PMT18-02004 City of Menifee Permit No.: PMT18-02004
29714 HAUN RD. Type: Residential Electrical
<—ACCELA MENIFEE,CA 92586
MENIFEE Date Issued: 0 510 412 01 8
PERMIT
Site Address: 29089 REDWOOD ST,MENIFEE,CA Parcel Number:
92584 Construction Cost: $5,613.76
Existing Use: Proposed Use:
Description of SOLAR TR 31582 HERITAGE HEIGHTS
Work: 8 MODULES, 1 INVERTER,2.56 kW
LOT 39
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
SAMANTHA MAZELLA License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description City Amount f51
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced Is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bidg_Permit_Template.rpl Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE
L§L �•I/J', SA�'ET 1'
DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER '
PLANNING CASE NUMBER
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129
Plan No. o'13)/ a. elo kW/ s' PCs
PROJECTADDRESS 29089 Redwood St Zip 92584
ASSESSOR'S PARCEL NUMBER LOT 39 TRACT 31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella lennar.com
APPLICANT NAME Lennar Homes of California Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO
BUSINESS NAME
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 l EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER `c�'�Qc�- LICENSE CLASSIFICATION
VALUATION$ �-rj' ID 13,1(PSQ FT L So FT �i
APPLICANT'S SIGNATURE DATE g1l11 0
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIR61 E
INVOICETOTAL . �(� GREEN i SMIP l
OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777
www.cityofinen ifee.us
NI
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODU R5 T_O BE INSTALLED
ITEM OTY MFR. 1 MODEL ON TH ORSO OF TED HHOME
WILL
ILLBE SUB IONN IALL�I", OF ME IFEI
SYSTEM SIZE 2.560XW
MODULE 8 PCS.1 LG I LG320EIK-A5(320W) BUYER: G A D v INVERTER 8PCS. ENPHASE 106PLUS-72-ACM-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: PLAN AppR VAI SUB-ARRAY INFORMATION
ARRAY#I 1 ARRAY#2 1 ARRAY#3 ARRAY#4
Moo QTY IB' NA NA' N8 MA NA A.
City of Nlenrfee BUYER:
AZIMUTH 271° 1 NA' I NA° NA° Building Dept. DATE:
APR 2 t 201"1
`Approval of these 1 ans sh
apprReceived, regulationval s
and any
' not
(� I regulations and ordi sous.
I jobsite unfit com on°
SOL
P
}Z
o- oLL
Om /
ADECK WIRE TRANSITION
TRANSITION BOX - --
(UNDER ARRAY)
PV DISCONNECT
EXTERIOR-GARAGE W �
UTILITY METER 8 Q
g MAIN SERVICE PANEL
(VERIFIED BY BUILDER) II
AC COMBINER BOX
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2131 ELEVATION A RIGHT
ORIENTATION 3 LOT#39
LENNAR: ORIGINAL BY:T HAMMERBACHER DATE: 18.01.16
HERITAGE HEIGHTS 980 I DRIVE.#302 REVIEWED BY:DESIREE WILLIAMS DATE: 18.01.17
CORONNA,A,C CA A 92879 REV.# BY DATE DESCRIPTION •,
namast;6
SO",
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
6707 Winchester Circle
INDIVIDUAL 29089 REDWOOD STREET Suite 700
O8
PLOT PLAN I/16'=I'-0' MENIFEE.CA BOWde0301
SYSTEM LAYOUT 303.U70844].0300
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE
I B LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR
2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NE14A 3R SOLAR TM C
3 1 CUTLER-HAMMER DG22IURB PV AC DISCONNECT.NEMA 3R.24OV,30A SOLAR
4 1 ENPHASE 10 ENVOY ENV-IOAMI-240 PV DATA MONITOR.240V SOLAR
5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR
6 I ENPHASE TBD PV BREAKER,I X 20A-2P.I X 5A-2P SOLAR
7 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR
B I TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC.
9 1 TBD TBD UTILITY METER,IPH,120/24OV.200A BLDR.ELEC.
10 I TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL I) COOST
LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 0 ISIOIIS I
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 '!$ Q OI appn
TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS:
MOD.PART NUMBER AC MODULE SPEC LG320EIK-AS(32OW) I.I7A X B(MOD9= 9.36A OF CURRENT
MOD.POWER STC(P) AC MODULE SPEC WATTS(DC) 320 9.36A X 1.25= IL70A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREOUENCY/RANGE AC MODULE SPEC Hz(AC) 60 159.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741/IEEE1547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AL MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. QTY BC OTY 8
BRANCH CIRCUIT OUTPUT.IMAXBC (IACMOD.OTY BC) AMPS(AW 9.36
AL MODULE QUANTITY,TOTAL MOD.OTY T QTY 8
TOTAL SYSTEM OUTPUT IMAXTS OAC•MOD.OTY T) AMPS(ACI 9.36
CONDUCTOR SIZING CALCULATIONS
U CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE •FILL DERATE)vs.REDID(IMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REG'D.(IMAX• 1-25)
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A #1 CCU THWN-2 COU 30 .76 1.0 22.80 9.36
TERM 25 25 11.70 Ezod
B #10 CU NM-B COU 40 .91 1.0 36.40 9.36
TERM 35 35 11.70
C #10 CU NM-B COU 40 .91 1.0 36.40 9.36
TERM 35 35 11.70
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENPHASE 0 CABLE.I46G,FREE AIR I Cu I UL3003,DG CABLE I ARRAY I SOLAR
B 1 3410•.1410 EGG I CU I NM-B(ROMEX) I INTERIOR I SOLAR t
C 3-#10,1-#10 EGG CU NM-B(ROMEX) INTERIOR SOLAR
'NEUTRAL CAPPED AND NOT USED 4 eQ330A/}P
G ' U G�
I I 1
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.56OKW
LOT#39
LENNAR: ORIGINAL BY:T HAMMERBACHER I DATE: 18.01.16
HERITAGE HEIGHTS REVIEWED BY:DESIREE WILLIAMS DATE: 1B.01.17
CORNA,CA 92 DRIVE.#307
CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
Pniannasr6
soAAv
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
6707 VSuite 7 0 Circe
INDIVIDUAL 29089 REDWOOD STREET der, 8
PLOT PLAN 2 NTS MENIFEE.CA Boulder,CO O30301
ELECTRICAL 3O3.417.0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. ���
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
ID 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 09 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE r0 a
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SMALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. d
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
st
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. 'j p ins mm
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690,12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC.WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPRASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS.WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT k.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:T HAMMERRACHER DATE:18.0L16
LENNAR:
HERITAGE HEIGHTS REVIEWED BY:DESIREE WILLIAMS I DATE:18.01.17
980 MONTECITO DRIVE,#302
CORONA,CA 92579 REV.# BY DATE DESCRIPTION •,
namasb�
DWG TITLE: PAGE#: I SCALE: rCirxl
SITE LOCATION: 6707 W9rIte70 rCircle
INDIVIDUAL 29089 REDWOOD STREET der, O8
PLOT PLAN 3 NTS MENIFEE.CA Bo3D3."7080001
NOTES
303.44].0300
_I
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN. �/v)
'D�T
i Ora
Jty
.it on the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER&
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOX
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 9.36A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:T HAMMERBACHER DATE:18.01.16
HERITAGE HEIGHTS LEN14AR:
980 MONTECITO DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS I DATE:18.01.17
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Vnamasr6
501At
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
6707 Witollester Circle
INDIVIDUAL 29089 REDWOOD STREET r, 700
CO
PLOT PLAN 4 NTS MENIFEE.CA
Bouldetler, O 80307
PLACARDS 303447.0300