Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-04021
City of Menifee Permit No.: PMT18-04021 29714 HAUN RD. Type: Residential Electrical � < MENIFEE,CA 92586 ;MENIFEE MENIFEE Date Issued: 0 813 012 01 8 PERMIT Site Address: 24522 HIDDEN HILLS DR, MENIFEE, CA Parcel Number: 358-661-012 92584 Construction Cost: $6,779.00 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM,8 PANELS,8 MICROINVERTERS,2.560 KW Work: DAKOTA TR 32025 LOT 37 Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET,STE 100 760 NORTHWEST 107 AVENUE RIVERSIDE,CA 92505 MIAMI, FL 33172 Applicant Phone: 3054854110 KRISTEN MURRAY License Number. 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description ,Qtv Amount 1$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Cade or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA Bldg_Permit_Template.rpt Page 1 of 1 _ Menifee �1 DATE 08/08/2018 PERMIT/PLAN CHECK NUMBER PiAFSY027Q5 TYPE: []COMMERCIAL ❑✓ RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME POOL/SPA ❑SIGN SUBTYPE: [—]ADDITION ❑ALTERATION ❑DEMOLITION QELECiRICAL ❑MECHANICAL ❑NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES City Of Menifee Dept. DESCRIPTION OF WORK INSTALL 2.560kW ROOF MOUNTED PV SYSTEM PROJECTADDRESS 24522 HIDDEN HILLS,MEN IFEE,CA92584 Received ASSESSOR'S PARCEL NUMBER 358-661-012 LOT 37 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (951)710-1912 EMAIL RICKJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YESONO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $6.779.00 y�,,JJ// SQ FFT L SO FT APPLICANT'S SIGNATURE '7�/i.IAQ�►1. / ! L DATE 08/08/2018 CITYSTAFFUSEONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP INVOICE PAID AMOUNT w O AMOUNT C Bdn .\.lrO O CASH CHECK# O CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0 CASH 0 CHECK# 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OT 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.56OKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8 PCS.1 LG I LG3ZOEIK-A5(320W) BUYER: INVERTER 1 8 PCS.1 ENPHASE I IO6PLUS-72-ACM-US ROOF TYPE I CONC. TILE DATE: Mon SUB-ARRAY INFORMATION ARRAY 91 ARRAY#2 1 ARRAY#3 ARRAY#4 MOD OTY 8 NA NA NA BUYER: ------ TILTI IB• NA- I NA- NA° . DATE: AZIMUTH 183• NA- NA' NA° City of Menifee Building Dept. AUG 14 2018 Received i I I r � 26-10'ARRAY NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) :o PV AC DISCONNECT EXTERIOR-GARAGE ° UTILITY METER 8 MAIN SERVICE PANEL I , I—— ,OF M ON _ AC COMBINER BOX UILDINO-A-ft SAFETY DEPARTMENT PLAN AP RO AL REVIEWED BY �u DATE 'Approval of these plans shall not be construed to be a permit for,oran approval of,any violation of any provisions of the federal,state or city NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF regulations and ordinances. This set of approved plans must be kept on the N jobsite until completion. PLAN 2 ELEVATION B RIGHT ORIENTATION I LOT#37 ORIGINAL BY:JIM PARKS I DATE: 18.06.12 WOODSIDE HOMES: DAKOTA AT 11870 PIERCE STREET,SUITE#100 REVIEWED BY:T.HAMMERBACHER DATE: 18.06.I3 AUDIE MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VAnclrester Circle INDIVIDUAL 24522 HIDDEN HILLS DRIVE Suite 700 PLOT PLAN 1 1'1 6'=1'-0' MENIFEE.CA Boulder,CO 80301 SYSTEM LAYOUT I 3D3.447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 B LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 TBD TBO PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 4 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER, I X 20A-ZP, 1 X SA-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.RATING MAY VARY SOLAR B I TBD TBD SERVICE PANEL.200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER, IPH,120/240V.200A BLOB,ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. I CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAR) ASHRAE 2% 'C 38 BUS RATING AMPS 200 TEMP,AMBIENT LOW CTMIN) ASHRAE EXTR.MIN -C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 ALLOWED PV PER NEC AMPS 40 TEMP.DELTA LOW(TOELTA) TMtN-TTEST °C -27 PV OCPD DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-AS(32OW) I.DA x SNODS)= 9.36A OF CURRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(nc) 320 9.36A x 1.25, 11.704 PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-1N WITH A z0AI2P 2 SPACE PV BACKFEEO BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 /IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. GTY Bc QTY 8 BRANCH CIRCUIT OUTPUT, IMAXBC (IAc•MOD.QTY B0) AMPS(AC) 9.36 AC MODULE QUANTITY,TOTAL MOD.OTY T QTY 8 TOTAL SYSTEM OUTPUT IMAXTs I (IAC-MOD.OTY T) I AMPS(AC) 1 9.36 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY • TEMP.DERATE' FILL DEBATE)vs. REO'D(IMAx) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REO'D.(IMAX- 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACI TY W/O TEMP. FILL RESULT REO'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU I THWN-2 COU 30 0.76 1.0 22.80 9.36 TERM 25 25 IL70 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.36 - TERM 35 35 II.70 20 C #10 1 CU I NM-B COU 40 0.91 1.0 36.40 9.36 TERM 35 35 11.70 20 CONDUCTOR SCHEDULE KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENPHASE 0 CABLE, 1-#66.FREE AIR CU U1.3003.DG CABLE ARRAY SOLAR B 13-#10'. -#10 EGG I CU NM-B(ROMEX) INTERIOR I SOLAR 9 C 1 3410, I-#10 EGC I CU NM-B(ROMEX) INTERIOR ISOLAR 'NEUTRAL CAPPED AND NOT USED O O - 0 O 5 4 O SA/2P O O © 2UA/2 2 20A/ IN A B C C = 10 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM Z.560KW LOT#37 ORIGINAL BY:JIM PARKS I DATE: 18.06.12 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER I DATE: 18.06.13 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION �'a namaste SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 VAnchester Circle INDIVIDUAL 24522 HIDDEN HILLS DRIVE Suite 700 PLOT PLAN 2 NTS MENIFEE.CA Boulder,GO 80301 ELECTRICAL 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(?)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON ILL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IU ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. W NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR T0.INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS, 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT e. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:JIM PARKS DATE:18.06.12 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T. HAMMERBACHER I DATE:18.06.13 11870 PIERCE STREET.SUITE#100 AUDIE MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION �:tnamasbd .o,.e DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 24522 HIDDEN HILLS DRIVE Suire 70D PLOT PLAN 3 NTS MENIFEE.CA Boulder,CO 80301 NOTES 303.447.03DO CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.36A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:JIM PARKS I DATE:18.06.12 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T. HAMMERBACHER I DATE:18.06.13 11870 PIERCE STREET.SUITE#100 REV.# BY GATE DESCRIPTION ✓�" AUDIE MURPHY RANCH RIVERSIDE.CA 92505 namaste iOL•P DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 24522 HIDDEN HILLS DRIVE Suite 700 PLOT PLAN 4 NITS MENIFEE.CA Boulder,CO 80301 PLACARDS 303.447.0300