Loading...
PMT18-03049 City of Menifee Permit No.: PMT18-03049 29714 HAUN RD. Type: Residential Electrical y MENIFEE,CA 92586 MENIFEE MENIFEE Date Issued: 07/09/2018 PERMIT Site Address: 29212 REDWOOD ST, MENIFEE, CA Parcel Number: 333-650-012 92584 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582-HERITAGE HEIGHTS Work: 10 MODULES, 10INVERTERS,3.20 KW LOT 21 PLAN 2686 Owner Contractor LENNAR HOMES OF CALIFORNIA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE SUITE 302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant License Number:728102 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Phone:9518173539 Fee Description Qtv Amount lSl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Penmft_Template.rpt Page 1 of 1 BUILDING &SAFETYPERMIT/PLAN CHECK APPLICATION MENIFEE DATE: 6/12/2018 PERMIT/PLAN CHECK NUMBER Amb jn0q11 PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OFSQUARES DESCRIPTION OF WORKK� Solar Permit-Heritage Heights Master Permit#-PMT17-00129 Kw: tl• P-�D PCs: (0 Plan:/ PROJECTADDRESS a'I�' .errjtf4%olN S-1--- r1 ZIP 92584 ASSESSOR'S PARCEL NUMBER V t OLCJT o" TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANTNAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES O NO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 5613.76 SQ FT L SQ FT c APPLICANT'S SIGNATURE am-01�� DATE CO/13I/6 CITYSTAFF USE ONLY -4LEbL— DEPARTMENT DISFRIBDTION ACCEPTED BY' ffi CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL (�3- .(„a GREEN SMIP OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee,CA 92586 (951)672-6777 www.cityofinen ifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3,2OONW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE IO PCS.1 LG I LG32OEIK-A5(32OW) BUYER: INVERTER IO PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE TILE W/COMPOSITES SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 10 NA NA NA BUYER: TILT A NA° AN NA° AZIMUTH 1 139° NA' I NA* NA° DATE: fill ts • 9 PA2 a5 T LASZ Z O m Q W N O T'J a t9 a w Z _ _ S ADECK WIRE U. p �+ � TRANSITION BOX 9 o (UNDER ARRAY) ez( W a o m CL Ix 1 PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 9 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION A ENH-RIGHT �® ORIENTATION 2 LOT#21 ORIGINAL BY:CHRISTINE MARTINI DATE:IB.0L.19 HERITAGE HEIGHTS LENNAR: 980 MONTELITO DRIVE,#302 REVIEWED BY:ANGLEA BURKE DATE:IB.0L.2O CORONA,CA 92879 REV.# BY DATE DESCRIPTION co namasbi§ DWG TITLE: PAGE#: I SCALE: aoua SITE LOCATION: 4Bo Broadway 304 INDIVIDUAL MENI REDWOOD STREET Boulder,CO 80304 PLOT PLAN I I/16'=1'-0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 10 LG LG320EIK-A5 MOW) ACPV MODULE W/ INTEGRATED ENPHASE IQ6PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V,30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBO PV BREAKER, I X 20A-2P.I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P.RATING MAY VARY SOLAR 8 I TBD TBD SERVICE PANEL.200A BUS BLDR. ELEC. 9 1 TBO TBD UTILITY METER, IPH, 1201240V,200A BLDR. ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS ZOO TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS LO TEMP.DELTA LOW(TEELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(32OW) 1.17A x D MODS)• 11.7DA OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 I1.70A x 1.25. 14.63A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20AIV 2 SPACE PV BACRFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/ IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE DUANTITY.MAX PER BRANCH CIRCUIT MOD. OTY BC QTY 10 BRANCH CIRCUIT OUTPUT,IMAXBC OAC°MOI BC) AMPS(AC) 11.70 AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 10 TOTAL SYSTEM OUTPUT IMAxTS OAC•MOD.QTY T) AMPS(AC) 11.70 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COU): I(AMPACITY ° TEMP.DEBATE• FILL DEBATE)vs.READ OMAX) 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.y .. REQ'D,(IMAx` 1.25) KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REOT OCD TYPE DEBATES DERATE DEBATE (A) W USED(A) A #12 CU I THWN-2 COU 30 .76 I.D 22.80 11.70 TERM 25 25 14.63 20 B #ID CU NM-B COU I 4D .91 1.0 36.40 11.70 TERM 35 35 14.63 20 C #10 CU NM-B COU 40 .91 1.0 36.40 11.70 TERM 1 35 35 14.63 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL TYPE 1 LOCATION 1 TRADE p I I-#12 ENPHASE Q CABLE.I-#6G,FREE AIR I CU UL30D3,DG CABLE IARRAY I SOLAR B I3-#10•.1-#10 EGC CU I NMI(ROMEX) I INTERIOR I SOLAR 9 L 1 3410, 1410 EGC CU NM-B(ROMEX) I INTERIOR I SOLAR _ 'NEUTRAL CAPPED AND NOT USED M O I 0 4 03 O5A/A 7 I O © La2o 2012 L G G� ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.20OKW LOT#21 ORIGINAL BY:CHRISTINE MARTINI DATE:I8.OL.I9 HERITAGE HEIGHTS LENNAR: 960 MONTECITO DRIVE,#302 REVIEWED BY:ANGLEA BURKE I DATE:18.04.20 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Pniamast;6 so'Xv DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4B7R&o,DO Street PLOT PLAN 2 NTS MENI REDWOOD STREET Boulder,CO80804 ELECTRICAL MENIFEE,CA 308.A47.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48`O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED, 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(1')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE, COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC6173D. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. III)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:CHRISTINE MARTINI DATEIS.D4.19 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ANGLEA BURKE DATEIB.04.2D 980 MONTECITO DRIVE.#3D2 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, namasb6 COLA. DWG TITLE: PAGE#: SCALE: SITE LOCATION: treet INDIVIDUAL E571 Broadway CO5 3M PLOT PLAN 3 NITS 2ENI RE.CA STREET Boulder.303. CO80304 NOTES MENIFEE.CA 303.dd7.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOIADECK WIRE TRANSITION BOY. (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MIN SERVICE PANEL (VERIFIED BY BUILOER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI I DATEJB.04.19 LENNAR: HERITAGE HEIGHTS REVIEWED BY:ANGLEA BURKE DATEJB.04.20 980 MONTECITO DRIVE,#302 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namast6 roue DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Braadway Sheet INDIVIDUAL 29212 REDWOOD STREET Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS