Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-03060
City of Menifee Permit No.: PMT18-03060 ` 29714 HAUN RD. 1 ® MENIFEE,CA 92586 Type: Residential Electrical MENIFEE MENIFEE Date Issued: 0810712018 PERMIT Site Address: 28581 WEDELIA ST, MENIFEE, CA 92584 Parcel Number: 333-651-017 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582-HERITAGE HEIGHTS Work: 10 MODULES, 10INVERTERS,3.20 KW LOT 95 PLAN 2686 Owner Contractor LENNAR HOMES OF CALIFORNIA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE SUITE 302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant License Number:728102 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Phone:9518173539 Fee Description Qtv Amount 1E) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Perrnit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE - 4JL. "SYAW-iY DATE: 6/12/2018 PERMIT/PLAN CHECK NUMBER V PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Heritage Heights Master Permit#-PMT17-00129 Kw: 13, 90 PCs: 10 Plan: !9 PROJECTADDRESS C'?15$' Wed-elteL ,Sf. q ZIP 92584 ASSESSOR'S PARCEL NUMBER ��' . U51 . D(.—I LOT - 15 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANTNAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 5613.76 SQQ,(F�T L SO FT APPLICANT'S SIGNATURE �S) V .W�- DATE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ' L)IP—AAI'5;'c!' DV�✓ INVOICETOTAL -'Cl J 1C1J GREEN I.CSO SMIP �. OWNER BUILDER VERIFIED O YESK NO DRIVERS LICENSE# NOTARIZED LETTER O YES C NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofinen ifee.us NL ti,� SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM QTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.200 NW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS. LG I LG320EIK-A5(320W) BUYER: INVERTER ID PCS.1 ENPHASE I 1O6PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#MNA' ARRAY#3 ARRAY#4 MOD OTY 10NA NA BUYER: TILT ANA. NA' AZIMUTH 177° HA' M. DATE: CMMRAI LJLw W $ - � c c Q m � o Z Q S u a s ax w € a= Me y KQ a sda - W d G � 0 0 y � d = O Q O - � U � W a « 4. o LW y Q t lL C) y d wZ Q 00 a = a. Q c SOLADECK WIRE UJI LL Z Q v o TRANSITION BOX O V R (UNDER ARRAY) Z W 7. ' c PV AC DISCONNECT m g w Q c' "u, EXTERIOR-GARAGE Q o UTILITY METER 6 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION C-R ®Z ORIENTATION 4 LOT#95 HERITAGE HEIGHTS LENNAR: ORIGINAL BY:ARTHUR HICKS I DATEA8.04.2L 980 MONTECITO DRIVE,#302 REVIEWED BY:DUSTIN LANNING I DATE:I8.04.24 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasa6 DWG TITLE: PAGE#: SCALE: tore INDIVIDUAL SITE LOCATION: 6707 V✓�nchesler Circle 28581 WEDELIA STREET Suite 700 PLOT PLAN 1 1/16'- 1'-0' MENIFEE.CA Boulder,CO 00301 SYSTEM LAYOUT 303.447,0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 10 LG LG320EIK-A5(32OW) ACPV MODULE W/ INTEGRATED ENPHASE IO6PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR L I ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 2OA-2P,I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER.I X 2OA-2P.RATING MAY VARY SOLAR 8 I TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 9 1 TBD TBD UTILITY METER, IPH, I20/24OV,200A BLDR. ELEC. 10 1 TBD TBD GROUNDING ELECTRODE.UFER I BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALL UNIT DETAIL ITEM I UNIT I PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC I AMPS 1 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST 'C -27 PV OCPD DEVICE USED I AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD, PART NUMBER AC MODULE SPEC LG320EIK-A5 WOW) L,K IO(MODS)= IIJOA OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 IIJOA X 1.25= I4.63A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREDUENCY'I RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY♦ AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AL MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC OTY ID BRANCH CIRCUIT OUTPUT.IMAXBC (IAC'MOD.QTY 90 AMPS(AC) 11.70 AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 10 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD. OTY T) AMPS(AC) 11.70 CONDUCTOR SIZING,CALCULATIONS 0 CONDITION OF USE(COU): (AMPACITY ' TEMP.DERATE•FILL DERATE)Y . REDID(IMAX) 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.VS. REQID,(IMAX• 1.25) KEY SIZE CU/AL INSULATION CALL, AMPACITY IWO TEMP. FILL RESULT REOT OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN'2 COU 30 .76 1.0 22.80 11..L TERM 25 25 14.63 20 B #10 CU NM-0 COU 40 .91 I.0 36.40 11.70 TERM 35 35 14.63 2D ( #10 1 Cu NM-B COU LO .91 TO-- 36.40 11.70 TERM 35 35 14.63 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENPHASE Q CABLE,146G.FREE AIR ICU I UL3003,DG CABLE I ARRAY BOLAR B 1 3410-. I-#ID EGC I Cu I NM-B(ROMEX) I INTERIOR ISOLAR 9 C 3-#10.1-#10 EGL I CU I NM-B(ROMEX) I INTERIOR ISOLAR _ 'NEUTRAL CAPPED AND NOT USED O OB 5 4 e 0 OSN2P O 1 7 O © mnra 30A2 IN G G G T ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.200 KW LOT#95 ORIGINAL BY:ARTHUR HICKS I DATE:18.04.24 HERITAGE HEIGHTS LENNAR: 980 I DRIVE,#302 REVIEWED BY:DUSTIN CANNING DATE:18.04.24 CORONNA.A.C LA A 92879 REV.# BY DATE DESCRIPTION namast6 ReLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VSuite7 O CirciD INDIVIDUAL 28581 WED A STREET Sul(BO8 PLOT PLAN 2 NTS MENIFEE,CA BGYIH.. 702100 ELECTRICAL 303.44Z0300 INSTALLATION NOTES; SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48-O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING.TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH({')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES.(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. ID)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% ID 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STILK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO.INSTALLATION. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS, 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS,WIRING.SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SMALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110,26. ORIGINAL BY:ARTHUR HICKS DATE18.04.2 LENNAR: 4 HERITAGE HEIGHTS REVIEWED BY:DUSTIN LANNING DATE18.04.24 980 MONTECITO DRIVE.#3D2 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasb6 +mee DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707Vdnchester Cir o INDIVIDUAL 28581 WEDELIA STREET Suite 700 PLOT PLAN 3 NTS MENIFEE.CA Boulder,CO BD3Di NOTES 307.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION 604 WNGER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE IRILITY METER 0 MAIN SERVICE PA (VEGIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:ARTHUR HICKS DATEIB.O4.24 HERITAGE HEIGHTS LENNAR: I DRIVE,#302 REVIEWED BY:DUSTIN LANNING DATE:IB.04.24 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namasb6 DWG TITLE: PAGE*: I SCALE: sir LAe SITE LOCATION: 6707 Vde7 Circle INDIVIDUAL 2858I WEDELIq STREET SuBe 700 PLOT PLAN L NITS MENIFEE,CA 80301 Boulder.303.4 CO PLACARDS 303.447.0300300