PMT18-03056 City of Menifee Permit No.: PMT18-03066
29714 HAUN RD.
MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE MENIFEE Date Issued: 0 8/0 712 01 8
PERMIT
Site Address: 28592 WEDELIA ST, MENIFEE, CA 92584 Parcel Number: 333-650-007
Construction Cost: $5,613.76
Existing Use: Proposed Use:
Description of SOLAR TR 31582-HERITAGE HEIGHTS
Work: 7 MODULES,7 INVERTERS, 2.24 KW
LOT 16 PLAN 1782
Owner Contractor
LENNAR HOMES OF CALIFORNIA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DRIVE SUITE 302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant License Number.728102
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Phone:9518173539
Fee Description QtV Amount ISI
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICA
TION Aff MENIFEE�
' it lI i12{ a1FET'
DATE: 6/12/2018 PERMIT/PLAN CHECK NUMBER
PLANNING CASE NUMBER
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Heritage Heights Master Permit#- PMT17-00129
Kw: a-, ay PCs: —7 ' y Plan: l� a
PROJECTADDRESS o` 1��/p�., W'n'�.2��I.Q{�s-+ • ZIP 92584
ASSESSOR'S PARCEL NUMBER J '✓$_t� C5O —"Q/ LOT 1140 TRACT 31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO
BUSINESS NAME
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 5613.76 SQ FT L SQ FT I �"
APPLICANT'S SIGNATURE a I DATE V0 I
CITYSTAFF USE ONLY
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
E BUILDING PLANNING GINEERING FIRE
INVOICETOTAL a457\"J'a ,l[� GREEN SMIP
OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777
www.ci tyofm en ifee.us
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.240 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 7 PCS.1 LG LG320EIK-A5(320W) BUYER:
INVERTER 1 7 PCS.1 ENPHASE 106PLUS-72-ACM-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:--
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY ] NA NA NA BUYER:
TILT 23' NA' NA• NA'
AZIMUTH 176' NA- NA- NA' DATE:
Ky
n �A,, oc
Nj 4
Q• &
r� c�R yy�o
(44C cy o•Q�`
SOLADECK WIRE ✓ C j�0 �h� OC' �w
TRANSITION BOX O �Q+�
(UNDER ARRAY) 'B 15 Q
Q
PV AC DISCONNECT
EXTERIOR-GARAGE •`(" aC
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER) w
AC COMBINER BOX
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 1782 ELEVATION B-L ENH Z
ORIENTATION 2 LOT#I6
HERITAGE HEIGHTS LENNAR: ORIGINAL BY:ARTHUR HICKS DATE:I8.04.24
980 MONTECITO DRIVE.#302 REVIEWED BY:DUSTIN LANNING DATE:18.04.24
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namasns
DWG TITLE: PAGE#: SCALE: +o�•v
SITE LOCATION: 6707 VinrJteter Circle
INDIVIDUAL 28592 WEDELIA STREET Suite 70D
PLOT PLAN I/16'=I'-0" MENIFEE,CA Boulder,CO 80301
SYSTEM LAYOUT 3034470300
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE
1 7 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE IQ6PLUS-72-ACM-US MICROINVERTER SOLAR
2 1 RSTC l SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,246V,30A SOLAR
4 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR
5 1 ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR
6 1 ENPHASE TBD PV BREAKER, IX 20A-2P.I X 5A-2P SOLAR
7 1 CUTLER-HAMMER TBD PV BREAKER, I X ZOA-2P,RATING MAY VARY SOLAR
8 I TBD TBD SERVICE PANEL.200A BUS BLDR. ELEC.
9 1 TBD TBD UTILITY METER,[PH, 120/24OV.2DOA BLDR. ELEC.
10 I TBD TBD GROUNDING ELECTRODE,UFER BLDR. ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALL UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE,CA PANEL MFR. I CUTLER-HAMMER
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP.MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40
TEMP,DELTA LOW(TOELTA) THIN-TTEST 'C -27 PV OCPD DEVICE USED AMPS 1 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS:
MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5 WOW) 1.17A X 7(MCDS)= 6.19A OF CURRENT
MOD.POWER STC(P) AC MODULE SPEC WATTS(DU 320 8.19A x 1.25= 10.2LA
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 29D TIE-IN WITH A 2DAI2P 2 SPACE PV BACKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 '
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741I IEEE1547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC QTY 7
BRANCH CIRCUIT OUTPUT, IMAXBC (IAC'MOO.OTY BC) AMPS(AC) 8.19
AC MODULE QUANTITY,TOTAL MOD. QTY T QTY 7
TOTAL SYSTEM OUTPUT IMAXTS QAC'MOD.QTY T) AMPS(AC) 8.19
CONDUCTOR SIZING CALCULATIONS
0 CONDITION OF USE(COU): (AMPACITY - TEMP.DERATE - FILL DEBATE)vs. REO'D(IMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REQ'D.(IMAX' 1.25)
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/D TEMP. FILL RESULT REO'D OLD
TYPE DERATES DEBATE DERATE (A) (A) USED(A)
A Z#12CUUTHWN-2 COU 30 =.761...O22.80 8.19
TERM 2525 10.24 20
B NM-B CDU 40 36.40 8.19
TERM 3535 10.24 20C NM-B COU 40 36.40 8.19
TERM 3535 10.24 20
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS CU7AL TYPE LOCATION TRADE
A -#12 ENPHASE Q CABLE,1-#bG,FREE AIR CU UL3003.DG CABLE ARRAY SOLAR
B 1 3-#10•.I-#10 EGL I CU I NM-B(ROMEX) I INTERIOR I SOLA;___
9
C 3-#10, 1-#10 EGG CU NM-B(ROMEX) INTERIOR SOLA _
'NEUTRAL CAPPED AND NOT USED M
0
IB
4 mLIOA2N� GI
A B L C aQ
I I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.24OKW
LOT#16
ORIGINAL BY:ARTHUR HICKS I DATE:IB.04.24
HERITAGE HEIGHTS LENNAR: REVIEWED BY:DUSTIN LANNING DATE:18.04.24
CORONNA.A.CA 980 I2 DRIVE.#302
92879 REV.# BY DATE I DESCRIPTION
Vnamast;6
tour
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Vdncheeter CimAe
INDIVIDUAL 28592 WEDELIA STREET Su8e 7DO
PLOT PLAN 2 NTS MENIFEE,CA Boulder,CO WW1
ELECTRICAL 303.447.0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE,
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND
THE EDGE OF THE PV ARRAY 7 SUB-ARRAY.
B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40%
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
ID 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD,
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SMALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250,122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
IA)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING 7 PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER,
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:ARTHUR HICKS DATEIB.06.2L
HERITAGE HEIGHTS LENNAR: REVIEWED BY:DUSTIN LANNING I DATEIB.O4.2L
980 MONTECITO DRIVE.#3D2
CORONA.CA 92879 REV.# BY DATE DESCRIPTION 29
namastB
roue
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 WnWesWrCirtle
INDIVIDUAL 28592 WEDELIA STREET SuBe 700
PLOT PLAN 3 NTS MENIFEE,CA BoWBer,CO 80301
NOTES M,"7.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
SOLUDECK WIRE
TRANSITION BOX
MJDER ARRAY)
W AC DISCONNECT
EXTERIOR-GARAGE
UTRITT METER 8
MIN SERVICE PANEL
(VERIFIED By BUILDER)
AC COMBINER BDX
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 8. 19A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:ARTHUR HICKS IbATEJ8.04.24
LENNAR:
HERITAGE HEIGHTS REVIEWEDBY:DUSTIN LANNING DATE18.04.24
98D MONTECITO DRIVE,#302
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
namasCB
SOLA[
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Vdntliester Circle
INDIVIDUAL 28592 WEDELIA STREET Suite7CO
PLOT PLAN 4 NTS MENIFEE,CA Bodder,CO 00301
PLACARDS 303.447.03DO