PMT18-04261 City of Menifee Permit No.: PMT18-04261
29714 HAUN RD.
MENIFEE, CA 92586 Type: Residential Electrical
MENIFEE MENIFEE Date Issued: 0813012018
PERMIT
Site Address: 29937 WINTER HAWK RD, MENIFEE, CA Parcel Number: 338-351-014
92586 Construction Cost: $400.00
Existing Use: Proposed Use:
Description of INSTALL NEW 60A EV CHARGING STATION IN GARAGE
Work:
Owner Contractor
MICHAEL TARVER RHODES ELECTRIC INC
29937 WINTER HAWK ROAD 29668 AVENIDA DE SERENO
MENIFEE, CA 92586 MENIFEE,CA 92586
Applicant Phone:9517752132
DILLON RHODES License Number: 1020135
RHODES ELECTRIC INC
29668 AVENIDA DE SERENO
MENIFEE,CA 92586
Fee Description City Amount($1
Services, Switchboards,Control Centers&Panels 1 116.00
Building Permit Issuance 1 27.00
Additional Plan Review Building 129 129.07
GREEN FEE 1 1.00
General Plan Maintenance Fee-Electrical 1 5.80
$278.87
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
CITY OF MENIFEE Y'..1
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
with a licensed contractor(s)pursuant to the Contractors State License Law).
I hereby affirm under penalty of perjury that 1 am under provisions of
Chapter9(commencing with section 70D0)of Division 3 of the Business and o I am exempt from Ilcensure under the Contractor's State License Law for
Professions Code and my license is in full force and effect. the following reason:
License Class L O - Ucen a D'[o 13 By my signature below I acknowledge that,except for my personal residence
Expires 2 2 Signature in which l must have resided for at least one year prior to completion of
WORKER'S COMPENSATION DECLARATION improvements covered by this permit I annDt legally sell a structure that I
have built as an owner-builder If it has not been constructed in its entirety by
• o l hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which swny ie info. ovc aw.html.
this permit is issued.
Policyp AGENTDate
have and will maintain worker's compensation insurance,as required by RPERTY OWNE AUTHORI OR OR
section 370D of the Labor Code.for the performance of the work for which o By my signature below l certify to each of the following:I am the property
this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this
number are: application and the Information I have provided is correct.I agree to comply
Carrier !Sr _ FUn.3 t with all applicable city and county ordinances and stale laws relating to
..Zoe tr - building construction.l authorize representatives of this city or county to
Policy �227 SS 7— Expires _ O enter the"dentifred property for inspection purposes.
(This section need not to be completed is the permit Is for one-hundred �Z Dater
dollars($100)or less P OPERTY OWNER OR AUTHORIZED AGENT
D I certify that in the performance of the work for which this permit is issued,
I shall not emolov any persons in any manner so as to become subject to the CITY BUSINESS LICENSE 0
worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the worker's compensation provisions of Section 3700 of the Labor
Code,I shall fotthwifh mply with those provisions. Will the applicant or future building occupant handle hazardous material or
mixture containing a hazardous material equal to or greater that the
Applicant Date ( D amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVE RA E15 oyes . No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,0001,IN occupant require a permit for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist
IN SECTION 370E OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguidelines
CONSTRUCTION LENDING AGENCY DYes Ili-No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is issued outer boundary of a school?
(Section 3097 Civil Code) o Yes ){NO
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm under penalty of perjury that 1 am exempt from the permitting checklist.I understand my requirements under the State of
Contractor's License Law for the reason(s)indicated below by the
California Health&Safety Code,Section 25505 and 25534 concerning
hazardous material reporting.
checkmark(s)I have plated nett to the applicable item(s)(Section 7031.5
Business and Professions Code).Any city or county that requires a permit to
_�./�� Dale
construcissuance,alsoalter,improve, appldemolish or repair any itrto Me a signets to p ' OWNER OR AUTHORIZED AGENT
issuance,also requires the applicant for the permit to Poe a signed statement
that he or she is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING fRRPI
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she Is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply With
an Applicant fora permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500). managers who do the paint-disturbing work themselves or through their
D1,as owner of the property,or my employee with wages as their sale employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is svww.eoa.eov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-BDO-424-LEAD(5323).
Code;The Contractor's State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not Intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. D No EPA Lead-Safe Certified Firm is required for this project because:
a 1,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7D44,Business and Professions
Code:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION I MENIFEE
DATE: L ( PERMIT/PLAN CHECK NUMBER - Q
GRADING/PLANNING CASE NUMBER/OTHER RELATED CASES
�( � o Menifee
0 TYPE: Q COMMERCIAL 6-RESIDENTIAL O MULTI-FAMILY ® MOBILE HOME O POOL/SP t
SUBTYPE: ()ADDITION ()ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL ONEW ()PLUMBING ORE-ROOF NUMBER OF SQUARES AUG J_ 8 2018
DESCRIPTION OF WORK C-4
OCCUPANCY GROUP y, CONSTRUCTION TYPE SPRINKLERS®YES ()NO
PROJECT ADDRESS 2 q 9/ -7 ZIP Z
ASSESSOR'S PARCEL NUMBER - �- al.� LOT TRACT
OWNER NAME 17 I C (
ADDRESS (�,, �� �q7 /� ,U �`7✓�-u,L�
PHONE �1"1 i2 y �-J 7 EMAIL
APPLICANT NAME {,
ADDRESS Z
PHONE EMAIL
CONTRACTOR'S NAME E NERBUILDER7 ®YESC)NO
BUSINESS NAME
ADDRESS
PHONE 9�� 7/�7 f Z EMAIL \
CONTRACTOR'S STATE LIC NUMBER �O Zo I nj LICENSE CLASSIFICATION C--)
VALUATION$ SO FT L So.FT
APPLICANT'sSIGNATURE DATE 2 r
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION ACCEPTEDBY: � CITY OF MENIFEE BUSINESSUCENSENUMBER
BUILDING PLANNING ENGINEERING FIRE PXJ
INVOICETOTAL 1 GREEN 1 _ SMIP
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE N NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586(951)672-6777
www.cityofm en ifee.us
SHIGLE FAMILY EXISTING DWELLING
City of Menifee
ELECTRICAL SERVICE CALCULATIONS Building Dept.
D1(a)One-Family Dwelling AUG 2 B 2018
29937 Winter Hawk Road
1. GENERAL LIGHTING LOADS Received
Dwelling 3334 Sq. Ft x 3 VA (220.12) = 10002 VA
Small appliance loads (220.52) 1,500 VA x 2 circuits = 3000 VA
Laundry load (220.52)(B) 1,500 VA x 1 circuits = 1500 VA ^�
General Lighting Loads Total: 14502 VA CMMMa
3000 VA x 100% 3000 VA L
Remaining Load x 35% 4026 VA
Net Load: ?026 VA Lim,
U MENIFEE
2. COOKING EQUIPMENT LOADS (22 55)' iNV AND SAFETY DEPARTMENT
Oven GAS VA y;q APPRQ1/AL 1
Oven 0 VA i
-4-4 , j 9
Cooking Equipmerf'Loaota�YAV
G/X 0 2018 `
3. ELECTRIC DRYER (220.54), Namelflate, 5,000 VA min.
DATE
"'
Dryer(s) Gas VA j - se plans shall not be construed tobeapermit for,oran
v1014011 of any provisions of the federal,state or city
Dryer load total: ruinances. This set of approved plans%&Oe kept on the
np1enon.
4. FIXED APPLIANCE LOADS (220.53)--- f
Compactor 0 VA Disposal 780 VA
Dishwasher 660 VA Wine Cooler 288 VA !�
Microwave 1200 VA Other 0 VA
Fixed appliance load total: 2928 VA
5. MOTOR LOAD(S) (220.18) (pool pumps 0 VA
6. EV charging station 11520 VA
7. HEATING OR AC LOAD (220.82) (B) 8160 VA
8. NET CALCULATED LOAD: 44136 VA
9. COMPUTED LOAD = optional loads total/240 volts: 184 AMPS
10. MINIMUM SIZE SERVICE REQUIRED: 200 AMPS
29937 Winter Hawk Rd
Single Lune
(1) 3/4" CONDUIT
(3) 10' # 6 THHN
(1) 10 # 10 THHN GROUND GREEN
(1) 2 pole 60 amp breaker
MAIN PANEL Te
200 AMP rCslj
on60
ALL WORK MUST COMPLY WITH THE
2016 CALIFORNIA BUILDING,
ELECTRICAL, MECHANICAL, PLUMBING,
GREEN, AND ENERGY CODES.
v �
c
180
0
h j
r,
h AM
Mims
1 ALL WORK MUST COAT WITH THE
2016 CALIFORNIA BUILDING,
ELECTRICAL, MECHANICAL, PLUMBING,
GREEN, AND ENERGY CODES.
WALL COWWECTOR
The Wall Connector is a Tests specific charging station, hard wired and permanently mounted to a wall or
post..Redesigned in Spring 2016,highlights include:
• Compatible with Model S and Model X
• Customizable power settings to fit any electrical system
• Power sharing:Link up to four Wall Connectors to a single circuit
• Two cable length options:8.5'or 24'
• Indoor and outdoor rated
Flave a licensed electrician review the electrical load of your home prior to installation. As with any home
improvement project,a permit and city inspection may be required.
RECHARGE RATES FOR STANDARD AND HIGH AMPERAGE CHARGING
_ SO-arnps
-ianuarci (48A draw) JO.
,;nAmperage 90-amps 52 46'
(72A draw)
'Numbers based on a90D configuration and 240-volt power supply Recharge speeds may vary.Refer to the Wall Connector
installation guide for additional power level options.
RECOMMENDED LOCATIONS ADDITIONAL RESOURCES
EMAIL
CHARGINGIhISTALLATIOiNtaTESLA.COM
PHONE
24/7 TECH SUPPORT
E;1 11-16,3 7 52
y= WEB
TESLA.CONI/SUPPORT
_ ONLINE STORE
CHARGE PORT SHORTESL .COM
RECOMMENDED LOCATION FOR 24'CABLE
' RECOMMENDED LOCATION FOR 8.5'CABLE
T=S L(, 45500 Fremont Boulevard, Fremont,CA 945381 May,20161 Version 3