Loading...
PMT18-02009 City of Menifee Permit No.: PMT18-02009 29714 HAUN RD. Type: Residential Electrical <ACCELh? MENIFEE,CA 92586 MENIFEE Date Issued: 0 510 412 01 8 PERMIT Site Address: 29007 REDWOOD ST,MENIFEE,CA Parcel Number: 92584 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 1 INVERTER,2.24 kW LOT 33 Owner Contractor LENNAR HOMES OF CA,INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Oft Amount($1 Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APP L C.T O NI EE: L I A_ A El DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER , O/ OAW 1 PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129 Plan No. ,(o7� / a.aq kW/ PCS PROJECTADDRESS 29007 Redwood St Zip 92584 ASSESSOR'S PARCEL NUMBER LOT 33 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANTNAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES O NO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 G EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ $5.613.76 So FT L So FT APPLICANT'S SIGNATURE DATE CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL I CA-1) GREEN SMIP OWNER BUILDER VERIFIED OYES 0 NO DRIVERS LICENSE# NOTARIZEDLETTER 0 YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofmenifee.us I SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.240KW I I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 7 PCS.1 LG I LG320EIK-A5(320W) BUYER: INVERTER 7 PCS.1 ENPHASE I 106PLUS-72-ACM-US CITY OF MEN FEE ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION BUILDING AND S1 ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 7 NA NA NA BUYER: PR VAL TILT 18° NA' NA NA' PLAN A AZIMUTH 270° NA° NA' NA' City Ot IVIenifee DATE: --_— Building Dept. ,, ., REVIEWED APR 2 2uia Receive 0 `Approval of these pla s shall approval of,any violat on of ai 3' regulations and ordina tees. T S'-fi' jobsite until completi n. �s a LA= SOLADECK WIRE '--- TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE d UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX ` NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1678 ELEVATION A ENH-RIGHT ORIENTATION 3 LOT#33 ORIGINAL BY:ANGELA BURKE DATE:18.02.02 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE:18.02.05 CORONNA,A.C LA 9B0 I DRIVE,#302 REV.# BY DATE DESCRIPTION A 92879 namasb6 SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street304 INDIVIDUAL 29007 REDWOOD STREET Boulder,CO B0009 PLOT PLAN I I/16'=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY I QTY I MANUFACTURER MODEL NOTES TRADE 1 7 LG LG320EIK-A5(320W) ACPV MODULE W/ INTEGRATED ENPHASE 106PLU5-72-ACMiIS MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URE PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR TY 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 20A-2P.I X SA-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P,RATING MAY VARY SOLAR B I TBD TBD SERVICE PANEL.200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER,]PH,120/24OV,200A BLDR.ELEC. 10 1 TBD I TBD I GROUNDING ELECTRODE,UFER I BLDR. ELEC. A AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(IMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 he cons TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 OVISIOn TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 20 et of apl MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD.PART NUMBER AC MODULE SPEC L6320EIK-A5(320W) T17A•](MODS)= 8.19A OF CURRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(Dc) 320 8.19A X 1.25= 10.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE Pv BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT OAG) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREOUENCY/RANGE AC MODULE SPEC H2(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/ IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC QTY 7 BRANCH CIRCUIT OUTPUT, IMAXBC (IAC'MOD.QTY BC) AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD.QTY T 0TY 7 TOTAL SYSTEM OUTPUT IMAXTS 0AC'MOD.OTY T) AMPS(AC) 8.19 CONDUCTOR SIZING CALCULATIONS 0 CONDITION OF USE(COW: (AMPACITY• TEMP.DERATE -FILL DERATE)vs.REWD(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.Ls_ (IMAX- 1.25) KEY dSIZECU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD TYPE DERATES DERATE DERATE (A) (A) USED.(A) A CU THWN-2 COU 30 .76 1.0 22.80 8.19 TERM 25 25 10.24 20 B CU NM-B COU 40 .91 1.0 36.40 8.19TERM 35 35 10.24 20 C CU NM-B COU 40 .91 L0 36.40 8.19 TERM 35 35 10.24 20 CONDUCTOR SCHEDULE KEY CONDUCTORS LU/AL TYPE LOCATION TRADE A I-#12 ENPHASE Q CABLE,1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR B I3-#10•.FRIO EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 9 C 13410,1-#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 'NEUTRAL CAPPED AND NOT USED O— B 0 A 3 TO 8uF O � © MA- IN ' G—J A e c c =Io I I I ROOF EXTERIR-GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#33 ORIGINAL BY:ANGELA BURKE DATE:18.02.02 HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE.#302 REVIEWED BY:JIM PARKS I DATE:18.02.05 CORONA.CA 92879 REV.# BY DATE I DESCRIPTION Oniamasri§ SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4Bo Broadway Street 29007 REDWOOD STREET Boulder, CO4C 80009 PLOT PLAN 2 NTS ELECTRICAL MENIFEE.CA 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. ARTP 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 1�I 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH({9 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% ID 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 0 be a Pe TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER.TILE. :1 federal, BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ed plans mu ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/LEG. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SMALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250-122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- I5)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:ANGELA BURKE DAMS. LENNAR: 02.02 HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE18.O2.05 980 MONTECITO DRIVE.#302 CORONA,CA 92579 REV.# BY DATE DESCRIPTION nanI some DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29007 REDWOOD STREET B9Nder,CO 603N PLOT PLAN 3 NTS MENIFEE'CA NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. P )r,or an cr city kept on t SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION : ORIGINAL BY:ANGELA BURKE DATE18.02.02 LENNAR HERITAGE HEIGHTS REVIEWED BY:JIM PARKS I DATE i8.02.05 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, namasGe sOL.. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broady y SVeal INDIVIDUAL 29007 REDWOOD STREET BmIder,CO$0304 PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300 PLACARDS