTILITY METERING • ROOF ACCESS POINT " f f „ y DRMAY TO ELECTRICmot ' UTILITY GRID s7 C] C] C] 12 MODULES SPR-X21-335-BLK-D-AC 14'-1 " 21 ' ON RACK (S-TILE) INVISCMOUNT City of Menitee Building Dept. Received' PLAN S696 (PALMER) (SCHEME 1) ELEVATION A (4.02 kVi) PLAN ELEVATION DOCUMENT TITLE S U N P O W E R 5696(PALMER A THE RIDGE AT AUDIE ROOF S-TILE' 1110 RP-5T 4 INDIVIDUAL SYSTEM S-TILE RP-54648 PLOT PLAN MURPHY RANCH FRONT ARRAY CORPORATION, SYSTEMS ARRAY LAYOUT SYsiEx o0.1fxTAnon SYSTEM SIZE 1414 HARBOUR WAY SOUTH 2450 4.02 kW DRAWN BY REVISION R I C H M O N D, CA 9 4 8 0 4 CUSTOMER SITE LOCATION STORY HOME TYPE ROOF PITCH MANDAYA O 2-STORY 4:12 DATE(5 1 0) 5 4 0-0 5 5 0 RICHMOND AMERICAN HOMES 24760 PARADISE MEADOWS DRIVE ARRAY Sq FT. LOT NO. 5171 CALIFORNIA AVE.SUITE 120 MENIFEE,CALIFORNIA 92584 215 S�.FT. 09-17-2018 SHEET IRVINE,CA 92617 PHASE scnLE i ew "TMsnos e"e, ron,TWQio :�.COm�Kouun an�unox 11 1 1/16"—v-0" 1 ■ CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED F 0 THE FOLLOWING SOURCES WITH DISC C' r city P"iXcla o,oran LOCATED AS SHOWN: oved plans must be kept on he ir C3 o�=I c C3 ,( c o 0 0 0 0 0 o PHOTOVOLTAIC oT T r T �T ARRAY ON ROOF I I I I I I I I I I I I I I I I I I I I I I I I I I 0 a DRIVEWAY o c o MAIN SERVICE PANEL 24760 PARADISE MEADOWS DRIVE SIGNAGE NOTES 1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE,WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. 2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITHIN MINIMUM 3/8"LETTER HEIGHT,WHITE ON RED BACKGROUND. 3.DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. I �I P PIN ELEVATION DOCUMENT TITLE S V 1 \ 1 W E R 5696(PALMER A THE RIDGE AT AUDIE ROOF STILEE INDIVIDUAL MURPHY RANCH SYSTEM FRONT PLOT PLAN CORPORATION, SYSTEMS PV DIRECTORY PLAQUE o RIENTA70N SYSTEM SIZE 1414 HARBOUR WAY SOUTH 246° 4.02 kW PRAWN By REVISION CUSTOMER SITE LOCATION STORY HOME TYPE ROOF PITCH 0 RICH MON D, CA 9a804 2-STORY 4:12 MANDAYA (s 1 0) 5 a 0-0 5 5 0 RICHMOND AMERICAN HOMES 24760 PARADISE MEADOWS DRIVE DATE ARRAY IQ FT. LOT NO. 09-17-2018 SHEET 5171 CALIFORNIA AVE.SUITE 120 MENIFEE,CALIFORNIA 92584 215 SQ.FT. 1 ReaROaJa�Ox",�o�s°cw'u�a`n°"'sE"i."No°ur"�vEc�Fi` x00�"�»oAiu.ioN IRVINE,CA 92617 PHASE scnLE 11 CUSTOM 2