PMT18-02006 City of Menifee Permit No.: PMT18-02006
29714 HAUN RD. Type: Residential Electrical
ACC UL MENIFEE, CA 92586
s119pT' MENIFEE Date Issued: 0 510 412 01 8
PERMIT
Site Address: 29076 REDWOOD ST,MENIFEE,CA Parcel Number:
92584 Construction Cost: $8,420.00
Existing Use: Proposed Use:
Description of SOLAR TR 31582 HERITAGE HEIGHTS
Work: 10 MODULES, 1 INVERTER,3.20 kW
LOT 30
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
SAMANTHA MAZELLA License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description Q�l Amount(Sl
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA Bldg_Pennit Template.rpt Page 1 of 1
ILDING &.SAFETY PERMIT�PLAN CHECK APPLICATION MENIFE
I
DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER 1 '
PLANNING CASE NUMBER
TYPE: O COMMERCIAL O RESIDENTIAL 0 MULTI-FAMILY 0 MOBILE HOME 0 POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION 0 DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129
Plan No.ww/ 3, 010 kW/ )D PCS
PROJECTADDRESS 29076 Redwood St zip 92584
ASSESSOR'S PARCEL NUMBER LOT 30 TRACT 31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella lennar.com
APPLICANTNAME Lennar Homes of California Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO
BUSINESS NAME
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER `73-�1�a LICENSE CLASSIFICATION
VALUATION$ ?7I J�C,,1'p sSOFT L SO FT q G
APPLICANT'S SIGNATURE D 1 I' `��'�(J' DATE
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE
INVOICE TOTAL I 4.W I GREEN I SMIP
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE N NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586(951)672-6777
www.cityofm en i fee.us
NI
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 3.200 KW I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE IO PCS.1 LG I LG320EIK-AS(320W) BUYER:
INVERTER IO PCS.1 ENPHASE I 106PLUS-72-ACM-US
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: 1.SUB-ARRAY INFORMATION CITY OF MENIF E
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 10 NA NA NA BUYER: AND AFI
TILT 23° NA' NA. NA' City of Merniee DATE: PLAN DUILLANU AZIMUTH 270- NA' NA• NA' Building Dept. L
APR 2 / 2013
REVIEWED
kj
R ,cpived
'Approval of these plans st all not I
approval of,any violation o any po
regulations and ordinances. This u
jobsite until completion.
r�
10
SOLADECK
�a
a�
pLL
ci
TRRANSITIOANSITIO
N BOX
(UNDER ARRAY) .. _. .--
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER&
MAIN SERVICE PANEL
(VERIFIED BY BUILDER) _,-__„'
AC COMBINER BOX
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
PLAN 2686 ELEVATION B ENH-LEFT
ORIENTATION I LOT#30
LENNAR: ORIGINAL BY:ANGELA BURKE DATE:IB.O2.02
HERITAGE HEIGHTS 980 REVIEWED BY:JIM PARKS DATE:18.02.05
CORONNA,A,C CA A 92 DRIVE.#302 679 REV.# BY DATE I DESCRIPTION
namasbi§
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29076 REDWOOD STREET Boulder,CO W0
PLOT PLAN 1116'=I'-0' MENIFEE.CA 303,447.0300
SYSTEM LAYOUT
ELECTRICAL EQUIPMENT SCHEDULE
KEY .CITY MANUFACTURER MODEL NOTES TRADE
I 10 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE IQ6PLUS-72-ACM-US MICROINVERTER SOLAR
2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV.30A SOLAR
4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR
5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR
6 1 ENPHASE TBD PV BREAKER.I X 2OA-2P,1 X 5A-2P SOLAR
7 1 CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P.RATING MAY VARY SOLAR
8 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. DEI
9 1 TBD TBD UTILITY METER, IPH, 1201240V,200A BLDR.ELEC.
)0 I TBD TBD GROUNDING ELECTRODE.UFER BLDR.ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 1 40
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 1 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: -J
MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 1.17A X f(MODS)= IIJOA OF CURRENT SInIBdII
MOD.POWER STC(P) AC MODULE SPEC WATTS(nU 320 11.70A X 1.25= I4.63A ic ns ofu!
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 2OA/2P 2 SPACE PV BACKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 10 N•�•�E
NOMINAL VOLTAGE/RANGE AC MODULE SPEC. VOLTS(AC) 240/211-264 MV•^I
NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HE(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741/IEEEI547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC OTY 10
BRANCH CIRCUIT OUTPUT,IMAXBC (IAC°MOD.OTY 80 AMPS(AC) 11.70
AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 10
TOTAL SYSTEM OUTPUT IMAXTB (IAC°MOD.QTY T) AMPS(AC) U.70
CONDUCTOR SIZING CALCULATIONS
U CONDITION OF USE(COU): CAMPACITY ' TEMP. DERATE °FILL DERATE)vs.REO'D(TMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS.m REQ'D,(IHAX ° 1.25)
KEY S12E I LU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A #12 CU THWN-2 COU 30 .76 1.0 22.80 11.70
TERM 25 25 14.63 20
B #ICI Cu NM-B COU 40 .91 1.0 36.40 11.70
TERM 35 35 14.63 20
C #10 CU NM-B COU 40 .91 1.0 36.40 11.70
TERM 35 35 14.63 20
CONDUCTOR SCHEDULE
KEY I CONDUCTORS CU/AL TYPE LOCATION TRADE
A I-#12 ENPHASE 0 CABLE,1-#6G,FREE AIR I Cu it UL3003.DG CABLE I ARRAY SOLAR 9
B 3-#10•.I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
C 1 3410,1410 EGC Cu NM-B(ROMEX) I INTERIOR I SOLAR O
'NEUTRAL CAPPED AND NOT USED
0
IB
4 m O
O Sala 7
L20A/IP
_ _
�N
G ' G
A B C C = 10
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 3.20OKW
LOT#30
ORIGINAL BY:ANGELA BURKE DATE:18.02.02
HERITAGE HEIGHTS LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:18.02.05
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
�Pnamast;6
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
INDIVIDUAL 4571 Bro,CO 8Street
2907fi REDWOOD STREET Boulder,CO
PLOT PLAN 2 NTS
ELECTRICAL MENIFEE.CA 303.447.0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. _
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 20I6 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(})SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND ME?
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(11 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF SAVE.PEEL-N-STICK BAS
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS,
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EA
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
rmitN
z al,stale)
.Rs mustInI
ELECTRICAL NOTES:
GENERAL-
I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SMALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
6)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
I5)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES,
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT V
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:ANGELA BURKE DATE)8.02.02
HERITAGE HEIGHTS 980 MOLENNAR: REVIEWED BY:JIM PARKS DATE)8.02.05
980 NA.CA I92 DRIVE.#302 REV.# BY DATE DESCRIPTION
CORONA,CA 92879
Samastifi
sous
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
4571 Broadway Street
INDIVIDUAL 29076 REDWOOD STREET BONIEBf,C080304
PLOT PLAN 3 NTS
NOTES
MENIFEE,CA 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
V
fit tIR
in
on the
SOL DECK WIRE
TRANSITION 90%
(WIDER ARRAY)
PV AC DISCONNECT
EXTEWOR-GARAGE
UTILITY METER a
MAIN SERVICE PANEL
(VERIFIED RY BUILDER)
AC COMBINER.M.
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 11.70A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
HERITAGE HEIGHTS LENNAR: ORIGINAL BY:ANGELA BURKE I DATE) .O2.02
REVIEWED BY:JIM PARKS DATE18.02.05
CORONNA.A,C CA 92 879
C DRIVE.#302 REV.# BY DATE DESCRIPTION •�
CORONA,
namasb6
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Sveel
INDIVIDUAL 29076 REDWOOD STREET Boultler,C080304
PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300
PLACARDS