Loading...
PMT18-02005 City of Menifee Permit No.: PMT18-02005 29714 HAUN RD. Type: Residential Electrical �.ACCELX1' MENIFEE,CA 92586 MENIFEE Date Issued: 05/04/2018 PERMIT Site Address: 29103 REDWOOD ST, MENIFEE,CA Parcel Number: 92584 Construction Cost: $8,420.64 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 10 MODULES, 1 INVERTER,3.20 kW LOT 40 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description City Amount f$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when In violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 UIL .NG 5 , FETY-PERMIT.P C.E P LI T O E WE u f DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER V PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129 Plan No. P(o[ 71 3 •,10 kW/ 10 PCS PROJECTADDRESS 29103 Redwood St zip 92584 ASSESSOR'S PARCEL NUMBER LOT. 40 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 G EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBERS n�(oZ 6 �d a' LICENSE CLASSIFICATION ICI' VALUATION$ - ".,/0V''(4/SQ FT L SQ FT �j I �i APPLICANT'S SIGNATURE Ol I DATE CITY STAFF USE ONLY 11111&_ DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICETOTAL GREEN SMIP ' OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZEDLETTER O YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92S86 (951)672-6777 ___ www.cityofmenifee.us NIF ti.i SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTV 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN SYSTEM SIZE 13.20OKW LOCATIONS INDICATED BY THE ILLUS.TRAAeN. II.���� MODULE IOPCS. LG LG320EIK-A5(320W) BUYER: ( FNIFEE INVERTER I IOPCS.1 ENPHASE I IO6PLUS-72-ACM-US E ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAV#I ARRAY#2 ARRAY#3 ARRAY#4 AN AppROVAL MOD OTY IO NA NA NA ,n ,{ BUYER: TILT 23' NA' NA' NA' City of Mentfee DATE: AZIMUTH 271• NA' NA' NA' Building Dept. APR 2 r 2i1+3 L D RQ^�i"p/^� ese planssha notbe Received iV ee •u ny violation of ny prod ordinances. hisset completion. �g P LL d Amy! IIm SOL ANELK WIRE TRANSITION _I TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 6 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2687 ELEVATION B-RIGHT ORIENTATION 3 LOT#40 LENNAR: ORIGINAL BY:T HAMMERBACHER DATE:I8.0I.16 HERITAGE HEIGHTS 980 MONTELITO DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS I DATE:18.01.17 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vniamasr6 SOIAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 VA M sler Cirde INDIVIDUAL 29103 REDWOOD STREET Suite 700 PLOT PLAN 1 1/16'=P-0` MENIFEE.CA Boulder.CO 80301 SYSTEM LAYOUT I 303.447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY CITY I MANUFACTURER MODEL NOTES TRADE 1 10 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR C 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR )EPP 4 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 2OA-2P,I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,LIFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER ;trued I TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 RS Df th' TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TEELTA) TMIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 pproved MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-AS(320W) LDA X 10(MOD.5)= II.26A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(00) 320 IVOA x 1.25= 14.63A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV 34CKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT OAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC H2(AC) 60 159.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL174I/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. CITY INC OTY 10 BRANCH CIRCUIT OUTPUT. IMAXBC (IAC•MOD.GTY BC) AMPS(AC) 11.70 AC MODULE QUANTITY,TOTAL MOD. OTY T CITY 10 TOTAL SYSTEM OUTPUT IMAXTS 0AC•M0D. CITY T) AMPS(AC) 1270 CONDUCTOR SIZING CALCULATIONS D CONDITION OF USE(COU): EDERATES MP.DERATE • FILL DEBATE)VS.REQD(IMAX) 2)TERMINALS(TERM): ERMINALS.vs.READ,(IMAX• 1.25) KEY SIZE CU/AL INSULATION CALL' LL RESULT REO'D OCDTYPE DEBATE DEBATE (A) W LISED(A) A #12 CU THWN-2 COU .76 1.0 22.80 11.70 TERM 25 14.63 20 B #10 CU NM-B COU .91 1.0 36.40 IL70 TERM 35 14.63 20 C #10 CU NM-B COU .91 1.0 36.40 11.70 TERM 35 14.63 1 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENPHASE 0 CABLE,1-960,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR B 3-#10`.I410 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 9 C 3-*10.1410 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 'NEUTRAL CAPPED AND NOT USED O- Q 4 Q3 O 5u2P O 6 0 6 0A/ z 0G/ _IN A B C C =10 ROOF EXTERIOR GARAGE ELECTRICAL DIAGRAM 3.20OKW LOT#40 ORIGINAL BY:T HAMMERBACHER DATE:I LENNAR: 980 MONTECITO DRIVE,#302 B.01.16 HERITAGE HEIGHTS REVIEWED BY:DESIREE WILLIAMS I DATE:18.01.17 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Pniamasreli sou. DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 VSuite 700 Circle PINDIVIDUAL MENI REDWOOD STREET Suite O8 PLOT PLAN 2 NTS MENIFEE,CA Boulder,C08OO ELECTRICAL 303.4A7.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(})SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR.ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION, IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. :B!fflltl 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 31,State 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. must b) BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTESNOTES- GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- ])MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY HAMMERBACHER I DATE18.01.16 HERITAGE HEIGHTS LENNAR: REVIEWED BY:DESIREE WILLIAMS I DATE18.01.17 980 MONTECITO DRIVE, #302 CORONA.CA 92879 REV.# 8Y DATE I DESCRIPTION narnast;6 SOIL[ DWG TITLE: PAGE#: SCALE: SITE LOCATION: 8]0]Vdufte 70 t Circle INDIVIDUAL MENU REDWOOD STREET SMe CO PLOT PLAN 3 NTS MENIFEE.CA Boulder.34447d 3OO NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 1 I SULADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENORIGINAL BY:T HAMMERSACHER DATEiB.01.16 980 MONTECITO DRIVE,#302 HERITAGE HEIGHTS : REVIEWED BY:DESIREE WILLIAMS DATEJB.01.17 80 CORONA,CA 92879 REV.# BY DATE DESCRIPTION tit mast;6 SOLI.X DWG'TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VVr'.ler Circe INDIVIDUAL 29103 REDWOOD STREET Suite 700 PLOT PLAN 4 NITS MENIFEE,CA Boulder,CO 80301 PLACARDS I 303.447.0300