Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-03550
City of Menifee Permit No.: PMTIB-03550 29714 HAUN RD.jW MENIFEE, CA 92586 Type: Residential Electrical MENIFEE MENIFEE Date Issued: 07/19/2018 PERMIT Site Address: 30415 VILLAGE KNOLL DR, MENIFEE, Parcel Number: CA 92584 Construction Cost: $5,931.52 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM,7 PANELS,2.24 KW Work: THE VILLAGE TR 37179 LOT 59 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE,STE 302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE,#302 CORONA, CA 92879 Fee Description Ply Amount($) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Marilee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE DATE: 7/16/2018 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER Cit of Menifee TYPE: COMMERCIAL )( RESIDENTIAL O MULTI-FAMILY O MOBILE HOME G P N SUBTYPE: O ADDITION O ALTERATION O DEMOLITION X ELECTRICAL O MECHANICAL 1 O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES ,J�UL 17 2018 DESCRIPTION OF WORK Solar Permit-The Village Received Plan Type: 1105 KW: 1a "a PCS: Master Solar Permit#: PMT17-04339 PROJECTADDRESS JO� '� �I ll�a�-e. �y,bl� n r ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT 55 TRACT 37179 OWNER NAME Lennar Homes Of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? O YES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATEQLIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 5"t 31'5a SQ FT L So FT APPLICANT'S SIGNATURE DATE I ( � CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITYOF MENIFEE BUSINESS LICENSENUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL gq.3 ,GJv GREEN _ SMIP — OWNER BUILDER VERIFIED 10 YES 0 NO DRIVERS LICENSE It NOTARIZED LETTER 0 YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofmenifee.us ENIFE SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.240KW LOCATIONS INDICATED BY THE ILLUSTRATION, MODULE 7 PCS.1 LG I L6320EIK-AS(320W) BUYER: --- INVERTER 1 7 PCS,1 ENPHASE I 1CI6PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: ----—_______— SUB-ARRAY INFORMATION r7 ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 CItY �t Menitee MOD CITY 7 1 NA I NA NA Building Dept' BUYER: TILT I 16° I NA' I NA' NA' AZIMUTH 270° NA' NA. NA* JUL 17 2018 DATE: —____—_—_---_—___________ Received CITY OF MENIFEE BUILDING AND SAFETY DEPARTMENT PLAN APPROVAL i REVIEWED BY DATE Xloftnhse plans shall no4 he construed to be a pzrmitfor,oran violation of any provisions of the federal,state or city ordi antes. This set of approved plans must be kept on the ple on. — _ t SOLADECK WIREJ TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECTEXTERIOR-GARAGE UTILITY METER a MAIN SERVICE PANEL (VERIFIED BY BUILDER) t(- AC COMBINER BOX 5•-6- 3• NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 1705 ELEVATION D-LEFT ORIENTATION I LOT#59 LENNAR: ORIGINAL BY:DAN BOWLING DATE) .07.10 MENIFEE TOWN CENTER REVIEWED BY:JIM PARKS DATE:IB.07.11 DA4 CO NA,CA I9Z DRIVE,#302 CORONA,CA 92879 REV.k BY DATE DESCRIPTION •i a namastc roue DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Winchester Cutle INDIVIDUAL 30415 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN 1 1/16'=V-0' MENIFEE.CA Boulder,CO 80301 SYSTEM LAYOUT I 303.447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL I NOTES TRADE 1 7 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 I RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 Ct1TLER-HAMMER DG221LRB PV AC DISCONNECT,NEMA 3R.240V,30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IOAMI-240 PV DATA MONITOR,240Y SOLAR 5 1 ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 6 1 ENPHASE TED PV BREAKER,I X 20A-2P,IX 5A-2P SOLAR 7 1 CUTLER-HAMMER TED PV BREAKER,1 X 20A-2P,RATING MAY VARY SOLAR 8 I TOO TED SERVICE PANEL,200A BUS BLDR. ELEC. 9 1 TED TED UTILITY METER,[PH,120/240Y,200A BLDR. ELEC. 10 I TED TED GROUNDING ELECTRODE,UFER IBLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM I UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT I AMPS I ZOO TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC I AMPS 140 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED I AMPS 120 MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC L0320EIK-A5(320W) I.I]a x]IM009)° 8.I9A OF[�M MOD.POWER STC(P) AC MODULE SPEC WATTS(0C) 320 6.19A a 1.25. 1oY<a PEAK OUTPUT POWER_STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A.P PO 2 SPACE PV BAUFEED BRA!IER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT OAC) AC MODULE SPEC AMPS AC 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60,5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE 1 COMPLIANCE AC MODULE SPEC ULI741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD, OTY BC OTY 7 BRANCH CIRCUIT OUTPUT,INAXBC (IAC'MOD.QTY BC) AMPS(AC) 8J9 AC MODULE QUANTITY.TOTAL MOD.OTY T OTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD. OTY T) AMPS CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE COU): I(AMPACITY•TEMP. DERATE -FILL DERATE)YL REO'D DMA%) 2)TERMINALS(TERM): I AMPACITY AT TERMINALS. VS.REG-D.(IMAX- 1.25) KEY SIZE CU/AL INSULATION TYPE AMPACITY W/O TEMP. FILL RESULT REO'0 OCD TYPE DERATES DERATE DERATE (A) (A) USED A A *2CUUTHWN-2 COU 30 =1.022,806.19 M 2510.24 20 8 NN-B COu 40 8,19 TERM 3510.24 20 C NM-B COU 40 8.19 ERM 3510.24 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL I TYPE 1 LOCATION TRADE A 1-4,12 ENPHASE Q CABLE,1-06G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR B 13-#IO•,I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR 9 C 1 3-#10, I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR -NEUTRAL CAPPED AND NOT USED M — 8 4 33 O5A/2P I 7 O ©FT20m ZOA N G GJ ROOF I EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2,24OKW LOT#59 ORIGINAL BY:DAN BOWLING I DATE:18,07.10 MENIFEE TOWN CENTER LENNAR: REVIEWED BY:JIM PARKS DATE:18.07.11 980 MONTECITO DRIVE,#302 DA4 CORONA,CA 92079 REV.# BY DATE I DESCRIPTION Ito namast;6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 30415 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN 2 NTS MENIFEE,CA Boulder,CO 80301 ELECTRICAL I 303447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT, 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH*)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% IU 26 GAUGE INTERLOCKING FLASHING'SIOEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(0 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL.N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED A80VE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. SIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION, ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH, PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730, 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS, 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122, 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS, 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING, BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- I9)INSTALLATION SHALL BE COMPLETED INA NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DAN BOWLING DATE18.07.10 MENIFEE TOWN CENTER LENNAR TECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE18.07.11 980 MODA4 CORONA.CA 92879 REV.# BY DATE DESCRIPTION a I Qb namasG6 !CLAY DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 W.r nler Circe INDIVIDUAL 30415 VILLAGE KNOLL DRIVE SUHe 700 PLOT PLAN 3 NTS MENIFEE,CA Boulder,CO8D301 NOTES 303.4A7.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR - GARAGE UTILITY METER 8, MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING DATE18.07.10 MENIFEE TOWN CENTER 980 MONTECITO DRIVE, 5302 REVIEWED BY:JIM PARKS DATE18.07.1I DA4 CORONA.CA 92874 REV.: BY DATE DESCRIPTION �(_ eta namast6 SGLAR DWG TITLE: PAGER: I SCALE: SITE LOCATION: 6707 Winchester Circe INDIVIDUAL 304I5 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN A NTS MENIFEE.CA Boulder,CO 80301 PLACARDS 301"7.0300