Loading...
PMT18-02008 City of Menifee Permit No.: PMT18-02008 29714 HAUN RD. Type: Residential Electrical �ACCELA? MENIFEE,CA 92586 MENIFEE Date Issued: 0 510 412 01 8 PERMIT Site Address: 29044 REDWOOD ST,MENIFEE,CA Parcel Number: 92594 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 1 INVERTER,2.24 kW LOT 32 Owner Contractor LENNAR HOMES OF CA,INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing bulliding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permlt_Template.rpt Page 1 of 1 BUILDING.&SAFETY,P,ERMI_T/PLAN CHECKAP,P�ICATI:ON �A _ MENIFEE E,I L•INC% SaftTY DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA OSIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129 Plan No. 187`(1 a.aq kW/ —1 PCS PROJECT ADDRESS 29044 Redwood St zip 92584 ASSESSOR'S PARCEL NUMBER LOT 32 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ $5,613.76 SQ FT L SQ FT z� q APPLICANT'S SIGNATURE DATE I 111s CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: —1✓ CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL ,U0 GREEN SMIP 1 OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofinen ifee.us t SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MOD ESQI NCfidNE IFEI ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTAN IALLLYY IN THE - SYSTEM SIZE 2.2408W LOCATIONS INDICATED BY THE ILLUSTRATION. BUILDING A D S MODULE 7PCS. LG LG320EIK-A5(320W) BUYER: INVERTER 7PCS.COMPOSITE IO8EUNDE-ACM-US LAN PPR V�ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 J MOD OTY 7 NA NA NA BUYER: D TILT IB° NA' NA' NA' �,p AZIMUTH 270° NA' NA' NA° city Of Mendee DATE: Building DePt. Lse plan shag I APR 2 1 violati of am rdinan . Thl iv e d pletion WQy Q J LL `os ySOI-ADEC TRANSITION BOX WIRE TRANSITIO J j (UNDER ARRAY) / /✓� PV AC DISCONNECT EXTERIOR-GARAGE V UTILITY METER 8 I MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 1874 ELEVATION A ENH-LEFT ORIENTATION I LOT#32 LENNAR: ORIGINAL BY:ANGELA BURKE DATE:18.02.02 HERITAGE HEIGHTS 980 MONTECITO DRIVE.#302 REVIEWED BY:JIM PARKS I DATE:18.D2.05 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION namas;bA. ..IA. DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 2E044 REDWOOD STREET Boulder, e4 CO7030304 PLOT PLAN I I/Ib'=I'-0' MENIFEE.CA 303.447.03D0 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE C! KEY 7 LGNUFACTURER MODEL NOTES TRADE LG32 EIK-A5(320W) ACPV MODULE W/ INTEGRATED ENPHASE106PLUS-72-ACM-US MICROINVERTER SOLAR DEF 2 I 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR 4 I ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 I ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 20A-2P.I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TSD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR 8 1 TBD TSD SERVICE PANEL,200A BUS R.ELEC. 9 1 TBD TBD UTILITY METER.IPH.1201240V.200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. ' AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONJ D truedk ITEM NOTE/CALC UNIT DETAIL ITEM UNIT I PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMME 5 Of the TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •G -2 MAIN DISCONNECT AMPS 200 Proved F TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TELLTA) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 20 MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(32OW) I.I7A x)(MODS)= 8.I9A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(Oc) 320 8.I9A x 1.25= I0.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 2OA/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAc) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/ IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD.OTY Bc OTY 7 BRANCH CIRCUIT OUTPUT,IMAXBC (IAC-MOD.GTY Ba) AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD.GTY T OTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD.0TY T) AMPS(AC) 8.19 CONDUCTOR SIZING CALCULATIONS 0 CONDITION OF USE(COLD: (AMPACITY- TEMP.DERATE- FILL DEBATE)VS.REG'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. V5. REOD,(IMAX• 1.25) KEY SIZE I CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REOD OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A =#12CU =NM-BCOU 30 .76 1.0 22.80 8.19 25 25 10.24 20 B 40 .91 I.0 36.40 8.19 35 35 10.24 20 C 40 .91036.40 8.1935 35 10.24 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENPHASE Q CABLE.I46G,FREE AIR i CU I UL3003,DG CABLE I ARRAY I SOLAR B 3-#Ia•, Igo EGC I cU I NM-B(ROMEX) I INTERIOR ISOLAR C 3-#10,1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 9 'NEUTRAL CAPPED AND NOT USED M — 0 i a 4 30 O512P I O O T r7-1-7 Lu 2 z0uz 'N G ' G� Roor EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#32 ORIGINAL BY:ANGELA BURKE I DATE:18.02.02 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE:18.02:05 CORONA, NA,CA 92 DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION �2amasbd 1.1AX DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway,CO Street INDIVIDUAL 29044 REDWOOD STREET Boulder, 80304 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 203.447.030a INSTALLATION NOTES:SOLAR CONTRACTOR- U TML[ I ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.C. L 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH 49 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40% 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. I permil 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I'1 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 'Tall StBt 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SMALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. must bl TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS, 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERM114AL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINTIFINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UA.1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED.BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT P. I8)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:ANGELA BURKE DATEJ8.02.a2 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS I DATE18.02.05 980 MONTECITO DRIVE,#302 CORONA,CA 92879 qE DATE DESCRIPTION namastd — tiDWG TITLE: PAGE 4: SCALE: SITE LOCATION: reet INDIVIDUAL 4577 Broadway 304 PLOT PLAN 3 NITS 29044 REDWOOD STREET Boulder, 7. 30304 NOTES MENIFEE,C4 303.447.0300 I CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ( __ an `V on the SOLADECK WIRE TRANSITION BO% (UNDER ARRAY) PV AG DISCONNECT EXTERIOR-GARAGE UTILITY METER 6 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BO— < X SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE — AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8.19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:ANGELA BURKE DATE18.02.02 LENNAR: HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE18.02.05 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION V. namasGe CVd DWG TITLE: PAGE#: SCALE: SITE LOCATION: tISRst INDIVIDUAL 4571 Ber,CO 304 PLOT PLAN 4 NTS 29044 REDWOOD STREET Boulder,CO3CO PLACARDS MENIFEE,CA 303.447.03D0