Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-03552
City of Menifee Permit No.: PMT18-03552 29714 HAUN RD.lA MENIFEE,CA 92586 Type: Residential Electrical MENIFEE MENIFEE Date Issued: 07/19/2018 PERMIT Site Address: 30421 VILLAGE KNOLL DR,MENIFEE, Parcel Number: CA 92584 Construction Cost: $5,931.52 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM,7 PANELS,2.24 KW Work: THE VILLAGE TR 37179 LOT 61 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE, STE 302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number.728102 LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE,#302 CORONA,CA 92879 Fee Description OQt Amount ISI Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when In violation of the Building Code or of any other ordinance of City of Mendee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_BIdg Permit Template.rpt Page 1 of 1 BUILDING &SAFETY PERMIT/PLAN CHECK APPLICATION MEN EE DATE: 7/16/2018 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER TYPE: COMMERCIAL 0 RESIDENTIAL 0 MULTI-FAMILY 0 MOBILE HOME O P@t SOAg DI$(AN SUBTYPE: G ADDITION C'ALTERATION 0 DEMOLITION O ELECTRICAL 0 IC/1 MT6vN,I WB NEW O PLUMBING 0 RE-ROOF NUMBER OF SQUARES DULL I DESCRIPTION OF WORK Solar Permit-The Village Rectahied Plan T e: ItDD '/ KW: a PCS: Master Solar Permit#: PMT17-04339 PROJECTADDRESS �T al Vl��Gt_ /��(}I ( 1,�Y- ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT L/1 TRACT 37179 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? 0 YES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 5 '►31,5a SO, FT LSQFT 6 APPLICANT'S SIGNATURE DATE -7jib // i CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITYOF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICETOTAL c • O GREEN I _ SMIP OWNER BUILDER VERIFIED 0 YES 0 NO DRIVERS LICENSE# NOTARIZED LETTER 0 YES C' NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586(951)672-6777 www.cit)(ofmenifee.us ENIFE ti.� SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.240 KW City of Menifee LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 7PCS. LG LG320EIK-A5(320W) Building Dept, BUYER: INVERTER 7 PCS.1 ENPHASE I 106PLUS-72-ACM-US - ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: f/ SUB-ARRAY INFORMATION JUL 17 2018 ttr��ii{/ ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 _ _ u `-� ;,_ I , MOD OTY 4 1 3 NA I NA BUYEeceived DATER -- TILT 00 NA' NA' AZIMUTH IBO° 27070° NA° NA° -- CITY OF MENIFEE BUILDING AND SAFETY DEPARTMENT PLAN APPROVAL 13'3' RA,REVIEWED BY LW —7I1-11 IS_ 8'-8' 14'-S'FL SHING DATE '-'Ap rovif of th se plans shall not be construed to be a permit for,Gran yak fany provisions of the federal,state orcity V rdi . This set of approved plans must he kept on the P_ SOLADECK WIRE d -- TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE { UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX dam' S'•I' S'•0' NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN I606 ELEVATION A-RIGHT N ORIENTATION 3 LOT#61 ORIGINAL BY:DAN BOWLING DATEA8.07.10 MENIFEE TOWN CENTER LENNAR: REVIEWED BY:JIM PARKS DATE:I8.07.II CORONNA,A,C CA DA4 980 I DRIVE,#302 A 92879 REVS BY DATE DESCRIPTION ,go namasGe iOtAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Wiraesler Clyde INDIVIDUAL 3042I VILLAGE KNOLL DRIVE Sulle 700 PLOT PLAN I/16'=I'-0' MENIFEE,CA Boulder,CO 80301 SYSTEM LAYOUT 303.447.GWO ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER 1 MODEL NOTES TRADE 1 7 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPRASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 2 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER 06221URS PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 2OA-2P,I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR 8 I TBD TBD SERVICE PANEL,200A BUS ELDR. ELEC. 9 1 TBD TBD UTILITY METER.[PH,120/24OV,200A ELDR. ELEC. 10 I TBD TBD GROUNDING ELECTRODE,UFER IBLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. I CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TWLTA) THIN-TTIST °C -27 PV OCPO DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG32OE1K-A5 020W) I.OA A](HODS)= 8.19A OF CURRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(oc) 320 5.19A X 1,25* 10 IA PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIHN WIiH A 20A/2P 2 SPACE PV BKKFEEO BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(AC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/$9.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(A[) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC OTY 7 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC-MOD.OTY BO AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD.OTY T OTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD.OTY T) AMPS(AC) 8.19 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE COU: I(AMPACITY-TEMP. DERATE'FILL DERATE) REO'0(IHAX) 2)TERMINALS TERM): I AMPACITY AT TERMINALS. REO'D,(IHAX-1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'O OCD TYPE DERATES DERATE DERATE (A) A USED(A) A #12 CU THWN-2 COU 30 .76 1.0 22.80 8,19 TERM 25 25 10.24 20 8 010 CU NM-8 COU 1 40 71 1.0 136.40 8.19 TERM 35 35 10.24 20 C AID CU NM-S COU 40 .91 1'0 36.40 8.19 TERM 35 35 10.24 20 CONDUCTOR SCHEDULE KEY I CONDUCTORS CU/AL I TYPE LOCATION 1 TRADE A 1-#12 ENPHASE 0 CABLE,I-#6G,FREE AIR CU UL3003.DG CABLE ARRAY SOLAR B 3-#10'.I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR ISOLAR 9 C I 3-#10,I-#10 EGC ICU I NM-B(ROMEX) I INTERIOR I SOLAR 'NEUTRAL CAPPED AND NOT USED M -- IB - 4 Q3 G 54/2P O © 20 2 20A/2 # N � G G-J A B ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#61 ORIGINAL BY:DAN BOWLING I DATE:18.07.10 MENIFEE TOWN CENTER LENNAR: REVIEWED BY:JIM PARKS I DATE:18.07.11 990 MONTECITO DRIVE,#302 REV.# BY DATE DESCRIPTION DA4 CORONA,CA 92879 rh;: Qb namasC6 sour DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 WD90ester Circle INDIVIDUAL 30421 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN 2 NTS MENIFEE.CA Boulder,CO B0301 ELECTRICAL 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(P)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING (COMPOSITION TO TILE)WILL BE A MINIMUM OF 3', II)26 GAUGE INTERLOCKING FLASHING-SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- 0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NONCURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED-PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DAN BOWLING I DATEIB.07.10 MENIFEE TOWN CENTER LE MONTECITO DRIVE.#302 REVIEWED BY:JIM PARKS DATE16.07.11 DA4 CORONA,CA 92879 REV.# UDATEDESCRIPTION f ) j�b namast6 SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 907 Winchester Cir INDIVIDUAL 30421 VILLAGE KNOLL DRIVE Suhe TOO PLOT PLAN 3 NTS MENIFEE,CA B.IEer,CO 80301 NOTES 303.4A7.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. Lo I I/ SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR - GARAGE UTILITY METER a MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING DATEf8.07.10 MENIFEE TOWN CENTER LEN MONTE[ITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE]8.07.11 DA4 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION Via namast6 ..LAP DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 V8nrllester Circle INDIVIDUAL 30421 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN 4 NTS MENIFEE,CA Boulder,CO 80301 PLACARDS 30."TD300