PMT18-02003 City of Menifee Permit No.: PMT18-02003
29714 HAUN RD. Type: Residential Electrical
19-;CCELA MENIFEE,CA 92586
MENIFEE Date Issued: 0 5/0 412 01 8
PERMIT
Site Address: 29075 REDWOOD ST,MENIFEE,CA Parcel Number:
92584 Construction Cost: $5,613.76
Existing Use: Proposed Use:
Description of SOLAR TR 31582 HERITAGE HEIGHTS
Work: 7 MODULES, 1 INVERTER,2.240 kW
LOT 38
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
SAMANTHA MAZELLA License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description QQttt Amount!$)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing bulliding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bidg_Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION - MENIFEE
DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER '!J
PLANNING CASE NUMBER
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129
PlanNo.jlp-7,'/ c)•aLlb kW/ —1 PCs
PROJECTADDRESS 29075 Redwood St zip 92584
ASSESSOR'S PARCEL NUMBER LOT 38 TRACT 31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella lennar.com
APPLICANTNAME Lennar Homes of California Inc.
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES O NO
BUSINESS NAME
ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER `1 spa LICENSE CLASSIFICATION TT
VALUATION$ $5,613.76 SQ FT L SQ FT G�J
APPLICANT'S SIGNATURE a Y Y 1/'.1 DATE
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE
INVOICETOTAL II GREEN SMIP
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586(951)672-6777
www.cityofmenifee.us
NIF
r
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM GTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBS NT L
SYSTEM SIZE 2.240KIN LOCATIONS INDICATED BY THE ILLUSTRATI �`YTS t' MENI EE
MODULE 7PCS. LG LG320EIK-A5(320W) BUYER:— �T't. AN SAS
INVERTER 7PCS. ENPHASE 106PLUS-72-ACM-US " " '
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: R�SUB-ARRAY INFORMATION L
AN AP AL
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 7 NA NA NA BUYER:
TILT 18' NA' NA' NA'
AZIMUTH 271' NA' NA' NA' DATE:
-368'lm Be
City of Men'tfee
Building Dept, Approval of these plans ghall nc
approval of.any violation of any
APR 2 r 20 o rqulations and ordinanc s. This
jobsite until completion.
Received
cLm
cm
,_
p� LAM
as
SOLADECK WIRE
TRANSITION V
(UNDER ARRAY))
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER a
MAIN SERVICE PANEL /�
(VERIFIED 8Y BUILDER) (-�`�/
AL COMBINER BOX
4� �o
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 1678 ELEVATION B-RIGHT
ORIENTATION 3 LOT#38
ORIGINAL BY:T HAMMERBACHER I DATE:18.01.Ifi
HERITAGE HEIGHTS LENNAR:
980 I DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17
CORONNA,A.C CA A 922879 REV.# BY DATE DESCRIPTION I
i namastl
EOIA!
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
INDIVIDUAL 6707 Vdnte 700 Circe
29075 REDWOOD STREET Suite O,8
PLOT PLAN I 1/16'=I'-0' MENIFEE,CA Boulder,303.4 C080301
SYSTEM LAYOUT 303.E4].0300
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY I MANUFACTURER MODEL NOTES TRADE
1 7 1 LG LG320EIK-A5(320W0 ACPV MODULE W/INTEGRATED ENPHASE 11)6PLUS-72-ACM-US MICROINVERTER SOLAR DE
2 1 1 RSTC/SOLADELK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR
4 I ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR.240V SOLAR
5 I ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR
6 I ENPHASE TBD PV BREAKER.I X 20A-2P,I X 5A-2P SOLAR
7 I CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P,RATING MAY VARY SOLAR
8 I TBD TBD SERVICE PANEL,200A BUS BLUR.ELEC.
9 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC.
To I TBD TBD GROUNDING ELECTRODE,UFER BLUR.ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT I PANEL n$wQ1
LOCATION MENIFEE,CA PANEL MFR. I CUTLER-HAMMER
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 1 200 OIL$Of I
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 1 200
TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 140 (approve
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20
MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS:
MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(32OW) LIM X 7(MODS)= e.19A OF CURRENT
MOD.POWER STC(P) AC MODULE SPEC WATTS(0c) 320 SARA X LES= 10.24A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A72P 2 SPACE PV BADKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 2BO
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT(Ad AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741 /IEEEI547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC QTY 7
BRANCH CIRCUIT OUTPUT,IMAXBC 0AC'MOD.OTY SO AMPS(AC) 8.19
AC MODULE QUANTITY.TOTAL MOD. OTY T QTY 7
TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD.QTY T) AMPS(AC) 1 8.19
CONDUCTOR SIZING CALCULATIONS
U CONDITION OFUSE(COU): (AMPACITY- TEMP.DERATE-FILL DERATE)VS.REWD(TMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS.VXa.REO-D,(IMAX • 1.25)
KEY SIZE CU/AL INSULATION CALC' AMPACITY W/0 TEMP. FILL RESULT REOD OCD
TYPE BERATES DERATE DERATE (A) (A) USED(A)
A t#12CUTHWN-2 COU 30 .76 1.0 22.80 8.19
TERM 25 25 10.24 20
B NM-B COU 40 .91 1.0 36.40 8.19
TERM 35 35 10.24 20
C NM-B COU 40 .91 1.0 36.40 8.19
TERM 35 35 I0.24 20
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS LU/AL TYPE 1.LOCATION TRADE
A FUN ENPHASE Q CABLE,I-#6G,FREE AIR CU UL3003.DG CABLE ARRAY SOLAR
B 1 3-#10-.1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 9
C 1 3-#10,1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
'NEUTRAL CAPPED AND NOT USED O—
B
A e Q3
ID TSIP O
AI
0 6 L.
2
zmrzP
AN
GTr 6 G�
A B C C — ID
I 1 I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.24OKW
LOT#38
LENNAR: ORIGINAL BY:T HAMMERBACHER DATE:18.01.16
HERITAGE HEIGHTS REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17
CORONNA,CA
980 A.CA I 2 DRIVE,#302
42879 REV.# BY DATE DESCRIPTION
namasbmi
..IAA
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
6]W VSuote 7 0 Circle
INDIVIDUAL 29075 REDWOOD STREET Guile O B
PLOT PLAN 2 NT5 MENIFEE,LA Boulder,CO
ELECTRICAL 303.447.0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. ARTMI
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
IL)26 GAUGE INTERLOCKING FLASHING'SIDEWAI TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE I
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. °a per'
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE,COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. erol
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. S OIUS2I
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A.WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:T HAMMERBACHER DATE18.
980 01.16
HERITAGE HEIGHTS 80 MO:NTECITO DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS DATE18.01.17
CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
namasW
�OLAI
DWG TITLE: PAGE#: SCALE: SITE LOCATION: S.
INDIVIDUAL 67W VSwW 700
Circle
PLOT PLAN 3 NTS 29075 REDWOOD STREET der.CO
MENIFEE,CA Bo303.4 7. 8 D
NOTES 3D8.447.0300
r
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
or an
city
:pt on the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER IN
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOX
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 8. 19A
I PC., NEC 690.54 1 PC., NEC. 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:T HAMMERBACHER DATEd8.01.16
980
HERITAGE HEIGHTS 80 MO
NTELITD DRIVE.#3D2 REVIEWED BY:DESIREE WILLIAMS DATH8.01.17
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Vmnri
SOIA!
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
6707 Vdnchester Circle
INDIVIDUAL 29075 REDWOOD STREET Suite 70D
PLOT PLAN 4 NITS MENIFEE.CA Boulder,CO 80301
PLACARDS 303.447.0300