PMT18-02192 City of Menifee Permit No.: PMT18-02192 29714 HAUN RD. Type: Residential Mechanical <ACCF=L:J MENIFEE, CA 92586 MENIFEE Date Issued: 05/04/2018 PERMIT Site Address: 25810 INTERLECHEN DR, MENIFEE, CA Parcel Number: 339-123-017 92586 Construction Cost: $7,521.00 Existing Use: Proposed Use: Description of REMOVE AND REPLACE 3 TON/80,000 BTU COMPLETE HVAC SYSTEM Work: Owner Contractor THOMAS WEST W C HEATING&AIR CONDITIONING INC 258101NTERLECHEN DRIVE 41085 GOLDEN GATE CIR MENIFEE, CA 92586 MURRIETA, CA 92562 Applicant Phone:9516000700 W C HEATING&AIR CONDITIONING INC License Number:779604 41085 GOLDEN GATE CIR MURRIETA, CA 92562 Phone:9516000700 Fee Description Oty Amount(S) Forced-Air or Gravity-Type Furnace or Burner 1 149.00 Air Handling/Condensing Units SFR 1 133.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 General Plan Maintenance Fee-Mechanical 1 14.10 $324.10 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of ally of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE DATE: g PERMIT/PLAN CHECK NUMBER - O PLANNING CASE NUMBER TYPE: 0 COMMERCIAL a4ESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA 0 SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK 7LIGIC z ,3}Ova g0 LOCO 1 V Comiale-A-e C. S44exn PROIECTADDRESS ZSssIC) 1;,4,rl clneh b2r ZIP q25� ASSESSOR'S PARCEL NUMBER ' ' L�.� LOT TRACT OWNER NAME ) g ADDRESS ZS Slp L� -.e..� �r �,-� C'', CA q,ZS PHONE 20S-sg7.ZNIJ EMAIL APPLICANT NAME �11nLe ADDRESS 3i2zS La 5�a Dt #'213 1 s�� t�i��a c CA 913b2 PHONE $18-73,5--727` EMAIL CONTRACTOR'S NAME L)a Care_ OWNER BUILDER? O YES O BUSINESS NAME ADDRESS Z4tDeS o�dcr aAc_C.C- v i k ClZS�_-2- PHONE t!$)-fefX>-O'10D EMAIL CONTRACTOR'S STATE LIC NUMBER 7-7�IcD� LICENSE CLASSIFICATION C10 VALUATION$ 7,SZ-I,LU SO FT L SQ FT APPLICANT'S SIGNATURE n....7 �y DATE °I- 12 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENG/ EERING FIRE INVOICETOTAL �al, , '0 GREEN SMIP OWNER BUILDER VERIFIED O YES 0 NO DRIVERS LICENSE# NOTARIZED LETTER C YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee,CA 92586(951)672-6777 www.cityofmenifee.us City of Menifee NIF Building Dept, MAY 0 4 2018 Pdara®iv®ri STATE OF CALIFORNIA ALTERATIONS - HVAC CEC-CFIR-ALT-04-E Revised 01/16 CALIFORNIA ENERGY COMMISSION It CERTIFICATE OF COMPLIANCE CFIR-ALT-04-E Alterations-HVAC CZ 2,and 8-15 (Page 1 of 1) Site Address: Enforcement Agency: Dat Pepared: Permit#: 25$10 �.��r�echel. �r % OF nr-,- tee 5 w 18 Equipment T e E ui ment Effcien New ucting or Uneset: Conditioned YP q P cY Required R-value Floor Area(ft,) Thermostat ❑Packaged XEvaporator Coil �.l COP ' 0 R-6 (CZI-10,12&13)Ducts Served by system ]Setback System Condensing Unit z (If not already IffSplit System ❑Compressor SEER HSPF ❑R-8t (CZ 11,14-16)Ducts 02l ft ❑2 R-2.8 Lineset` present,must ❑Mini Split ❑Uneset EER be installed) 0 Furnace ❑TXV HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand. For final inspection all forms are to be registered(no hand filled forms allowed)and a copy left on site. 1.HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: All Equipment, CF1R-ALT-02-E Condenser Unit,Evaporator Coil, CF2R-MCH-01-E,MCH-20-H,MCH-(23 or 24)a-H,MCH-25-H3 Compressor,TXV,Lineset, CF3R-MCH-20-H,MCH-(23 or 24)-H3,MCH-25-H2 Air Handler/Fumace2(Can include new ducting) Installer Requirement:Duct leakage(s 15%,or 510%to outside,or seal all accessible leaks),Air Flow 2 300 CFM/ton,Refrigerant Charge. Exempted from duct leakage testing if: ❑1.Duct system registered with HERS provider as previously sealed,or 0 2.There is less than 40 linear feet of duct in unconditioned space,or ❑3.Existing duct systems are constructed,insulated or sealed with asbestos(list manufacture date of building ❑2.New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts3 CFIR-ALT-02-E including Mini Split CF2R-MCH-01-E,MCH-20-H,MCH-22-H,MCH-(23 or 24)-H3,MCH-25-H2 CF3R-MCH-20-H,MCH-22-H,MCH-(23 or 24)-Hz,MCH-25-Ha Mini Splits require CFIR-ALT-02-E,CF2R-MCH-01-E,and(CF2R-CF3R)MCH-25-H Installer Requirement:Duct leakage<5%,Fan Efficacy(0.58W/CFM),Air Flow 2 350 CFM/ton(or alternative),Refrigerant Charge ❑3.All New Ducts with Replacement Required Compliance Documents to be left on site for Final: City of Mwifee All New Ducts3 and one or more of the following CF1R-ALT-02-E Building Dept. replaced:Condenser Unit,Evaporator Coil, CF2R-MCH-01-E,MCH-20-H,MCH-(23 or 24)-H,MCH-25-H Compressor,TXV,Lineset,Furnace CF3R-MCH-20-H,MCH-(23 or 24)-H,MCH-25-H i , Installer Requirement:Duct leakage<5%,Air Flow 350 CFM/ton(or alternative),Refrigerant Charge 4 Exempted from duct leakage testing if:El 1. Existing duct systems are constructed,insulated or sealed with asbestos ❑4.New Ducting over 40 feet Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts' CF1R-ALT-02-E,CF2R-MCH-20-H,CF3R-MCH-20.H Installer Required to:Duct leakage(515%or,510%to outside or,or seal all accessible leaks) ❑ EXCEPTION:Existing duct systems constructed,insulated or sealed with asbestos. 'All new ducting requires R-8 insulation when more than 40 ft installed in CZs 11&14-16 and R-6 in CZs 1-10,12&13,and R-6 insulation when less than 40 ft installed.This includes in walls,between floors etc. 2 Heating only systems and Air Handler/Furnace changes do not require Air Flow MCH-(23 or 24),or Refrigerant Charge verification MCH-25 3 All New Ducts is when at least 75%of the duct system is new duct material,and up to 25%may consist of reused parts from the dwelling unit's existing duct system(e.g.,registers,grilles,boots,air handler,coil,plenums,duct material) "R-2.8 W'thick insulation)for linesets 1"and less. Contractor(Documentation Author's/Responsible Designer's Declaration Statement) I certify the following under penalty of perjury,under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24,Parts I and 6 of the California Code of Regulations(CCR). 4. That the energyfeatures and performance specifications,materials,components,and manufactured devices forthe building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24,Part I and Part 6 of the CCR. 5. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,worksheets,calculations,plans and specifications submitted to the enforcement agency for approval with this building permit application. g nsihle De" rName: �nible Di 'gnat S ig d CoWany• Address: Gty/State/Zip: `t : Phone: 779 oo e Cc.m ri 16is Cc Ger,6ca C,rI frl.,c- ' . r CA 9zsb2 I Gsl-6m-cs-7C0 For assistance or questions regarding the Energy Standards,contact the Energy Hotline at:1-800-772-3300