Loading...
PMT18-04217 City of Menifee Permit No.: PMT18-04217 29714 HAUN RD. Type: Residential Electrical MENIFEE, CA 92586 MENIFEE MENIFEE Date Issued: 0 812 812 01 8 PERMIT Site Address: 25474 KAMRAN CIR, MENIFEE,CA Parcel Number: 92584 Construction Cost: $8,474.00 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM, 10 PANELS, 10 MICROINVERTERS,3.200 KW Work: OAK HILL II TR 37102 LOT 6 Owner Contractor JCA HOMES SUNSTREET ENERGY GROUP LLC 26040 ACERO 760 NORTHWEST 107 AVENUE MISSION VIEJO, CA 92691 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description Q�t Amount I$) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pernit_Template.rpt Page 1 of 1 & SAFETY PERMIT/PLAN CHECK APPLICATION 10 Menifee DATE 08/23/2018 PERMIT/PLAN CHECK NUMBER - Q TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILE HOME POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION []DEMOLITION ❑✓ ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK INSTALL 3.200kW ROOF MOUNTED PV SYSTEM QtY of Menifee AUG Z PROJECTADDRESS 25474 KAMRAN CIRCLE, MEN IFEE, CA92586 018 ASSESSOR'S PARCEL NUMBER LOT 6 TRACT PROPERTY OWNER'S NAME JCA HOMES ADDRESS 26040 ACERO, MISSION VIEJO,CA 92691 PHONE (949)614-1434 EMAIL AMANDA.KASHANI@JCAHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? [:]YES ✓❑NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $8,474.00 SO FT L SO FT APPLICANT'S SIGNATURE " DATE 08/23/2018 ONLY DEPARTMENT DISTRIBUTION ^ CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN ,' SMIP p INVOICE ����]] PAIDAMOUNT / ,y.� AMOUNT 0�1 •{J[v 9CASH CCHECK# OCREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT OCASH 0CHECK# 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER C YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.200 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS. LG I L6320NIK-A5(320) BUYER: INVERTER IO PCS.1 ENPHASE I I06PLUS-72-ACM-US ROOF TYPE CONC. TILE DATE: �. SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3MNA' MOD OTY IO NA NA BUYER: �- TILT 23' NA' NA' m AZIMUTH I80° NA- NA' DATE: City of Menifee C' Building Dept. AUG 2 7 2018 �T--- Receiv >1 > CITY OF ME BUILDING A PLAN AlPR SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) REVIEWED 'Approval of It iese p approval of,a iy viol regulations ar J ordil jobsite until mmple PV AC DISCONNECT '- — EXTERIOR-GARAGE UTILITY METER 8 b MAIN SERVICE PANEL (VERIFIED BY BUILDER) (E COMBINER BOX i (EXTERIOR-GARAGE) (A•\`7 Ib'-9'ARRAY I7'-T FLASHING b' O NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 2 ELEVATION A-RIGHT ORIENTATION I LOT#6 ORIGINAL BY:D(STIN LANNING DATE:17.07.12 OAK HILLS JCA HOMES REVIEWED BY:JIM PARKS I DATE:I7.07.I3 26040 ACERO REV.# BY DATE DESCRIPTION MISSION VIEJO, CA 92691 Qe namasGIli, SOLAR DWG TITLE: PAGE #: SCALE: SITE LOCATION: 4571 Broadway Steel INDIVIDUAL 25474 KAMRAN CIRCLE Boulder,CO 80304 PLOT PLAN I I/I6' = I'-0' MENIFEE,CA' 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 10 LG L6320NIK-A5(320W) PV MODULE SOLAR 2 10 ENPHASE 106PLUS-72-ACM-US PVINVERTER SOLAR 3 I RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NE14A 3R SOLAR 4 I CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 I ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER.I X 20A-2P, I X 5A-IP SOLAR B I CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 10 1 TBD 1 TBD UTILITY METER, IPH,120/240V.200A BLDR.ELEC. 11 1 TBD TBD GROUNDING ELECTRODE.UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM I UNIT 1PANEL LOCATION MENIFEE,CA PANEL MFR. 1 CUTLER-HAMMER TEMP,AMBIENT HIGH(TIMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT I AMPS 1 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC I AMPS 1 40 TEMP,DELTA LOW(TOELTA) TMIN-TTEST °C -27 PV OCPD DEVICE USED I AMPS 1 20 -- MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC LG320NIK-A5(320W) LI]A x IG(MOGG)=IL70A OF CNRRENT .FEE MOD.POWER STC(P) AC MODULE SPEC WATTS(m) 320 IL7oA x Iz5=m.63 A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-v+WITH A 2BAaP 2 SPACE PV BACXFEED DE MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 Y!lA NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 /IEEE1547 GROUNDING AC MODULE SPEC ISOLATED 1( MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 10 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC OTY 10 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC•M00.0TY BC) AMPS(AC) II.70 AC MOLE QUANTITY, TOTAL MOD. QTY T OTY 10 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD.OTY T) AMPS(AC) 11.70 ;shall not be D nstru CONDUCTOR SIZING CALCULATIONS not any provis ons0 U CONDITION OF USE(COU): (AMPACITY•TEMP. DERATE •FILL DERATE)vs.REO'D(IMAX) 2)TERMINALS.(TERM): AMPACITY AT TERMINALS.VS. REQ'D.(IMAX• 1.25) 'zs. This set o appro KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. I FILL RESULT I REO'D OCD ) TYPE DERATES DERATE IEEBATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 0.76 11.0 122.80 111.70 1 TERM 25 25 14.63 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 11.70 TERM 35 1 1 35 114.63 1 20 C #10 1 CU I NM-B COU 40 0.91 11.0 1 36.40 11.70 TERM 35 35 14.63 20 CONDUCTOR SCHEDULE o KEY CONDUCTORS CU/AL TYPE LOCATION TRADE O A 1-#12 ENGAGE CABLE.I-#6G,FREE AIR CU TC-ER ARRAY SOLAR M B 3-#10. -#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 1 3-#10. 1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 9 5 44 5A/IP O O 0 0 0 20A/2 3 20A/2 �N G G G A B C L = II ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.200KW LOT#6 ORIGINAL BY:DUSTIN LANNING I DATE:17.07.12 JCA HOMES OAK HILLS REVIEWED BY:JIM PARKS I DATE:17.07.13 26040 ACERO REV.# BY DATE DESCRIPTION •, MISSION VIEJO.CA 92691 namaste LOUR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway.CO8 304 PLOT PLAN 2 NTS 25474 E,C AN CIRCLE BO303.44 080004 ELECTRICAL MENIFEE,CA 303.447.030D INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(})SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER.THAN 40'. 9)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. IU BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ART MEN ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH, PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. O be d I ermitfl 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. '-tedef I,state 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. .plans r iust t)e SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AID SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. IL)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT}'. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DUSTIN LANNING DATEI7. JCA HOMES 07.12 OAK HILLS REVIEWED BY:JIM PARKS DATE17.07.13 26040 ACERO MISSION VIEJO,CA 92691 REV.# BY DATE DESCRIPTION 2namaste 01AR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: Street INDIVIDUAL 4571 Broadway 3N PLOT PLAN 3 NTS 28474 KAMRAN CIRCLE Boulder,CO B000 NOTES MENIFEE,CA 303.407.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. r O - - --&I DI DI of of I I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) ATE or an city on the PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX (EXTERIOR-GARAGE) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A 1 PC..NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DUSTIN LANNING DATE17.07.12 JCA HOMES OAK HILLS REVIEWED BY:JIM PARKS DATH7.07.13 MISSIERO N VIEJ REV.# BY DATE DESCRIPTION MISSION VIEJO,CA 92891 namasCAR SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Brwdwey Slreel INDIVIDUAL 25474 KAMRAN CIRCLE Bouldw,CO 00304 PLOT PLAN 4 NTS MENIFEE.CA 303.447.030D PLACARDS