Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-03547
City of Menifee Permit No.: PMT18-03547 29714 HAUN RD. Type: Residential Electrical MENIFEE, CA 92586 MENIFEE MENIFEE Date Issued: 07/19/2018 PERMIT Site Address: 30401 VILLAGE KNOLL DR, MENIFEE, Parcel Number: CA 92584 Construction Cost: $5,931.52 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR SYSTEM,7 PANELS,2.24 KW Work: THE VILLAGE TR 37179 LOT 52 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE,STE 302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE,#302 CORONA,CA 92879 Fee Description ON Amount I$) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permp_Templale.rpl Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE r, 'L ji DATE: 7/16/2018 PERMIT/PLAN CHECK NUMBER 9M' PLANNING CASE NUMBER City o enI ee TYPE: O COMMERCIAL O RESIDENTIAL c' MULTI-FAMILY O MOBILE HOME 0 PO SUBTYPE: 0 ADDITION O ALTERATION O DEMOLITION O ELECTRICAL 0 MECHANICAL ONEW OPLUMBING C, RE-ROOF NUMBER OF SQUARES JUL 17 2018 DESCRIPTION OF (WORK Solar Permit-The Village Receaved Plan T e: 1 L2S KW: a'a 1 PCS: Master Solar Permit#: PMT17-04339 PROJECTADDRESS Ul llj )2-n61t -by . ZIP 92584 u ASSESSOR'S PARCEL NUMBER LOT TRACT 37179 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? O YES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ S,Q, FTT' L SO FT APPLICANT'S SIGNATURE v�' - DATE I lu/I tS- CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITYOF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL I C,;q GREEN I — SMIP ' OWNER BUILDER VERIFIED YES NO DRIVERS LICENSE# NOTARIZED LETTER C' YES NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee,CA 92586(951)672-6777 www.cityofmenifee.us ENIFE SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 0 SYSTEM SIZE 2.240 KW MFR. MODEL City of Menifee ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 7 PCS.I LG I LG320EIK-A5(32OW) Building Dept' BUYER: INVERTER 7 PCS.1 ENPHASE I 106PLLIS-72-ACM-US ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY 2�10 DATE: SUB-ARRAY INFORMATION JUL 17 L UU ARRAY#1 ARRAY#2 ARRAY#3 ARRAY 04 MOD OTY 5 2 NA NA Q'\ P d DATEBUYER AZIM OFFICE CUPY TILTUTH SO 70 NA' NA: Q r Y v AZIMUTH Ie0° 270° 1 NA- NA° CITY OF MENIFEE BUILDING AND SAFETY DEPARTMEN PLAN APPROVAL REVIEWED BY I6'-9'ARRAY ATE 7'-0' 17'-7'FLASHING 'Approval of these plans shall not be construed tobea permitfo r, ran -— — pproval of,any violation of any provisions of the federal,sons and ordinances. This set of approved plain must be k otate a ity egulatin the I et obsite until completion. t � I I I 1 SOLADECK WIRE I t TRANSITION BOX I (UNDER ARRAY) _ PV AC DISCONNECT '- EXTERIOR-GARAGE ✓rj UTILITY METER 8 MAIN SERVICE PANEL a (VERIFIED BY BUILDER) AC COMBINER BOX 1 3' 5'•6' -Fri; �.Ilt,l iai NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1705 ELEVATION A-RIGHT ORIENTATION 3 LOT#52 MENIFEE TOWN CENTER LENNAR: ORIGINAL BY:DAN BOWLING I DATE:18.07.10 REVIEWED BY:JIM PARKS DATE:18.07.11 DA4 CORONA, NA,CA 92ECTO DRIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION .I u namast;e SYLAF DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 30401 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN 1 1/16-=1'-0' MENIFEE,CA Boulder,CO B0301 SYSTEM LAYOUT 1 303,447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY CITY I MANUFACTURER MODEL NOTES TRADE 1 7 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 2 RSTC/SOLAOECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 3 1 CUTLER-HAMMER D0221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IOAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-2 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,1 X 2OA-2P,I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR 8 I TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 9 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TOELTA) TMIN-TTE9T °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER - AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC L6320EIK-AS(32OW) 1.17A x AMODS)- 6.19A 6F CURRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(W) 320 S.NA x 1.25• I6.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WTR A 20a2P 2 SPACE PV BACXFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/ IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AU 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.CITY Bc OTY 7 BRANCH CIRCUIT OUTPUT,IMAXBC (IAC'MOD.OTY BC) AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD. CITY T OTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC°MOD.CITY T) AMPS(AC) 8.19 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE (COU); (AMPACITY- TEMP.DERATE•FILL DERATE)VS. REO'D(TMAX) 2 TERMINALS(TERM): AMPACITY AT TERMINALS. .REO'D.(WAX- 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D QCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 .76 1.0 22.80 8.19 TERM 25 25 10.24 20 B #10 CU NM-2 COU 40 .91 1.0 36.40 8.19 TERM 35 35 10.24 20 C #10 CU NM-B COU 40 .91 1.0 36.40 8.19 TERM 35 35 10.24 1 20 CONDUCTOR SCHEDULE KEY CONDUCTORS I CU/AL TYPE LOCATION TRADE A I-#12 ENPHASE Q CABLE, 1-#6G.FREE AIR CU UL3003,DG CABLE ARRAY SOLAR B 3410'.1-#10 EGC CU NM-S(ROMEX) INTERIOR SOLAR 9 C 3-#10, 1410 EGC CU NM-S(ROMEX) INTERIOR SOLAR RI 'NEUTRAL CAPPED AND NOT USED M 0 O O 8 ,. 4 m 3O c sazP Oj © 20a zoaz N G G — ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2 240KW LOT#52 MENIFEE TOWN CENTER LENNAR: ORIGINAL BY:DAN BOWLING IDATE18.07.10 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:18.07.11 ' DA4 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION A ta 7 e namaste soux DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 WOMesler Circle INDIVIDUAL 30401 VILLAGE KNOLL DRIVE Suite 700 PLOT PLAN 2 NTS MENIFEE,CA Boulder,CO 80301 ELECTRICAL I 303.947.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48.O.C. Z)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH&)SPACE BETWEEN PY MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 11)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 09 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ' 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION, ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC, 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90•C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SMALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10% BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY-DAN BOWLING DATE18.07.10 MENIFEE TOWN CENTER 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATEIS.D7.11 DA4 CORONA,CA 92679 REV.# BY DATE DESCRIPTION to nomast,AR .a,AR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 V%ri ester Clyde INDIVIDUAL 30401 VILLAGE KNOLL DRIVE Sete 700 PLOT PLAN 3 NTS MENIFEE,CA Boulder,CO 8031 NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING 1S SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. -IT SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR - GARAGE UTILITY METER & MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8.19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING DATE18.07.10 980 MONTECITO DRIVE,II302 MENIFEE TOWN CENTER : REVIEWED BY:JIM PARKS OATE18.07.11 80 DA4 CORONA,CA 92879 REV.R BY DATE DESCRIPTION Iti Qb namasr6 SOLAR DWG TITLE: PAGE K: I SCALE: SITE LOCATION: 6707 V0n&ester Cirde INDIVIDUAL 30401 VILLAGE KNOLL DRIVE SuOe 700 PLOT PLAN 4 NTS MENIFEE.CA Boulder,CO 80301 PLACARDS 300.447.03DD