PMT18-03312 City of Menifee Permit No.: PMT18-03312
29714 HAUN RD.
�f Ai' MENIFEE, CA 92586 Type: Residential Addition
MENIFEE MENIFEE Date Issued: 0710 3/2 01 8
PERMIT
Site Address: 29626 AVENIDA DE SERENO, MENIFEE, Parcel Number: 336-261-002
CA 92586 Construction Cost: $8,000.00
Existing Use: 1 &2 Family Residence Proposed Use:
Description of INSTALL 6'x 90 L FT AND 6'x 80 L FT AND 6'x 5.6 L FT CITY STD BLOCK WALL WITH 2 PILASTERS
Work:
Owner Contractor
HEATHER&DANIEL BUSTAMANTE
29626 AVENIDA DE SERENO
MENIFEE, CA 92586
Applicant License Number:
HEATHER&DANIEL BUSTAMANTE
29626 AVENIDA DE SERENO
MENIFEE, CA 92586
Phone:9514588831
Fee Description Oty, Amount lSl
Building Permit Issuance 1 27.00
Wall/Fence,standard 1 83.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Building 1 4.15
$117.15
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg Permit Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractor's State License Law for
Professions Code and my license is in full farce and effect. the following reason:
License Class License No. By my signature below I acknowledge that,except for my personal residence
Expires Signature in which I must have resided for at least one year prior to completion of
improvements covered by this permit.I cannot legally sell a structure that I
WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in Its entirety by
❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of self-Insure for workers 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which
www.lexinfo.ca.¢ov/calaw.html.
this permit is issued.
Policy# Date
❑I have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT
section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property
this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this
number are: application and the information I have provided is correct.I agree to comply
with all applicable city and county ordinances and state laws relating to
Carrier building construction.I authorize representatives of this city or county to
Policy# Expires gnt the. we identi i ro rtyforin ction purposes.
(This section need not to be completed is the permit is for one-hundred _ --7 ,3 ,�"
dollars($100)or less `f - Date /AA `A
PROPE OWNER OR A ORIZED GE
❑I certify that in the performance of the work for which this permit is issued,
I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE#
workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the workers compensation provisions of Section 3700 of the Labor
Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a
Applicant Date mixture containing a hazardous material equal to or greater that the
amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ❑No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN r o ion occupant require a permit for the construct modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SC ion or See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines
CONSTRUCTION LENDING AGENCY ❑Yes ❑No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is Issued outer boundary of a school?
(Section 3097 Civil Code) ❑Yes o No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm under penalty of perjury that am exempt from the permitting checklist.I understand my requirements under the State of
Contractors License Law for the reason(s)indicated below by the California Health al Safety Code,Section 25505 and.25534 concerning
checkmark(s)I have placed next to the applicable items)(Section 7031.5 hazardous material reporting.
Business and Professions Code).Any city or county that requires a permit to oYes ❑No Date
construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT
issuance,also requires the applicant for the permit to file a signed statement
that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING fRRPI
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500), managers who do the paint-disturbing work themselves orthrough their
❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.epa..xov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved forthe purpose of sale. o No EPA Lead-Safe Certified Firm is required for this project because:
❑I,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
}
WX6
ien'fee
DATE PERMIT/PLAN CHECK NUiNBER Q
TYPE: O COMMERCIAL * RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK \ I
r City of Me ifee
c� a ��--??rr�� ept.
PROJECTADDRESS Q96a 9 QVP-Y7\. C�Z � mClc� ZIP (39FJ L9 JUL 0
018
ASSESSOR'S PARCEL NUMBER LOT TRACT
OWNER NAME �Y'j Cl� `(�C ed
ADDRESS r t,q (� sjoe kzz
PHONE �gcj1 5� - p��l EMAIL
APPLICANT NAME
ADDRESS O(�kJaLA ga5$\,9
PHONE -1�� LA' JD- '$9J EMAIL -zQVi6a�9
CONTRACTOR'S NAME OWNER BUILDER? O YES O NO
BUSINESS NAME
ADDRESS
PHONE EMAIL
CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION
VALUATION$ S FT LSQFT
APPLICANT'S SIGNATUR DATE
TTY STAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
-
BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY:
PERMIT FEE 5 SMIP _ GREEN _
PLAN CHECK FEE INVOICETOTAL 11
OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES Cl NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-5777
www.cityofmenifee.us
FOOTING OPTION "A" FOOTING OPTION "B"
I y of Menife
#4 HORIZONTAL REBAR Dept.
(USE BOND BEAM BLOCK) J U L 0 3 2018
<1 6" OR 8"BLOCK IaC ' Y e
"H,. H"
HEIGHT FROM TOP #4 HORIZONTAL AT 32"MAX.O.C. HEIGHT FROM TOP
OF FOOTING (USE BOND BEAM BLOCK) OF FOOTING
SEETABLE"A" SEETABLE"B"
FOR REBAR SIZE FOR REBAR SIZE
AND SPACING ANDSPACING
(LOCATE REBAR IN CENTER OF CELU (LOCATE REBAR IN CENTER OF CELU
FINISH GRADE
(1)-#4 REBAR
�IIII CONTINUOUS I_ - - -
12" 1p^ (2)-#4 REBAR 12"
IIIIIIII CONTINUOUS jlil- 10" O
=61IN 1 _
REVERSE --�."
DIRECTION OF (F�ING WIDTH) II' I (FOOTIING WI / A
HOOK ON EVERY , V
OTHER REBAR SEETABLE"A" SEETABLE"B"
ALL FOOTINGS ADJACENT TO
TABLE "A" SLOPES TO BE AT LEAST 5'TO TABLE uBR
DAYLIGHT AS SHOWN BELOW.
VERTICAL „ „ VERTICAL
REINFORCEMENT H', W', REINFORCEMENT
3' 17" #4 @ 48" O.C. 3' 19" #4 @ 48" O.C. O
4' 20" #4 @ 48" O.C. z. 4' 22" #4 @ 48" O.C.
5' 23" #4 @ 48" O.C. 5' 29" #4 @ 48" O.C.
6' 29" #4 @ 24'' O.C. eoo.M 90 6' 34" #4 @ 24" O.C.
FOOTING S MIN.
low
NOTES: CHECK WITH THE BUILDING DEPARTMENT TO
1)THIS DESIGN DOES NOT ALLOW GRADE DIFFERENTIALS OF VERIFY IF A BUILDING PERMIT IS REQUIRED.
MORE THAN 6"ON OPPOSING SIDES OF THE WALL. THIS IS WHEN A PERMIT IS REQUIRED,THE FOLLOWING
NOT A RETAINING WALL. INSPECTIONS ARE REQUIRED:
2)FENCE HEIGHTS ARE REGULATED-CONSULT ZONING 1)FOOTING;EXCAVATION TRENCH CLEAN WTTH
REGULATIONS BEFORE BEGINNING CONSTRUCTION. STEEL IN PLACE AND SUPPORTED 3"ABOVE AND
3)NO WATER COURSE OR NATURAL DRAINAGE SHALL BE AWAY FROM THE SURROUNDING EARTH/DIRT.
OBSTRUCTED. 2)REBAR/PRE-GRO ..RONQRFAMREBARAND
4)GROUT ONLY THE CELLS CONTAINING REBAR. THIS WALL VERTICAL REBAR IN P E-INSPECTION PRIOR TO
IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. PLACING GROUT. CITY
1 OF MEHIFEE
5)ALL REBAR TO BE ASTM SPEC.A615,GRADE 40 MINIMUM. 3)F_INAL;AFTER GROUT I LI P IC 0-P PRIOR
AND SA ETY[
6)ALL REBAR LAP SPLICES TO BE 24" I MINIMUM. DECORATIVE CAP PI M
7)ALL MASONRY UNITS TO BE ASTM C•90 GRADE N. FLAB APPROVAL
8)REBAR TO 13E CENTERED IN MASONRY CELLS.
WESTERN RIYERaRJE COUNTY CODE I FORMRY PROGRAM
'SEE PAGE 2 FOR ADDITIONAL INFORMATION' Adp crry F�,.�.0
DISCLAIMER: NIF BUILDIN Y
ALTERNATE DESIGNS MAY BE POSSIBLE
WHEN PROVIDED WITH AN ENGINEERED lw
FREESTAN NC BLp�K WALL
ANALYSIS. USE OF THIS STANDARD DESIGN - Tova o these plans shall n be constn
IS AT THE USER'S RISK AND CARRIES NO
IMPLIED OR INFERRED GUARANTEE AGAINST (951)6726777 29714HAUNR Pf.dWg04*ofany ovisiorls(
FAILURE OR DEFECTS. of*=FAx(951)67938432/?A/2014 WWW. F .US PAGEf OF2f
REBAR PLACEMENT
ILLUSTRATION FOOTING OPTION B
(TYPICAL)
ALL REBAR SPLICES
2411 MIN. OVERLAP .........
......... .......
(TYPICAL)
ONLY CELLS AND BOND BEAM
COURSES WITH REBAR TO BE
GROUTED
(DO NOT SOLID GROUT ENTIRE WALL-USE
GROUT STOP MESH AS APPROPRIATE)
A 33:11143M 10 YTIO (TYPICAL)
ALL REBAR SHALL HAVE A
MINIMUM OF 3" CONCRETE
YT:PAZ 0114A 0141G.111LIS
jAVC)AgqA AAA COVER AT FOOTINGS
DESIGN PARAMETERS: WESTERN RPIERSIDE CouN'ry CODE UNiroRmrry PROGRAM
AGjj, LIRE(PSF) 30 ar"ef CITY OF MENIFEE
-.PASSi S�3 BffAKAGKF) =150 BUILDING DEPARTMENT
COEFFICIENT OF FR[CTIpN =0.25 ✓sijjNWiiz: !
ALLOWABLE SOIL BEARING(PSF) =1500
WIND=80 MPH.EXPOS EC FREESTANDING BLOCK WALL
�%J4, 30ILPROFILE=50 (951)6726777 29714 HAUN ROAD,MENIFEE.CA 92586
FAX(951)679-3843 2/24/2014 WWW.CITYOFMENIFEE.US PAGE20F2
TOP VIEW
City of Menifee
FOOTING
I I
. .•
Building Dept. ....L,
BLOCK
27" GROUT JUL 0 3 2018
0' STEEL RE
v J
'Received I
AR
PLACEMENT
r- 27„ � ILLUSTRATION
SECTION VIEW
I I
BLOCK -
(12"X 12"OR 16"X 16") -I--'
I
I I
SOLID GROUT
MIN.24"
6' (4)-#4REBAR REBAR
MAX ii[i (ONEATEACHCORNER) OVERLAP I _
ALL FOOTINGS ADJACENT TO
SLOPES TO BE AT LEAST&TO _-
DAYLIGHT AS SHOWN BELOW. - ---
MIN 24"
REBAR
OVERLAP .. ... , S�02r -
GRADE I BOTTOM
I AF
BOOFOM 5'MIN.
4" _ — FOOTING •
LIMITATIONS:
FOOTING neaAx sHw.L 1 PILASTER SPACING SHALL NOT EXCEED 20 FT.WHEN OTHER INFILL FENCING
HAVE A MM.6"LGNG
29' HOOKA Ar . IS ATTACHED.
16" C0
�0173"- 2 ONLY OPEN TYPE FENCING(SUCH AS WROUGHT IRON)MAY BE ATTACHED TO
PILASTERS. SOLID TYPE FENCING MAY NOT BE ATTACHED TO PILASTER.
3.GATES AND DOORS ATTACHED TO PILASTER ARE LIMITED TO 200#MAX.
WEIGHT AND 4 FT.MAX.WIDTH PER PILASTER.
4.THIS PILASTER DESIGN IS INTENDED TO BE USED ONLY AS A FENCING
—27" ►I FEATURE AND IS NOT INTENDED TO SUPPORT A""11-IM i n
5.FENCE HEIGHTS ARE REGULATED-CONSULT ZONING REGULATIONS BEFORE
CHECK VIRCH THE BUILDING DEPARTMENT BEGINNING CONSTRUCTION.
TO VERIFY IF A BUILDING PERMIT IS REQUIRED. 6.INSTALLATION OF ELECTRIC CIRCUITS,CONDUIT,qQgu URES
WHEN A BUILDING PERMIT IS REQUIRED, REQUIRE ELECTRICAL PERMITS AND INSPECTIO(` Ac I MC1�
THE FOLLOWING INSPECTIONS ARE ALSO REQUIRED: 7•FOOTINGS TO BE PLACED IN UNDISTURBED SOIL OR PROPERLY COMPACTED
1)FOOTING;EXCAVATION TRENCH CLEAN WITH STEEL AND ENGINEERED FILL-
IN PLACE AND SUPPORTED 3"ABOVE AND AWAY FROM 8.FOR DESIGN PARAMETERS,SEE FREESTANDING BLOCK WALL STANDARD.
THE SURROUNDING THE EARTH/DIRT. WESTERN RIVERSIDE COUNTY CODE UNIFDRMITY OG
2) REBAR/PRE-GROUT; VERTICAL REBAR IN PLACE- (:I770
INSPECTION PRIOR TO PLACING GROUT. MENiffifigIM
Ie
3)FINAL;AFTER GROUT IS PLACED-PRIOR TO ANY BUILDING DEPARTMEOTE
DECORATIVE CAP PLACEMENT.
DISCLAIMER: �� MASON}2�14�FLA �
ALTERNATE DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH the federal,
AN ENGINEERED ANALYSIS.USE OF THIS STANDARD DESIGN IS (g51)672-6777
AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED 29714 HAUN ROA� �Ilitf♦0,1
GUARANTEE AGAINST FAILURE OR DEFECTS. FAX(951)679-3843 2/Z4/2014 I W W W.CITYOFMENIFEEUS I PAGE 1 OF
OFFICE COPY _p _
0
�
W!
ul C N N
E
N D
s s
� rn en •� d � � d
O
� o m
y
O T N
Q C O A A H
' ^� O Z Z O O
O y m
I{ W e
Z u l
a � U m_a CLfill
� �7-
oL �
� v
E
�Gtv e(IT
a
x �
3 M
- -llbM Ma114 1'Iro� ulyglx�