Loading...
PMT18-04221 City of Menifee Permit No.: PMT18-04221 ` ti' 29714 HAUN RD. Type: Residential Electrical Ay � MENIFEE,CA 92586 MENIFEE MENIFEE Date Issued: 0 812 812 01 8 PERMIT Site Address: 25467 KAMRAN CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM,9 PANELS,9 MICROINVERTERS,2.880 KW Work: OAK HILL II TR 37102 LOT 10 Owner Contractor JCA HOMES SUNSTREET ENERGY GROUP LLC 26040 ACERO 760 NORTHWEST 107 AVENUE MISSION VIEJO, CA 92691 MIAMI, FL 33172 Applicant Phone: 3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description Py. Amount($l Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pernil_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE 08/23/2018 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL 0 RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION ❑✓ ELECTRICAL ❑MECHA �j{of Menifee ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES Ulfding Dept. DESCRIPTION OF WORK INSTALL 2.88OkW ROOF MOUNTED PV SYSTEM AUG 2 7 2018 PROJECT ADDRESS 25467 KAM RAN CIRCLE,MENIFEE,CA 92586 ASSESSOR'S PARCEL NUMBER LOT 10 TRACT 37102 PROPERTY OWNER'S NAME JCA HOMES ADDRESS 26040 ACERO,MISSION VIEJO,CA 92691 PHONE (949)614-1434 EMAIL AMANDA.KASHANI@JCAHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES©NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $7,626.00 SO FT L SO FT APPLICANT'S SIGNATURE' DATE 08/23/2018 r DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN ' SMIP INVOICE 'A .� pgID AMOUNT AMOUNT O OCASH O CHECK# OCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0 CHECK If 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES 0 NO DL NUMBER NOTARIZED LETTER O YES 0 NO City of Menifee Building& Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 0TY I MFR. I MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.880 KW I I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS.1 LG I LG320NIK-A5(320) BUYER: INVERTER 9 PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE CONC. TILE DATE: -- SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 9 NA NA NA BUYER' ------+-�-y�-- TILT 1 23° 1 NA' I NA' I NA° GATE: ■ AZIMUTH I92° NA° NA• NA* City of Menifee r Building Dept. '�av AUG 2 7 2018 10'-I'ARRAY Received ; - 10'-11,FLASHING 21' CITY OF I 1EN 16 BUILDIN AN SOLADECK ANS ITIO WIRE TRANSITION BOX PLAN AP IRC (UNDER ARRAY) REVIEW B 'Approval of h se pla PV AC DISCONNECT approval Of,an *Ial EXTERIOR-GARAGE regulations and rdim UTILITY METER 8 jobsite until Coi 1PId MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX (EXTERIOR-GARAGE) i IIIII Iulll • NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN I ELEVATION D-LEFT ORIENTATION I LOT#10 OAK HILLS JCA HOMES ORIGINAL BY:DUSTIN LANNING DATE:17.07.12 REVIEWED BY:JIM PARKS I DATE:17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION •� MISSION VIEJO,CA 92691 d namaste SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 1 4571 Broadway Street INDIVIDUAL 25467 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN I I/16'=1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY I QTY I MANUFACTURER MODEL NOTES TRADE 1 9 LG LG320NIK-A5(32OW) PV MODULE SOLAR 2 9 ENPHASE 106PLUS-72-ACM-US PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER,I X 20A-2P. I X 5A-IP SOLAR B I CUTLER-HAMMER TBD PV BREAKER, I X 2OA-ZP,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL.200A BUS BLDR. ELEC. 10 1 TBD TBD UTILITY METER,IPH,120/24UV.200A BLDR. EIEG. 11 1 TBD I TBD GROUNDING ELECTRODE.UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM I UNIT IPANEL LOCATION MENIFEE,CA PANEL MFR. I CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 1200 TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT I AMPS 1 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC I AMPS 1 40 TEMP,DELTA LOW(T)ELTA) TMIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD, MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD.PART NUMBER AC MODULE SPEC L6320NIK-A5(32OW) I.DAX R(MODS)-10.534 OF c0BREW MOD.POWER STC(P) AC MODULE SPEC WATTS(DC) 320 10.53A A 1.25=13.16 A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED MEANER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC I VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I 'EE COMPLIANCE AC MODULE SPEC UL1741 /IEEE1547 GROUNDING AC MODULE SPEC ISOLATED I SAF DE MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 9 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. QTY Bc OTY 9 AL BRANCH CIRCUIT OUTPUT.IMAXBC (IAC°MOD.QTY K) AMPS(AC) 10.53 AC MODULE QUANTITY.TOTAL MOD.OTY T OTY 9 TOTAL SYSTEM OUTPUT IMAXTS (IAC°MOD.QTY T) AMPS(AC) 1 10.53 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY-TEMP.DERATE°FILL DERATE)vs.REQ'D(IMA%) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REO'D,(IMAX• 1.25) HEY SIZE CU/AL INSULATION C' AMPACITY W/O TEMP. FILL M(A) USEDCA) 'D OCD TYPE DERATES DERATE DERATE USED(A)A #12 CU THWN-2 COU 30 0.76 1.0 3TERM 25 16 20 ^all not be D stNe B #10 CU NM-B COU 40 0.91 I.0 3of any provisins of TERM 35 16 20C #10 CU NM-B COU 40 0.91 1.0 3 2s. This set of ppmv TERM 35 16 20 CONDUCTOR SCHEDULE _ KEY 1 CONDUCTORS I CU/AL I TYPE 1 LOCATION 1 TRADE A I I-#12 ENGAGE CABLE,146G.FREE AIR I CU I TC-ER I ARRAY SOLAR O 6 3-#10.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10,1-#10 EGC I Cu I NM-B(ROM") I INTERIOR I SOLAR vi 5 O4 SA IP OO O 20A/2P O •■ 20A/2P nN G G G ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.880KW LOT#10 ORIGINAL BY:DUSTIN LANNING I DATE:17.67.12 OAK HILLS JCA HOMES REVIEWED BY:JIM PARKS DATE:17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION it MISSION VIEJO.CA 92691 tsnamaste SOLAR DWG TITLE: 72NCT'S LE: SITE LOCATION: 4571 Broadway SDeel INDIVIDUAL 25467 KAMRAN CIRCLE EmIder.CO 80304 PLOT PLAN MENIFEE,CA 303.447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48.O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, APRIL 2016 EDITION 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES IT)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. IU BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES:GENERAL- �L pT 0 ALL PV EQUIPMENT WILL BE TESTED Aim LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 'AR I EN1 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703. IEC61646,IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. be a p rmitf01 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING.CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE federal Stale O ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. plans nl ist be k 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. - 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REOUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. JCA HOMES ORIGINAL BY:DUSTIN LANNING DATEi7.07.12 OAK HILLS REVIEWED BY:JIM PARKS I DATE17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION MISSION VIEJO, CA 92691 •to namasG6 SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 BmacWay Street INDIVIDUAL 25467 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE.CA 303.447.03DO NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE--,-_, UTILITY METER& MAIN SERVICE PANEL .ATE (VERIFIED BY BUILDER) AC COMBINER BOX -an (EXTERIOR-GARAGE) Ir h� on the SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877—SLR—POWR PV POWER SOURCE — AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 10.53A I PC..NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DUSTIN LANNING DATE17.07.12 JCA HOMES OAK HILLS REVIEWED BY:JIM PARKS I DATEi7.07.13 26040 ACERO REV.# BY DATE DESCRIPTION MISSION VIEJO. CA 92691 _ d f1OM=16 i0LA4 DWG TITLE: PAGE*: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 25467 KAMRAN CIRCLE Boulder,CO W304 PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300 PLACARDS