Loading...
PMT18-04219 City of Menifee Permit No.: PMT18-04219 < 29714 HAUN RD. Type: Residential Electrical ./ MENIFEE,CA 92586 MENIFEE MENIFEE Date Issued: 08/28/2018 PERMIT Site Address: 25450 KAMRAN CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,474.00 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM, 10 PANELS, 10 MICROINVERTERS,3.200 KW Work: OAK HILL II TR 37102 LOT 8 Owner Contractor JCA HOMES SUNSTREET ENERGY GROUP LLC 26040 ACERO 760 NORTHWEST 107 AVENUE MISSION VIEJO,CA 92691 MIAMI, FL 33172 Applicant phone: 3054854110 KRISTEN MURRAY License Number. 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee.Description 0y. Amount f$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pernit Template.rpt Page 1 of 1 ROME 1b,k1`-1 Nieni Tee DATE 08/23/2018 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN SUBTYPE: ❑ADDITION ❑ALTERATION []DEMOLITION ❑✓ ELECTRICAL [-]MECHANICAL CIA/ IC feE: ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK INSTALL 3.200kW ROOF MOUNTED PV SYSTEM AUG 2 PROJECT ADDRESS 25450 KAMRAN CIRCLE, MENIFEE,CA 92586 ASSESSOR'S PARCEL NUMBER LOT 8 TRACT 102 PROPERTY OWNER'S NAME JCA HOMES ADDRESS 26040 ACERO,MISSION VIEJO, CA 92691 PHONE (949)614-1434 EMAIL AMANDA.KASHANI@JCAHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $8,474.00 c� SQ FT L SQ.FT APPLICANT'S SIGNATURE 0 812 3/2 01 8 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN ,� SMIP INVOICE PAIDAMOUNT AMOUNT OCASH OCHECKp OCREDIT CARD VISA/MC PLANCHECKFEES PAIDAMOUNT OCASH OCHECKW OCREDITCARD VISA/MC OWNER BUILDERVERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO City of Menifee Building& Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY I MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.200 XW I I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS.1 LG I LG520NIK-AS(320) BUYER: _ INVERTER 10 PCSl ENPHASE I I06PLUS-72-ACM-US ROOF TYPE CONIC. TILE DATE: SUB-ARRAY INFORMATION T ARRAY#I ARRAY#2 ARRAY#3MNAc MOD CITY 10 NA NA BUYER: TILT 23' NA° NA' NA' DATE: AZIMUTH 120' NA. NA. City of Menifee Building Dept. ,cmm') AUG 2 7 2018 16'-9-ARRAY Receiver 1T-T FLASHING '-2' DI DI CITY 0 ME I I BUILD G PLAN PPI REVIE EC SOLADECK WIRE TRANSITION BOX fthes (UNDER ARRAY) *Approval approval f,any regulation and c PV AC DISCONNECT job5ite tl fil Con EXTERIOR-GARAGE { UTILITY METER 8 MAIN SERVICE PANEL '-' (VERIFIED BY BUILDER) AC COMBINER BOX (EXTERIOR-GARAGE) I NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2 ELEVATION C-RIGHT ORIENTATION I LOT#8 ORIGINAL BY:DUSTIN LANNING I DATE;I7.D7.12 OAK HILLS JCA HOMES REVIEWED BY:JIM PARKS I DATE:17.07.I3 26040 ACERO REV.# BY DATE DESCRIPTION •� MISSION VIEJO, CA 92691 Qb namasr6 vouv DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmdway Sveel INDIVIDUAL 25450 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN I I/I6'=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 10 LG LG320NIK-A5(320W) PV MOD(ILE SOLAR 2 10 1 ENPHASE 106PLUS-72-ACM-US PV INVERTER SOLAR 3 1 RSTC ISO 0786-3R5. PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 IENPHASE IQ ENVOY ENV-IOAMI-240 PV DATA MONITOR.I20V SOLAR 6 I IENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 7 I 1 ENPHASE TBD PV BREAKER, I X 20A-2P.I X 5A-IP SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER, IX 20A-2P,RATING MAY VARY SOLAR 9 I TBD TBD SERVILE PANEL,ZOOA BUS I BLDR. ELEC. 10 1 1 TBD TBD UTILITY METER.]PH. 1201240V,200A BLUR. ELEC. III I TBD I TBD GROUNDING ELECTRODE,UFER BLDR. ELM- AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAx) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS Z00 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP.DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CAL CS: MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(320W) 1.17A x IXM0D5)=11J0A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(I%) 320 IIJOA x 1.25=14.43 A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/F 2 SPACE FV BACKEgIpaR MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 ,�D SAFETY T�I D�E NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT UAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEL HZ(AC) 60/59.3-60.5 OVAL OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL174,1 / IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 10Alf AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY Bc QTY 10 3Y BRANCH CIRCUIT OUTPUT.IHAXBC (IAC•MOD.OTY ac) AMPS(AC) 11.70 AC MODULE QUANTITY,TOTAL MOD.OTY T QTY 10 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD.OTY T) AMPS(AC) IL70 CONDUCTOR SIZING CALCULATIONS lans shall not hec StMel U CONDITION OF USE(COLD: (AMPACITY• TEMP. DERATE• FILL DEBATE)m REO'D(IHAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS. REO'D.(IHAx• 1.25) 3tion of any provisi ns of KEY I SIZE I CU/AL INSULATION I CALL' AMPACITY W/0 TEMP. FILL RESULT REQ'D OCDantes, This setof rov TYPE DERATES DERATE DERATE (A) (A) USED(A) pP A 1 #12 1 CU THWN-2 COU 30 0.76 1.0 22.80 11.70 ;Ion, TERM 25 25 14.63 20 B 1 #10 CU NM-B COU 40 0.91 I.0 36.40 11.70 TERM 35 35 14.b3 20 C #10 CU NM-8 COU 40 0.91 1.0 36.40 IL70 TERM 35 1 35 1 14.0 1 20 CONDUCTOR SCHEDULE T222F KEY CONDUCTORS CU/AL TYPE LOCATION TRADE CABLE. 1-#6G.FREE AIR CU TC-ER ARRAY SOLAR g 3-#10.1-#10 EGC CUNM-B(ROMEX) INTERIOR SOLARC 3-#10,I-#W EGC CU NM-B(ROMEX) INTERIOR SOLAR55A/IPOIO O ZOAl2 �N r G G G A B C C — II ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.20o KW LOT#8 ORIGINAL BY:DUST OAK HILLS N CANNING DATE:17.07.12 JCA HOMES REVIEWED BY:JIM PARKS I DATE:17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION MISSION VIEJO, CA 92691 ';5*namaste -- xorAx DWG TITLE: PAGE#: SCALE: SITE LOCATION: 461 Broadway Street INDIVIDUAL 25450 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN 2 NITS MENIFEE.CA 303.447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, APRIL 2016 EDITION 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(<')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. IU BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. zTMEN ELECTRICAL NOTES: 1 GENERAL- ALL \ U PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 1�{ Ila 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC DAl WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. I)e a permit I 3r,or ar 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. 'ederal,state or(:lty SOLAR CONTRACTOR- .lans must be kept on 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703,IEC61646,IEC6I730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT}. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY I0'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- I9)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DUSTIN LANNING DATE17.O7. JCA HOMES I2 OAK HILLS REVIEWED BY:JIM PARKS DATE17.07.13 26040 ACERO REV.#__ BY GATE DESCRIPTION MISSION VIEJO,CA 92691 d namasbER _ eoua DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broa"ay Street INDIVIDUAL 25450 KAMRAN CIRCLE BONBer,GO 80304 PLOT PLAN 3 NTS MENIFEE.CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. _-- 6T___—M7 DI n1 of al -I NI I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX (EXTERIOR-GARAGE) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC.,NEC 69e.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DUSTIN LANNING I DATE17.07.12 JCA HOMES OAK HILLS REVIEWED BV:JIM PARKS I DATE17.07.15 26040 ACERO REV.B BY DATE DESCRIPTION •� MISSION VIEJO,CA 92691 _ �amasud SOLAR DWG TITLE: PAGE n: I SCALE: SITE LOCATION: 4571 Broedwey Street INDIVIDUAL 25450 KAMRAN CIRCLE Boulder.GO 80304 PLOT PLAN 4 NITS MENIFEE,CA 303.447.0300 PLACARDS