PMT18-02008 City of Menifee Permit No.: PMT18-02008
29714 HAUN RD. Type: Residential Electrical
�ACCELA? MENIFEE,CA 92586
MENIFEE Date Issued: 0 510 412 01 8
PERMIT
Site Address: 29044 REDWOOD ST,MENIFEE,CA Parcel Number:
92594 Construction Cost: $5,613.76
Existing Use: Proposed Use:
Description of SOLAR TR 31582 HERITAGE HEIGHTS
Work: 7 MODULES, 1 INVERTER,2.24 kW
LOT 32
Owner Contractor
LENNAR HOMES OF CA,INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
SAMANTHA MAZELLA License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description Amount
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing bulliding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permlt_Template.rpt Page 1 of 1
BUILDING.&SAFETY,P,ERMI_T/PLAN CHECKAP,P�ICATI:ON �A _ MENIFEE
E,I L•INC% SaftTY
DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER
PLANNING CASE NUMBER
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA OSIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129
Plan No. 187`(1 a.aq kW/ —1 PCS
PROJECT ADDRESS 29044 Redwood St zip 92584
ASSESSOR'S PARCEL NUMBER LOT 32 TRACT 31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella lennar.com
APPLICANT NAME Lennar Homes of California Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO
BUSINESS NAME
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION
VALUATION$ $5,613.76 SQ FT L SQ FT z� q
APPLICANT'S SIGNATURE DATE I 111s
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION ACCEPTED BY: —1✓ CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE
INVOICE TOTAL ,U0 GREEN SMIP 1
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777
www.cityofinen ifee.us
t
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MOD ESQI NCfidNE IFEI
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTAN IALLLYY IN THE -
SYSTEM SIZE 2.2408W LOCATIONS INDICATED BY THE ILLUSTRATION. BUILDING A D S
MODULE 7PCS. LG LG320EIK-A5(320W) BUYER:
INVERTER 7PCS.COMPOSITE
IO8EUNDE-ACM-US LAN PPR V�ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 J
MOD OTY 7 NA NA NA BUYER: D TILT IB° NA' NA' NA' �,p
AZIMUTH 270° NA' NA' NA° city Of Mendee DATE:
Building DePt.
Lse plan shag I
APR 2 1 violati of am
rdinan . Thl
iv e d pletion
WQy
Q J
LL
`os
ySOI-ADEC
TRANSITION BOX WIRE
TRANSITIO J j
(UNDER ARRAY) / /✓�
PV AC DISCONNECT
EXTERIOR-GARAGE V
UTILITY METER 8 I
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOX
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
PLAN 1874 ELEVATION A ENH-LEFT
ORIENTATION I LOT#32
LENNAR: ORIGINAL BY:ANGELA BURKE DATE:18.02.02
HERITAGE HEIGHTS 980 MONTECITO DRIVE.#302 REVIEWED BY:JIM PARKS I DATE:18.D2.05
CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
namas;bA.
..IA.
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
4571 Broadway Street
INDIVIDUAL 2E044 REDWOOD STREET Boulder,
e4 CO7030304
PLOT PLAN I I/Ib'=I'-0' MENIFEE.CA 303.447.03D0
SYSTEM LAYOUT
ELECTRICAL EQUIPMENT SCHEDULE C!
KEY 7 LGNUFACTURER MODEL NOTES TRADE
LG32 EIK-A5(320W) ACPV MODULE W/ INTEGRATED ENPHASE106PLUS-72-ACM-US MICROINVERTER SOLAR DEF
2 I 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR
4 I ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR
5 I ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR
6 1 ENPHASE TBD PV BREAKER,I X 20A-2P.I X 5A-2P SOLAR
7 1 CUTLER-HAMMER TSD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR
8 1 TBD TSD SERVICE PANEL,200A BUS R.ELEC.
9 1 TBD TBD UTILITY METER.IPH.1201240V.200A BLDR.ELEC.
10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. '
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONJ D truedk
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT I PANEL
LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMME 5 Of the
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 BUS RATING AMPS 200
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •G -2 MAIN DISCONNECT AMPS 200 Proved F
TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40
TEMP,DELTA LOW(TELLTA) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 20
MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS:
MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(32OW) I.I7A x)(MODS)= 8.I9A OF CURRENT
MOD. POWER STC(P) AC MODULE SPEC WATTS(Oc) 320 8.I9A x 1.25= I0.24A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 2OA/2P 2 SPACE PV BACKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT(IAc) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741/ IEEE1547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD.OTY Bc OTY 7
BRANCH CIRCUIT OUTPUT,IMAXBC (IAC-MOD.GTY Ba) AMPS(AC) 8.19
AC MODULE QUANTITY,TOTAL MOD.GTY T OTY 7
TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD.0TY T) AMPS(AC) 8.19
CONDUCTOR SIZING CALCULATIONS
0 CONDITION OF USE(COLD: (AMPACITY- TEMP.DERATE- FILL DEBATE)VS.REG'D(IMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS. V5. REOD,(IMAX• 1.25)
KEY SIZE I CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REOD OCD
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A =#12CU =NM-BCOU
30 .76 1.0 22.80 8.19
25 25 10.24 20
B 40 .91 I.0 36.40 8.19
35 35 10.24 20
C 40 .91036.40 8.1935 35 10.24 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A -#12 ENPHASE Q CABLE.I46G,FREE AIR i CU I UL3003,DG CABLE I ARRAY I SOLAR
B 3-#Ia•, Igo EGC I cU I NM-B(ROMEX) I INTERIOR ISOLAR
C 3-#10,1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 9
'NEUTRAL CAPPED AND NOT USED
M —
0 i a
4 30
O512P
I
O O T r7-1-7
Lu
2
z0uz
'N
G ' G�
Roor EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.24OKW
LOT#32
ORIGINAL BY:ANGELA BURKE I DATE:18.02.02
HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE:18.02:05
CORONA,
NA,CA 92 DRIVE,#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
�2amasbd
1.1AX
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4571 Broadway,CO Street
INDIVIDUAL 29044 REDWOOD STREET Boulder, 80304
PLOT PLAN 2 NTS
ELECTRICAL MENIFEE,CA 203.447.030a
INSTALLATION NOTES:SOLAR CONTRACTOR-
U TML[
I ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.C. L
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH 49 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40%
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION. I permil
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I'1 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 'Tall StBt
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SMALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. must bl
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS,
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERM114AL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINTIFINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UA.1703,IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED.BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT P.
I8)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:ANGELA BURKE DATEJ8.02.a2
HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS I DATE18.02.05
980 MONTECITO DRIVE,#302
CORONA,CA 92879 qE
DATE DESCRIPTION
namastd
— tiDWG TITLE: PAGE 4: SCALE: SITE LOCATION:
reet
INDIVIDUAL 4577 Broadway 304
PLOT PLAN 3 NITS 29044 REDWOOD STREET Boulder, 7. 30304
NOTES MENIFEE,C4 303.447.0300
I
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN. ( __
an
`V
on the
SOLADECK WIRE
TRANSITION BO%
(UNDER ARRAY)
PV AG DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 6
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BO— <
X
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE — AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 8.19A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:ANGELA BURKE DATE18.02.02
LENNAR:
HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE18.02.05
980 MONTECITO DRIVE,#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION V.
namasGe
CVd
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
tISRst
INDIVIDUAL 4571 Ber,CO 304
PLOT PLAN 4 NTS 29044 REDWOOD STREET Boulder,CO3CO
PLACARDS MENIFEE,CA 303.447.03D0