PMT18-04024 City of Menifee Permit No.: PMT18-04024
29714 HAUN RD.
MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE MENIFEE Date Issued: 08/30/2018
PERMIT
Site Address: 30621 SAGE CREEK DR, MENIFEE, CA Parcel Number: 358-660-019
92584 Construction Cost: $6,779.00
Existing Use: Proposed Use:
Description of ROOF MOUNTED SOLAR SYSTEM,8 PANELS,8 MICROINVERTERS,2.560 KW
Work: DAKOTA TR 32025
LOT 19
Owner Contractor
WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC
11870 PIERCE STREET,STE 100 760 NORTHWEST 107 AVENUE
RIVERSIDE, CA 92505 MIAMI, FL 33172
Applicant Phone:3054854110
KRISTEN MURRAY License Number: 1001133
SUNSTREET ENERGY GROUP LLC
760 NORTHWEST 107AVENUE
MIAMI, CA33172
Fee Description gyt Amount(EI
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pennit_Template.rpt Page 1 of 1
- ivienifee oLAC)Q
LA
DATE 08/08/2018 PERMIT/PLAN CHECK NUMBER PffTY-02985
TYPE: ❑COMMERCIAL Q RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION ❑✓ ELECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING [I RE-ROOF-NUMBER OF SQUARES Cit Ot
DESCRIPTION OF WORK INSTALL 2.560kW ROOF MOUNTED PV SYSTEM Building Dept.
AUG 14 2018
PROJECT ADDRESS 30621 SAGE CREEK DRIVE, MEN IFEE, CA 92584
ASSESSOR'S PARCEL NUMBER 368-660-019 LOT 19 TRACT 32025
PROPERTY OWNER'S NAME WOODSIDE HOMES
ADDRESS 11870 PIERCE STREET SUITE 250
PHONE (951)710-1912 EMAIL RICKJ@WOODSIDEHOMES.COM
APPLICANT NAME KRISTEN MURRAY
ADDRESS 6531 IRVINE CENTER DR SUITE 200
PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM
CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LEG OWNER BUILDER? ❑YES❑✓NO
BUSINESS NAME SUNSTREET ENERGY GROUP LLC
ADDRESS 6531 IRVINE CENTER DR SUITE 200
PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM
CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B
VALUATION$ $6,779.00 SO L FFT� L SO FT
APPLICANT'S SIGNATURE T'4't' IL Y 1 DATE 08/08I2018
DEPARTMENT DISTRIBUTION CITY DF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING F1RE GREEN SMIP
INVOICE PAID AMOUNT
AMOUNT OCASH 0CHECKJ1 OCREDITCARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building& Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM QTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE .560 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 8 PCS.1 LG I LG520EIK-A5(320W) BUYER:
INVERTER 1 8 PCS.1 ENPHASE I IQ6PLUS-72-ACM-US
ROOF TYPE I CONC.TILE DATE: ______
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD QTY 8 NA NA NA BUYER:
TILT 27' NA' NA' NA'
AZIMUTH 1 183' NA' NA' NA' DATE:
eJ ■ IE
City of Menifee
Building Dept.
AUG 14 2018
I F Received
1
N ,
NEMA 3RSI , BOX
(I'OUTRIDEE ARRAY)
AY)Y)
PV AC DISCONNECT
5'-6- 3'-04 EXTERIOR-GARAGE
UTILITY METER 8
iO MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
CITY OF MENIFEE AC COMBINER BOX
l6WLDWG AND SAFETY _ -
PLAN APPROVAL
REVIEWED BYLU
JNL Ny 49)_ '
DATE
'Aif+f@�11v�1�ts�b1{1��t4€SR@d+e be a permitfa,aan
approval of,any vide m of any wwhsim of the federal,stab or City
nyuldons and ordinances. This sK of appro*#ms must be kt$on ft z
PLA I ELEVATION B RIGHT
lebsde Until completion. ORIENTATION 4 LOT# 19
ORIGINAL BY:JIM PARKS DATE: 18.06.12
WOODSIDE HOMES:
DAKOTA AT 11670 PIERCE STREET.SUITE#100 REVIEWED BY:T. HAMMERBACHER DATE: 18.06.13
AUDIE MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION
b namasGe
SOLA!
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
6707 Winchester Circle
INDIVIDUAL 30621 SAGE CREEK DRIVE Suite O
PLOT PLAN I I/I6'=I'-0' MENIFEE.CA Boulder, 7O WWI
3OO
SYSTEM LAYOUT 303.447.0300
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE
I dB LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR
2 TBD TBD PV ROOF JUNCTION BOX.NEMA 3R SOLAR
3 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA SR,24OV,30A SOLAR
4 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR
5 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR
6 ENPHASE TBD PV BREAKER,I X 2OA-2P, I X 5A-ZP SOLAR
7 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR
8 TBD TBD SERVICE PANEL.200A BUS BLDR.ELEC.
9 TBD TBD UTILITY METER.IPH.120/24OV,200A BLDR.ELEC.10 TBD I TBD I GROUNDING ELECTRODE.UFER I BLDR.ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 38 BUS RATING AMPS 200
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40
TEMP,DELTA LOW(TELLTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS:
MOD.PART NUMBER AC MODULE SPEC L0320EIK-A5(32OW) I.DA x RMODS)= 9.36A OF CURRENT
MOD.POWER STC(P) AC MODULE SPEC WATTS(OC) 320 9.56A x 1.25= 100A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC 290 TIE-W WITH A ZOA/2P 2 SPACE PV MCKFEED BBEAHER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT(IAO) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC ULI741/IEEEI547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD.QTY BC QTY 8
BRANCH CIRCUIT OUTPUT. IMAXBC (IAC'MOD.QTY BC) AMPS(AC) 9.36
AC MODULE QUANTITY, TOTAL MOD. QTY T QTY 8
TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD. QTY T) AMPS(AC) 9.36
CONDUCTOR SIZING CALCULATIONS
1)CONDITION OF USE(COU): I (AMPACITY-TEMP.DERATE'FILL DEBATE)vs. REO'D(IMAX)
2)TERMINALS(TERM): I AMPACITY AT TERMINALS. vs.REO'D,(IMAX' 1.25)
KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A #12 CU I THWN-2 COU 30 0.76 1.0 22.80 9.36
TERM 25 25 11.70 20
B #10 CU NM-B COU 40 0.91 1.0 36.40 9.36
TERM 35 35 11.70 20
C #10 Cu NM-B COU 40 0.91 1.0 36.40 9.36
TERM 35 35 11.70 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENPHASE Q CABLE, 1-#6G.FREE AIR I CU I UL3003.DU CABLE I ARRAY I SOLAR 9
B 13-#10'.I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
C 1 3-#10.I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
M
'NEUTRAL CAPPED AND NOT USED
4 Q3
OSA/2P
I
O 6 A72
z
20A/ZP 200 N i
A B C C = 10
I I I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.56OKW
LOT#19
ORIGINAL BY:JIM PARKS DATE: 18.06.12
DAKOTA AT WOODSIDE HOMES:11870 PIERCE STREET.SUITE#100 REVIEWED BY:T.HAMMERBACHER I DATE: 18.06.13
AUDIE MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION •�
d namasG€
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
6707 Winchester Circle
INDIVIDUAL 30621 SAGE CREEK DRIVE Suite 700
PLOT PLAN 2 NTS MENIFEE.CA Boulder,CO 80301
ELECTRICAL 303.447.03DO
INSTALLATION NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.
APRIL 2016 EDITION
6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40%
8)PV PANEL HAS BEEN TESTED BASED ON UL 1703.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
11)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS.
ELECTRICAL NOTES:
GENERAL-
[)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU.
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE,
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE,
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
I5)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT J'.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:JIM PARKS DATE:18.06.12
DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T. HAMMERBACHER I DATE:18.06.13
11870 PIERCE STREET,SUITE#100
AUDIE MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION
�2namasti§
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
6707 Wincilester Circe
INDIVIDUAL 30621 SAGE CREEK DRIVE Suite 00O8
PLOT PLAN 3 NTS MENIPEE,CA Bo303. CO30001
NOTES 303.46].0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
HEM 3R JUNCTION BOX
fP OUTSIDE ARMY)
PV AC DISCONNECT
EXTERIOP.-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
[A 4C COMBINER BOX
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 9.36A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:JIM PARKS DATE:18.06.12
DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER DATE:18.06.13
11870 PIERCE STREET.SUITE #100
AUDIE MURPHY RANCH RIVERSIDE.CA 92505 REV.# BY DATE DESCRIPTION
b namasbe
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 V.FncheslaCircle
INDIVIDUAL 30621 SAGE CREEK DRIVE SURE 700
PLOT PLAN 4 NTS MENIFEE.CA Boultler,CO 80301
PLACARDS 1 303.447.0300