PMT18-03058 City of Menifee Permit No.: PMT18-03058
29714 HAUN RD.lA
MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE MENIFEE Date Issued: 08/0712018
PERMIT
Site Address: 28550 WEDELIA ST, MENIFEE,CA 92584 Parcel Number: 333-650-009
Construction Cost: $5.613.76
Existing Use: Proposed Use:
Description of SOLAR TR 31582-HERITAGE HEIGHTS
Work: 7 MODULES,7 INVERTERS, 2.24 KW
LOT 18 PLAN 1678
Owner Contractor
LENNAR HOMES OF CALIFORNIA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DRIVE SUITE 302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant License Number.728102
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Phone:9518173539
Fee Description O_yt Amount ISl
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Perrri t_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION . MEN.IFEE..
DATE: 6/12/2018 PERMIT/PLAN CHECK NUMBER
PLANNING CASE NUMBER
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Heritage Heights Master Permit#-PMT17-00129
Kw: A
q.. ay PCs:
PCs: --I L Plan: LP-]
PROJECEADDRESS 2855b �gjta J ], ZIP 92584
ASSESSOR'S PARCEL NUMBER (3 J —V" F)O- OnV 0[OT TRACT 31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella lennar.com
APPLICANT NAME Lennar Homes of California Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO
BUSINESS NAME
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 5613.76 SQ FT L SQ FT,,,, f
APPLICANT'S SIGNATURE6 JJ
� DATE `-0 11 3 {f L 6 p
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE 1
INVOICETOTAL ZOI GREEN SMIP
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777
www.c i tyo f in e n i fe e.u s
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.240 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 7PCS. LG I LG320EIK-A5(320W) BUYER:
INVERTER 1 7 PCS.1 ENPHASE I I06PLUS-72-ACM-US
ROOF TYPE I TILE W7 COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD CITY 7 NA NA NA BUYER:
TILT 23- NA° NA° NA'
AZIMUTH 180, NA' NA' NA' DATE:
3' S'-6'
s
Q J
OLL
SOLADECK WIRE
TRANSITION BOX 's
(UNDER ARRAY) 0
PV AC DISCONNECT 1�t m I
EXTERIOR-GARAGE V Q .5 o
UTILITY METER 6LL Z ry
MIN SERVICE PANEL—,--[ Q 4 `o `^
(VERIFIED BY BUILDER)
AC COMBINER BOX W O�
Kob
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 1678 ELEVATION L-L ENH Z
ORIENTATION 2 LOT# 18
ORIGINAL BY:ARTHUR HICKS DATE:18.04.24
HERITAGE HEIGHTS 980 MOLENNAR: REVIEWED BY:DUSTIN LANNING DATE:18.04.24
900 NA.CA 92 DRIVE,#302
CORONA,LA 92879 REV.# BY DATE DESCRIPTION •,
namasb8
60LM
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VLhrLchsster Circle
INDIVIDUAL 20550 WEDELIA STREET Suite 700
PLOT PLAN 1 1/I6'=1'-0" MENIFEE,CA Boulder,CO 80301
SYSTEM LAYOUT
3D3.447.0300
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY I MANUFACTURER MODEL NOTES TRADE
1 7 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE IQ6PLUS-72-ACM-US MICROINVERTER SOLAR
2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV.30A SOLAR
4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR
5 1 ENPHASE X-I0-AMI-240-B AC COMBINER BOX SOLAR
6 1 ENPHASE TBD PV BREAKER. IX 20A-2P,1 X 5A-2P SOLAR
7 1 CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P,RATING MAY VARY SOLAR
B I TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC,
9 1 TBD TBD UTILITY METER,IPH.120/24OV.200A BLDR. ELEC_
10 1 TBD TBD I GROUNDING ELECTRODE.UFER I BLDR. ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS:
MOD, PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 1.17A x 70100S)- B.14A OF CURRENT
MOD. POWER STC(P) AC MODULE SPEC WATTS(o[) 320 8.I9A X 1.25= 10.24A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 2OAl2P 2 SPACE PV BAc8FEE0 BREMER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 24D/211-264
NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741/ IEEE1547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPO AC MODULE SPEC AMPS(AC) 20 '
AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC OTY 7
BRANCH CIRCUIT OUTPUT, IMAXBC (IAC°MOD.aTY 80 AMPS(AC) 8.19
AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 7
TOTAL SYSTEM OUTPUT IMAXTS 0AC'MOD. QTY T) AMPS(AC) 8.19
CONDUCTOR SIZING CALCULATIONS
1)CONDITION OF USE(COU): (AMPACITY'TEMP. DERATE' FILL DERATE)vs.REDID(IMAX)
2)TERMINALS(TERM): I AMPACITY AT TERMINALS. VS. REO'D.(IN"' 1.25)
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP, FILL RESULT REOID OCD
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A #12 CU THWN-2 COU 30 .76 1.0 22.80 8.19
TERM 25 25 10.24 20
B #to CU NM-B CDU 40 .91 1.0 36.40 B.19
TERM 35 35 10.24 20
C #10 CU NM-B COU 40 .91 1.0 36.40 R.IQ
TERM 35 35 10.24 20
CONDUCTOR SCHEDULE
KEY 1CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENPHASE Q CABLE. 1-#6G.FREE AIR CU UL3003.OG CABLE ARRAY ISOLAR
B 1 3-#10-.I-#10 EGG I CU I NM-B(ROMEX) I INTERIOR ISOLAR 9
C 1 3-#10, I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR _
'NEUTRAL CAPPED AND NOT USED M
8
4 3O
O AF O
oaz
IM
G�J
A B C C s 10
I 1 I
1 ROOF 1 EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.240XW
LOT#18
ORIGINAL BY:ARTHUR HICKS I DATE:18.04.24
HERITAGE HEIGHTS LENNAR:
98D MONTECITO DRIVE,#302 REVIEWED BY:DUSTIN LANNING I DATE:18.04.24
CORONA,CA 92879 REV.# BY DATE DESCRIPTION R
namasb6
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Vdnchester CimAe
INDIVIDUAL 28550 WEDELIA STREET Suite 70D
PLOT PLAN 2 NTS MENIFEE.CA Boulder,CO BM01
ELECTRICAL 303.447.0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT,
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH W)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND
THE EDGE OF THE PV ARRAY 7 SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
IN 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING.MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
IS)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
IL)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIRDSTOP TO.BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
])MODULE CERTIFICATIONS WILL INCLUDE U1_1703. IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TD INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING 7 PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT Ill.
10)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:ARTHUR HICKS DATE18.04.24
HERITAGE HEIGHTS LENNAR:
980 I DRIVE, #302 REVIEWED BY:DUSTIN LANNING DATE18.04.24
2
CORONNA,A.C CA A 92879 REV.# BY DATE DESCRIPTION
namaste
DWG TITLE: PAGE#: SCALE: +otne
SITE LOCATION: 6]0]VSuite 7terCilGe
INDIVIDUAL E8550 E.CA A STREET SWIGO8
PLOT PLAN 3 NTS MENIFEE,C4 Boulder,C080301
NOTES 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
SoLADEC%WIRE
TRANSITION BO%
(UNDER ARRAYJ
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER B
MAIN SERVICE PANEL
(VERIFIED BY BUILDERI
AC COMBINER 80%
Z`=fn-
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 8. 19A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:ARTHUR HICKS DATE18.D4.
LENNAR: 24
HERITAGE HEIGHTS REVIEWED BY:DUSTIN LANNING DATE:18.04.24
980 MONTECITO DRIVE,#302
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
namaste
- ti SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Wnchesler Circle
INDIVIDUAL 28550 WEDELIA STREET Su8e 700
PLOT PLAN 4 NTS MENIFEE.CA Boulder,CO 80301
PLACARDS 303.44TO30)