PMT18-02348 City of Menifee Permit No.: PMT18-02348
29714 HAUN RD. Type: Residential Addition
<�CCELX_> MENIFEE,CA 92586 YP
MENIFEE Date Issued: 05114/2018
PERMIT
Site Address: 31585 NORTHFIELD LN,MENIFEE,CA Parcel Number: 358-231-004
92584 Construction Cost: $12,500.00
Existing Use: 1 &2 Family Residence Proposed Use:
Description of AS-BUILT RETAINING WALL PER CITY STANDARD
Work: 4'X 369 L FT
Owner Contractor
RICHARD AND CORINNE QUESADA
31585 NORTHFIELD LN
MENIFEE, CA 92584
Applicant License Number:
RICHARD AND CORINNE QUESADA
31585 NORTHFIELD LN
MENIFEE, CA 92584
Phone:9516724310
Fee Description QYt Amount!$1
Building Permit Issuance 1 27.00
Wall/Fence, standard 1 83.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Building 1 4.15
$117.15
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA Bldg_Pemiit_Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and I am exempt from licensure under the Contractor's State License Law for
Professions Code and my license is in full force and effect. the following reason: pt.jnew'z
License Class License No. By my signature below I acknowledge that,except for my personal residence
Expires Signature in which I must have resided for at least one year prior to completion of
WORKER'S COMPENSATION DECLARATION improvements covered by this permit.I cannot legally sell a structure that I
have built as an owner-builder if it has not been constructed in its entirety by
❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Cade,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Cade,for the performance of work for which
this permit is issued. V.a o.ca ov calaw.h
Policy M Date
o 1 have and will maintain worker's compensation insurance,as required by PROPERTY OWNER OR AU ORIZED AGENT
section 3700 of the Labor Code,for the performance of the work for which By my signature below I certify to each of the following:I am the property
this permit is Issued.My worker's compensation insurance carrier and polity owner or authorized to act on the property owner's behalf.I have read this
number are: application and the information I have provided is correct.I agree to comply
Carrier with all applicable city and county ordinances and state laws relating to
building construction.I authorize representatives of this city or county to
Policy fJ Expires /erRert a above identified pro rty for inspection purposes.
(This section need not to be completed is the permit is for one-hundred
dollars($100)or less Y
PROPERTY OWNER OR AUTHORIZED AGENT Date
❑1 certify that in the performance of the work for which this permit is issued,
I shall not emolov any persons in any manner so as to became subject to the CITY BUSINESS LICENSE k
worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the worker's compensation provisions of Section 3700 of the Labor
Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a
Applicant Date mixture containing a hazardous material equal to orgreaterthat the
amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ❑No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES
AND CIVIL FINES UPTO ONE HUNDRED THOUSAND DOLLARS($100,000),IN Will the intended use ofthe building the applicant arfuture building
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR occupant require a permit for the construction
ruction modification from South
IN SECTION 3706OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES Coast Air quality Management District(SCADM D)D)?See permitting checklist.
for guidelines
CONSTRUCTION LENDING AGENCY ❑Yes DNo
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is issued outer boundary of a school?
(Section 3097 Civil Code) ❑Yes ❑No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAOMD
I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of
Contractors License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25505 and 25534 concerning
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 hazardous material reporting.
Business and Professions Code).Any city or county that requires a permit to oyes D Na
Date
construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT
issuance,also requires the applicant for the permit to file a signed statement
that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING IRRPI
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from Iicensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more
tha 500). required practices.This includes rental property owners and property
managers who do the paint-disturbing work themselves or through their
1,as owner of the property,or my employee with wages as their sole employees.For more Information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractors State License Law does not apply to an owner of a D An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because:
D I,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE
DATE: S/1�+ ( PERMIT/PLAN CHECK NUMBER T( 6-0c?348
PLANNING CASE NUMBER
TYPE: OCOMMERCIAL ARESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION CO DEMOLITION O ELECTRICAL O MECHANICAL
NEW O PLUMBING 0 RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORKQ[--Pc�.
PROJECTADDRESS ?j� ,JpS �Q'Q,kV�'�[A't'eII,G\ LAN C ZIP 9 21!�gl'Il
ASSESSOR'S PARCEL NUMBER LOT N TRACT 2R43
OWNER NAME G hG__ \\
ADDRESS G��✓ SgS Iv0 `G�C% G KCn: /
PHONE EMAIL Lke5A�>Pt
APPLICANT NAME '5.0^C
ADDRESS
PHONE EMAIL
CONTRACTOR'S NAME OWNER BUILDER? YES ONO
BUSINESS NAME
ADDRESS
PHONE EMAIL
CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION
VALUATION$ 1; 600 SQ FT L SO FT /
APPLICANT'S SIGNATURE DATE
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION ACCEPTED CITV OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE
INVOICETOTAL , I GREEN r'-' SMIP
OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6a77
www.cityofinenifee.us
TYPE 1: 6" TOE �D�SSeo?Z TYPE 2: 6" HEEL
171- I �`=O1yP•OF IEVEL GRADE 1 \\ SGIF LEVEL GRADE
1�= SEE TABLE FOR LEVEL GRADE j SEE VEL GRADE
=� CITY OF MENIFEE =�=R
#4 HORD.ATTOP COARSE #4 HORR ATTOP COUR E
BUILDING AND SAFETY E E RTMEI
#4 HORI20NiPLREBAR qT 24"ONCE PLAN APPROVAL
#4H AT24"ONC NTEN
Y-BARS ! REVIEWED BY �K
"H" i B"CONCRETEBLOCK
6.-O.w. ' ,�y�\tTTFF
2-3/4"M1lAATcF^H TO SCALE)
2-3/4,,n1AX
#4 HORIZ AT 24"ON CENTER �#AppAY✓t_ICtl}}le6@pIIM N�I(aj�I�/Iw IM C066 5 �1GR2ATTe"ON
appro"I A any tNMWn N a..l , IAI�j131 MAX U�''AI'
3"MgX Ipl wmq and GPdYuMK Tw I ofavid
�Im "H1" lobuh uo eompq m i 6" "H1"
12 BLOC ORNNAGE ST
DRAINAGE 6T5. I (i2"BLOCK)
-SEE NOTE5 '•F• 'Sf£NOTES
FINISH FINISH
GRADE 1'11 ,• 1111=_1111=_ GRAGE T IITI�
)III WI WIpR WI_GG
16"min _ II11 111' 16"min XBAR6
12" I 12"
7rBARS
X-BARS (3)-#4
Z-BARS W. HGRIZONTu (2)-#4 "K"
6" PEBgRS HORIZONTAL
RS
PEZO
W.
TYPE 1: 6" TOE
GRADE "H" "H1" "W" X BARS Y BARS ZBARS "K"
CONDITION (WALL HEIGHT) (12"BLOCK) (FOOTING WIDTH) (KEY DEPTH)
5'-1"to 6'-D" 24" 69" #4 @ 16" 04 @ 32" 04 It- 30"
SLOPING GRADE 4•-1-to 5'-0" NIR 48" #4@16" 04 16" 94 12" 25"
AT TOP OF WALL 3'-1"to 4'-0" NIR 30" #4 @ 32" #4 @ 32" #4 Q 32" 16"
(2:1 MAX) Up to 3'.0" NIR 18" 04 @ 32" 04 @ 32" #6 LZ 32" 8"
5'-1"to 6'.0" 24" 45" #4 @ 24" #4 32" 94 @ 24" 8"
LEVEL GRADE 4'-1"to 5'.0" NIR 36" 44 @ 24" #4 24" #4 @ 24" 1"
AT TOP OF WALL 3'-1"to 4'-0" NIR 24" #4 32" #d ]2" p4 32" 5"
NIR
TYPE 2: 6" HEEL
GRADE "H" "H1" "W" X BARS Y BARS ZBARS "K"
CONDITION (WALL HEIGHT) (12"BLOCK) (FOOTING WIDTH). (KEY DEPTH)
5'-1"to 6'-0" 24" 39" #4 Q 16" #4 @ 32" #4 @ 12" 28'•
SLOPING GRADE 4•-1••to 5'-0" NIR 29" #4 @ 16" #4 @ 16" 94 @ 12" 12" 06
AT TOP OF WALL 3'-1"to 4'.0" NIR 24" #4 @ 32" #4 32" #4 @ 32" 15" O
(2:1 MAXI Up to 3'.0" NIR Ill.- It"#4 @ 32" 04 32" #4 @ 32" "
5'-1"to 61-0" 24" 33" #4 @ 24" #4 @ 32" #d @ 24" 18"
LEVEL GRADE 4'-1"lo 5'-0" NIR 26" #4 24" #4 24" 94@24" 13" 1
AT TOP OF WALL 3'-1"to 4'-0" NIR 30 #4 @ 32" 24 32" #4 @ 32" T" ,1
Up to 3'-0" NIR 20" #4 32" #4 32" #4 1W�
NIR = NOT REQUIRED _
'SEE PAGE 2 FOR ADDITIONAL INFORMATION' WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM
f Menifee CITY of MENIFEE
DISCLAIMER: Cif ALTERNATE RETAINING WALL DESIGNS MAY NIp UIIling NY"ILDING DEPARTMENT
BE POSSIBLE WHEN PROVIDED WITH AN
ENGINEERED ANALYSIS. USE OF THIS M 4 2018RFTAINING WALLS
STANDARD DESIGN IS AT THE USER'S RISK
AND CARRIES NO IMPLIED OR INFERRED 4951)672677 29714 (v ROAD,MENIFEE,CA 92586
GUARANTEE AGAINST FAILURE OR DEFECTS.
FAX(951)67 843 '2Di .CITYOFMENIFEE.US PAGEIOF2
GENERAL NOTES:
1)ALL WORK SHALL CONFORM TO THE ADOPTED CODES AND ZONING REGULATIONS.
2)CONCRETE BLOCK MASONRY SHAI C_C�MPI Y�^V1.T.H.S OLLOWING:
B. MORTAR:TYPE M OR S SHALL CON'1 ,GRADE-N.
C. GROUTALLCELLSW aDiffi Peakky�DlD.IG) YM4€!J OUT.
.�•N" j C 1 °IBC UY1A UYf,IJ ,
3)THEULTIMATE COMPRESSIVE STREIVG�Ffj.R jFgR OUNDATION CONCRETE SHALL BE 2500 PSI.
4)ALL REI O SH JJAA EDIATE GRAD ASTM A61 5-40 AND OVERLAP SPLICES SHALL
BE 40`�'1yQ��'�s1 I E nRHOOKSSH LBEA MINIMUM OF 12TIMESTHEREBAR
DIAtv1E M ) I ENGTT Y3 MS
5) PROVIDE RETAINING WALL DRAINAGE SYSTEM AS FOLLO S:
PROVIDE 1 CF/FT OF CLEAN COARS GR VELNITH DI METER PERFORATED PVC DRAINAGE PIPE WITH
1%GRADIENT TO?gIAAl14 ��tI�N�I E�/�1 � 71`�I 1 FIRST OURSE.
z 1a1�i 91 ed1?u znoieivolq ills to no9skiv tr£,io i;volggs
6)OPTIONAL:INST% �I�Q Qf,�l ,�t36+"FI I�fiiltfppdtT FILL SIDE OF THE WALL WILL HELP TO
PREVENT MOIST(JR2 OM NETRATIN Y ,�yh5j*,Ep)pIl E OF THE WALL, RESULTING IN
DISCOLORATION.
7)THIS RETAINING WALL STANDARD IS NOT DESIGNED TO SUPPORT SURCHARGE LOADS FROM MOTOR
-- VEHICLES OR OTHER STRUCTURES.
B) CLEANOUTS SHALL BE PROVIDED FOR ALL GROUT POURS OVER 5 FEET IN HEIGHT. WHERE REQUIRED,
CLEANOUTS SHALL BE PROVIDED IN THE BOTTOM COURSE AT EVERY VERTICAL BAR AND SHALL BE
SEALED AFTER INSPECTION AND BEFORE GROUTING.
REQUIRED INSPECTIONS:
1) FOOTING;
EXCAVATION TRENCH CLEAN WITH STEEL IN PLACE AND SUPPORTED 3"ABOVE AND AWAY FROM THE
SURROUNDING EARTH/DIRT.
2) REBAR/PRE-GROUT ANo DRAINAGE SYSTEM;
- --BOND cBEAM-REBAR-AND-VERTICAL REBAR-IN-PLACE--INSPECTION-PRIOR TO-PLACING-GROUT:- - -
DRAINAGE SYSTEM COMPLETE.
3) FINAL;
AFTER GROUT IS PLACED AND BACKFILL COMPLETED-PRIOR TO ANY DECORATIVE CAP PLACEMENT.
SETBACK FROM TOP OF SLOPE: DESIGN PARAMETERS:
ALL FOOTINGS ADJACENT TO SLOPESTO BEAT ACTIVE SOIL PRESSURE(PSF)
LEAST 5'To DAYLIGHT AS SHOWN BELOW. LEVEL BACKFILL = 30
IIIIIILL_ SLOPING(2:1 MAX) =43
• 0% PASSIVE SOIL BEARING(PSF) =150
9 COEFFICIENT OF FRICTION =0.25
00III-jI ALLOWABLE SOIL BEARING PRESSURE(PSF) =1500
IW-IW-: /2;1 MAX SLOPE (NO INCREASES TAKEN FOR DEPTH OR WIDTH OF FOOTING)
rillnIIII :• 11J 6=JII Q
h ' _ _ 5' MIN. 9<�
BOTTOM
OF FOOTING
WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM
c^aF CITY OF MENIFEE
DISCLAIMER: <. BUILDING DEPARTMENT
ALTERNATE RETAINING WALL DESIGNS MAY MENIFEE
BE POSSIBLE WHEN PROVIDED WITH AN -- -
ENGINEERED ANALYSIS. USE OF THIS �x / RETAINING WALLS
STANDARD DESIGN IS AT THE USER'S RISK "
AND CARRIES NO IMPLIED OR INFERRED
GUARANTEE AGAINST FAILURE OR DEFECTS. (951)672.6777 29714 HAUN ROAD,MENIFEE,CA 92586
FAX(951)679-3843 2/2A/2014 I WWW.CITYOFMENIFEE.US I PAGE20F2
PLOTISITE PLAN N
REAR PROPERTY LINE
AMM
1
N �
City of Menifee
Building Dept. de
MAY 1 4 2018
Received W
Lim.
W i
tax W
z
00 a.
O
a a
a �
N
l
CITY OF MENIFEE
BUILDING AND SAFETY DEPARTMENT
PLAN APPROVAL
REVIEWED BY PX0000 O
Do
'Approval of these plans shall not be construed to be a permit for,oran
appro,al of,any violation of any provisions of the federal,state or city
regulations and ordinances. This set of approved plans must be kept on the
jobsite until completion.
o '
FRONT PROPERTY LINE
Property Owners Name R,()naga ADD Cr](Z�(1f1P_ �AFS42rhA
Property Address 31555 h1f)2A 61A W JG l!MMCCr LA 5'Z �