Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-03050
City of Menifee Permit No.: PMT18-03050 29714 HAUN RD. T Residential Electrical MENIFEE, CA 92586 yam' MENIFEE MENIFEE Date Issued: 07/09/2018 PERMIT Site Address: 29198 REDWOOD ST, MENIFEE, CA Parcel Number: 333-650-013 92584 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582-HERITAGE HEIGHTS Work: 8 MODULES,8 INVERTERS,2.56 KW LOT 22 PLAN 2131 Owner Contractor LENNAR HOMES OF CALIFORNIA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE SUITE 302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant License Number: 728102 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Phone: 9518173539 Fee Description Qy Amount l5l Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Permt Template.rpt Page 1 of 1 BUILDING S ETY PERMIT/PLAN CHECK,APPLICATION. _ NIE NWEEE.J- DATE: 6/12/2018 PERMIT/PLAN CHECK NUMBER ( NI - 50 PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Heritage Heights Master Permit#-PMT17-00129 Kw: ^�1 L .,5(p PCs: b Plan: at 3 ' y PROJELTADDRESS q l J p )VedAl,/ ::Vd ZIP 92584 ASSESSOR'S PARCEL NUMBER �35 ' 01_,'�) LOT 9a TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California, Inc, ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California Inc. OWNER BUILDER? O YES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 5613.76 oSQ�FT L So FT APPLICANT'S SIGNATURE i �JyG� DATE 131 ( 0 CITYSTAFF USE ONLY DEPARTMENTDIST RIB UTON ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICETOTALol��J ,�1 GREEN SMIP OWNER BUILDER VERIFIED OYES OKNO DRIVERS LICENSE# NOTARIZED LETTER XYES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586(951)672-6777 www.cityofmenifee.us N' SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM QTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE .56DKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 2 8 PCS.1 LG I LG320EIK-AS(320W) BUYER: INVERTER 1 8 PCS.I ENPHASE I 106PLUS-72-ACM-US --- ROOF TYPE I TILE W7 COMPOSITE SHINGLE UNDER ARRAY DATE: _ SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 MOD QTY 8 NA NA NA BUYER: ZIMUTH 1 270' 1 NA' NA' NA' DATE: y�gu� 5 fi 3 fY•_ � N iYyJ �.I p A F- Z O m O W C W T 0 2 pN ` > q I pdg SOL A WIRE TRANSITION w TRANSITISITI ON BO% K\1 (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE ' UTILITY METER MAIN SERVICE PANEL (VERIFIED BY BUILDER) -� AC COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 2131 ELEVATION C ENH-LEFT ORIENTATION I LOT#22 ORIGINAL BY:CHRISTINE MARTINI DATE:I8.OL.19 HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:ANGLEA BURKE DATE:18.04.20 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namaste DWG TITLE: PAGE#: SCALE: ricuc SITE LOCATION: 4871&o,GO BStreet INDIVIDUAL 29198 REDWOOD STREET 8o03a4 PLOT PLAN 303. 703 I/16'= I'-D' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES TRADE I 8 I LG LG3ZOEIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 I 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221LJRB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 4 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 I ENPHASE X-I(I-AMI-24O-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 2OA-2P,I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P,RATING MAY VARY SOLAR B 1 TBD TBD SERVICE PANEL,ZOOA BUS BLDR. ELEC. 9 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR. ELEC, IO 1 TBD TBD GROUNDING ELECTRODE,UFER I BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS ZOO TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP.DELTA LOW(TEELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) I.I7A x B(MODS)= 9.36A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 9.36A x 1.25= u.7D4 PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN wITH A 20A/2P 2 SPACE PV BACNFEED BREAXER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AU 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/ IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY Be CITY 8 BRANCH CIRCUIT OUTPUT, IMAXBC (IAC°MOD.QTY Be) AMPS(AC) 9.36 AC MODULE QUANTITY,TOTAL MOD. DTY T QTY B TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD. QTY T) AMPS(AC) 9.36 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COL): (AMPACITY• TEMP.DERATE ° FILL DERATE)VS.REQ'D(IMAX) 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.VS. REQ'D,(IMAX- 1.25) KEY SIZE CU/AL I INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OLD TYPE DERATES DERATE DERATE (A) (A) USED W A #12 CU I THWN-2 30 .76 I.0 22.80 9.36 COU TERM 32 25 11.70 20 B #10 CU NM-B COU 40 .91 1.0 36.40 9.36 TERM 35 35 11.70 20 L #10 CU I NM-B COU 40 .91 1.0 36.40 9.36 TERM 35 135 11.70 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENPHASE 0 CABLE.1-#6G,FREE AIR I CU I UL3003,DO CABLE I ARRAY I SOLAR 8 3-#10•.I-#ID ESL I CU I NM-0(ROMEX) I INTERIOR I SOLAR 9 C 3410, 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR _ 'NEUTRAL CAPPED AND NOT USED O O I B 5 4 e O AIPP O O © LOa 'A" 'N G zo ' G GJ RDOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.56OKW LOT#22 ORIGINAL BY:CHRISTINE MARTINI DATE:18.04.19 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ANGLEA BURKE DATE:18.04.20 CORONNA,A.C CA 980 DRIVE,#302 REV.# BY DATE DESCRIPTION A 92879 namasGib DWG TITLE: PAGE#: SCALE: SITE LOCATION: soiAq INDIVIDUAL 29198 REDWOOD STREET 4577 Broadway Street PLOT PLAN 2 NTS BDNde00004 ELECTRICAL MENIFEE,CA 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(J•)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE, PEEL-WSTICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC7CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A.90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)QC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:CHRISTINE MARTINI DATE18.0 LENNAR: 4.19 HERITAGE HEIGHTS REVIEWED BY:ANGLEA BURKE DATE18.04.20 980 MONTECITO DRIVE,#307 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, namasr6 $ON. DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway CO Street PLOT PLAN 3 NTS MENI REDWOOD STREET Boulder, 7. 8000d NOTES MENIFEE,CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SO ADECN WME TRANSITION BO% (TINDER MR44 Iry AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BD% SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.36A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI DATE18.D4.19 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ANGLEA BURKE I DATE18.04.20 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamasr6 SOLAR DWG TITLE: 74Nl treet ALE: SITE LOCATION: INDIVIDUAL 4571 Boulder, COa8 304 PLOT PLAN S 29198 REDWOOD STREET BDultler,C 80304 PLACARDS MENIFEE.CA 303.447.0300