Loading...
PMT18-03551 City of Menifee Permit No.: PMT18-03551 29714 HAUN RD. ® MENIFEE, CA 92586 Type: Residential Electrical MENIFEE MENIFEE Date Issued: 0 711 912 01 8 PERMIT Site Address: 30409 VILLAGE KNOLL DR, MENIFEE, Parcel Number: CA 92584 Construction Cost: $5,931.52 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM,7 PANELS,2.24 KW Work: THE VILLAGE TR 37179 LOT 60 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE, STE 302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE,#302 CORONA,CA 92879 Fee Description ON Amount f51 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_BIdg__Pemdt_Template.rpt Page i of 1 BUILDING &SAFETY PERMIT/PLAN CHECK APPLICATION ;', MENIPEE � tr DATE: 7/16/2018 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER TYPE: O COMMERCIAL -'-', RESIDENTIAL O MULTI-FAMILY O MOBILE HOME C A'AdMMPPaP%IGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION 0 ELECTRICAL Q MECTANl6/�ie8 ONEW PLUMBING ORE-ROOF NUMBER OF SQUARES J I / LUI DESCRIPTION OF WORK Solar Permit-The Village Plan Type: 5 l-7 KW: PCS: Master Solar Permit#: PMT17-04339 PROJECT ADDRESS '�)bL/6'0/ UI I�l.(G.p. 'G.kjo ]1 1 Y ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT Lob TRACT 37179 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar:com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? OYES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIICNUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ So FTTL L SO,FT APPLICANT'S SIGNATURE / "'" /�`'_ DATE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL 1 a 9 3. GREEN SMIP ,- OWNER BUILDER VERIFIED O YES O0 NO DRIVERS LICENSE# NOTARIZED LETTER O YES 10 NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofmenifee.us ENIF@ ti.� SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM I CITY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.24OKW City of Menifee LOCATIONS INDICATED BY THE ILLUSTRATION. OD MULE 7 PCS.1 LG I LG320EIK-A5(3207) Building Dept, BUYER: INVERTER 1 7 PCS.I ENPHASE I IG6PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: _ SUB-ARRAY INFORMATION JUL 17 2018 —--- ARRAY#I 1 ARRAY#2 1 ARRAY#3MNA' ARRAY �y( �-,I�win MOO OTY 7 NA NAR Q c^I v A DATEBUYER "■J TILT 23° NA' NA. NA' �j �+ C AZIMUTH 270• NA' NA' F Y OF MENIFEE LDING AND SAFETY DEPARTMENTN APPROVAL REVIEWED BY 5'-0• DATE y val of these plans shall not be construed to be a permit for, A ran a o al of,any violation of any provisions of the federal,state orcity ula ions and ordinances. This set of approved plans must be kept on jobsit until completion. �z PV AC DISCONNECT p_, EXTERIOR-GARAGE------.,, #b SOLADECK WIRE UTILITY METER S TRANSITION BOX MAIN SERVICE PANEL (UNDER ARRAY) (VERIFIED BY BUILDER) A[COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 1577 ELEVATION B-LEFT ORIENTATION 1 LOT#60 MENIFEE TOWN CENTER LENNAR: ORIGINAL BY:DAN BOWLING I DATE:10.07.10 9 REVIEWED BY:JIM PARKS DATE:IB.07.11 DA4 CORONA,C CA AI 92879 DRIVE,#302 REV.# BY DATE DESCRIPTION namaste DWG TITLE: PAGE#: I SCALE: SITE LOCATION: U07 WNmester Circe INDIVIDUAL 30409 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN 1 1116'=I'-0' MENIFEE,CA Boulder,CO 80301 SYSTEM LAYOUT I 303.447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 7 LG LG320EIK-AS(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0766-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER OG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IOAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI.240.8 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,i X 20A-ZP,I X 5A-ZP SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P,RATING MAY VARY SOLAR 5 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TOD UTILITY METER, IPH, 120/240Y,200A BLDR.ELEC. IO I TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASMRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 1.17A X RMODS). 8.19A OF CW NT MOD.POWER STC(P) AC MODULE SPEC WATTS(06) 320 8.19A x I.25= 16.ZLA PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN wUM A 2911 2 SPACE P9 EA(%FEEO BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211.264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MOOULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY SC OTY 7 BRANCH CIRCUIT OUTPUT,IMAXBC (IAC°MOD.QTY BC) AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD.OTY T OTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC°MOD.OTY T) AMPS(AC) 1 8.19 CONDUCTOR SIZING CALCULATIONS I CONDITION OF USE(COU): I(AMPACITY°TEMP.DERATE°FILL DEBATE)YS.REO'D 0 ) 2)TERMINALS(TERM I AMPACITY AT TERMINALS. v5 REO'D, MAX( °1.25) KEY SIZE Cu/AL INSULATION CALL. AMPACITY W/O TEMP. FILL D RESULT RE0'D OC TYPE DERATES DERATE DERATE A) (A) USED(A) A #12 CU THWN-2 COU 30 .76 1.0 22.80 8.19 TERM 25 25 10.24 20 B #10 CU NM-B COU 40 .91 1.0 36.40 8.19 TERM 35 35 10.24 20 C #IO CU NM-B COU 40 .91 1.0 36.40 8.19 - TERM 35 35 10.24 120 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE q I-#12 ENPHASE 0 CABLE,I-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR B 1 3-#IO°, 1-#10 EGC I CU NM-B(ROMEX) I INTERIOR I SOLAR C 1 3410,I-#10 EGC I CU NM-B(ROMEX) I INTERIOR I SOLAR 9 `NEUTRAL CAPPED AND NOT USED O _ 8 0 4 m �3 0 5A/2P O 0 O6 2oa) 2 26wz N A B C C — 10 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#60 ORIGINAL BY:DAN BOWLING I DATEJ8. LENNAR: 07.10 MENIFEE TOWN CENTER REVIEWED BY:JIM PARKS JDATEAS.07.11 980 MONTECITO DRIVE,*302 DA4 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION • pl Go namaste aouB DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 WmrhesteTCirce INDIVIDUAL 30409 VILLAGE KNOLL DRIVE SUKe 700 PLOT PLAN 2 NTS MENIFEE,CA Boulder,Co 803D1 ELECTRICAL W3.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48.O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT COOE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% II)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(P)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13).AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOON12ED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT�, 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DAN BOWLING DATE18.07.10 MENIFEE TOWN CENTER Leo NAR MONTBCITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE18.07.II DA4 CORONA.CA 92879 REV.# BY DATE DESCRIPTION •1,, namasr6 Aoue DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Wln0aster Circe INDIVIDUAL 30409 VILLAGE KNOLL DRIVE Sulte 700 PLOT PLAN 3 NTS MENIFEE,CA BoulEe4COW M1 NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. PV AC DISCONNECT EXTERIOR - GARAGE SOLADECK WIRE UTILITY METER & TRANSITION BOX MAIN SERVICE PANEL-1-4 (UNDER ARRAY) (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING DATEJ8.07.10 MENI FEE TOWN CENTER 980 MONTECITO DRIVE,#302 REVIEWED SY:JIM PARKS DATE18.07.11 DA4 CORONA,CA 92879 REV.# BY DATE DESCRIPTION �ii namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION'. 6707 Winchester CI(Ue INDIVIDUAL 30409 VILLAGE KNOLL DRIVE Su Ile 700 PLOT PLAN 4 NTS MENIFEE.CA Boulder,CO 80301 PLACARDS 303.4d7.0300