Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-04218
City of Menifee Permit No.: PMT18-04218 29714 HAUN RD, Type: Residential Electrical MENIFEE,CA 92586 MENIFEE MENIFEE Date Issued: 0 812 812 01 8 PERMIT Site Address: 25462 KAMRAN CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost $8.474.00 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM, 10 PANELS, 10 MICROINVERTERS,3.200 KW Work: OAK HILL II TR 37102 LOT 7 Owner Contractor JCA HOMES SUNSTREET ENERGY GROUP LLC 26040 ACERO 760 NORTHWEST 107 AVENUE MISSION VIEJO,CA 92691 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI,CA 33172 Fee Description gty Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION ` Meng ee DATE 08/23/2018 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: [—]ADDITION ❑ALTERATION ❑DEMOLITION [Z]ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES City of Menifee �Ull�ll.g Dept. DESCRIPTION OF WORK INSTALL 3200kW ROOF MOUNTED PV SYSTEM _ AUG 2 2018 PROJECT ADDRESS 25462 KAMRAN CIRCLE, MEN IFEE,CA 92586 Received ASSESSOR'S PARCEL NUMBER. LOT 7 TRACT 37102 PROPERTY OWNER'S NAME JCAHOMES ADDRESS 26040 ACERO,MISSION VIEJO,CA 92691 PHONE (949)614-1434 EMAIL AMANDA.KASHANI@JCAHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑✓NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $8,474.00 SO FT L SQ FT �n' DATE 0 8/2 312 01 8 APPLICANT'S SIGNATURE -- CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN — SMIP p� INVOICE PAID AMOUNT AMOUNT 0CASH 0CHECK# 0CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.2GO KW I I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS.I LG I LG320NIK-A5(320) BUYER: INVERTER 10 PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 10 NA NA NA BUYER: TILT 23• I NA' I NA' INA' DATE: City Of Menlfea AZIMUTH 1 162° 1 NA' I NA- Building pt. AUG 2 7 2018 Received 16'-9-ARRAY 1T-7-FLASHING 3' D CITY OF ENI' BUILDIN AN' PLAN AP RO' SOLADECK WIRE REVIEWS 9 TRANSITION BOX MMNI (UNDER ARRAY) in 'Approval of the a plat approval of,any Violat regulations and Irdina 1obsite until coi ipleti( PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) u COMBINER BOX (E 4,x (EXTERIOR-GARAGE) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF IV PLAN p ELEVATION D-RIGHT ORIENTATION 1 LOT#7 ORIGINAL BY:DUSTIN LANNING I DATE:17.07.12 OAK HILLS JCA HOMES REVIEWED BY:JIM PARKS I DATE:17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION •_� - MISSION VIEJO,CA 92691 01 DL 18.08.21 PLAN CHANGE �b namaste SOLAR DWG TITLE: PAGE #: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 25462 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN I/I6'=I'-0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 10 LG LG320NIK-A5(32OW) PV MODULE SOLAR 2 10 ENPHASE 106PLUS-72-ACM-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-SR5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR' 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V,30A SOLAR 5 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,ROY SOLAR 6 1 ENPHASE X-I0-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER.I X 20A-ZP.I X 5A-IP SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER, I X ZOA-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL.200A BUS BLDR. ELEC. 10 1 TBD TBD UTILITY METER.IPH,1201240V,200A BLDR.ELEC. II I TBD TBD GROUNDING ELECTRODE.UFER I BLUR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM I UNIT I PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(THAX) ASHRAE 2% °C 37 BUS RATING AMPS 1200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT I AMPS IZOO TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC I AMPS 1 40 TEMP,DELTA LOW(TEELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED I AMPS I 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC LG320NIK-AS(32OW) L17A s IO(MODS)=030A OF CURRENT MOD.POWER STC(P) AC MODULE SPEC WATTS CDC) 320 11.70A x 1.25=14.63 A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE Pv BACKFEEO B -— MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC I VOLTS(AC) 240/211-264 cE NOMINAL OUTPUT CURRENT OAC) AC MODULE SPEC AMPS(AC) 1.17 � r NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.5-60.5 I SAFETY 1/ DEI OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE COMPLIANCE AC MODULE SPEC UL1741 / IEEEI547 q GROUNDING AC MODULE SPEC ISOLATED AL MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 10 AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD. OTY BC QTY 10 BRANCH CIRCUIT OUTPUT,IMAXBC (IAC'MOD.QTY BC) AMPS(AC) 11.70 AC MODULE QUANTITY,TOTAL MOD.QTY T OTY 1 10 TOTAL SYSTEM OUTPUT IMAXTS (IAC-MOD. QTY T) AMPS(AC) 11.70 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY°TEMP.DERATE ' FILL DERATE)vs.RiE 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REDID.(IMAx°1.25 :hall not be cot sWed KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT TYPE DERATES DERATE DERATE (A) ;fan r0Vi51 s of t A #12 CU THWN-2 COU 30 0.76 1.0 22.80 y p TERM 25 25 3. This set of a prove B #10 CU NM-B COU 40 0.91 1.0 36.40 TERM 35 35 C #10 CU NM-B COU 40 0.91 I.0 36.40 TERM 35 35 14.63 120 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE 10 p -#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR O B 3-#10,1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 13410.1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O 5 O4 SA/IP ©. O O O 20AIff O 20A/2P �N ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.20OKW LOT#7 ORIGINAL BY:DUSTIN LANNING I DATE:17.07.12 OAK HILLS JCA HOMES REVIEWED BY:JIM PARKS I DATE:17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION MISSION VIEJO,CA 92691 01 DL 18.08.21 PLAN CHANGE 0 namasbe souv DWG TITLE: nPAGE#- CALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 25462 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN ITS MENIFEE,CA 303.447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(;')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 0')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: RTI AEN1 GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 1 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730. •9B d erditio 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS, edef r state c 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE any n USt be M ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- I5)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J% 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER, 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. JCA HOMES ORIGINAL BY:DUSTIN LANNING DATEf7.07.12 OAK HILLS REVIEWED BY:JIM PARKS 1 DATE17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION MISSION VIEJO,CA 92691 01 OIL 18.08.21 PLAN CHANGE o namastd SOLAR OWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 25462 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. n 0 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT I� EXTERIOR-GARAGE krE UNLITY METER A MAIN SERVICE PANEL I an (VERIFIED BY BUILDER) AC ty COMBINER BOX (E (E%TERIOR-GARAGE) on the SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE — AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC..NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION JCA HOMES ORIGINAL BY:DUSTIN LANNING DATE17.07.12 OAK HILLS REVIEWED BY:JIM PARKS I DATE17.07.13 26040 ACERO REV.# BY DATE I DESCRIPTION MISSION VIEJO,CA 92691 01 DL I8.08.21 PLAN CHANGE tit SOILe auv DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 25462 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS