Loading...
PMT18-02002 City of Menifee Permit No.: PMT18-02002 29714 HAUN RD. �A-CCF1./� MENIFEE,CA92586 Type: Residential Electrical MENIFEE Date Issued: 0 510 412 01 8 PERMIT Site Address: 29100 REDWOOD ST, MENIFEE,CA Parcel Number: 92584 Construction Cost: $6,315.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 8 MODULES, 1 INVERTER,2.56 kW LOT 29 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Of( Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILp1N. &. AFE ERM T PLAN G.ECK.A_FPJ LGAiIANMENIF"E DATE: 4/1 912 0 1 8 PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129 Plan No. 3131 / g .+j(o kW/ p PCS PROJECTADDRESS 29100 Redwood St zip 92584 ASSESSOR'S PARCEL NUMBER LOT 29 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 G EMAIL samantha.mazella lennar.com CONTRACTOR'S STATE LIC NUMBER ,ap �.Da' LICENSE CLASSIFICATION VALUATION S 8 UZp)5,'11QsQ FT L SQ FT q APPLICANT'S SIGNATURE DATE DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE TOTAL �7j,U0 GREEN SMIP U OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER G YES 0 NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586(951)672-6777 www.cityofinen ifee.us NIF SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MI MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.56OKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8PCS.1 LG LG320EIK-A5(32OW) BUYER: INVERTER 1 8 PCS.1 ENPHASE I IQ6PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: NIF E SUB-ARRAY INFORMATION CITY OF ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 I AND SAF MOD CITY 8 NA NA NA BUYER;- TILT IF NA° NA' NA' City lot Mentfee DATE: AZIMUTH 271° NA' NA' NA° Building Dept. APR 2 f 'T ' REVIEWED Received 'Approval of these plans s hall not 5'-6 3' approval of,any violation any p regulations and ordinancet This jobsite until completion. a— aa ) SOLADECK WIRE TRANSITION BOX (IdJDER ARRAY)) EXT F' L n_ PV E DISCONNECT - - ERIOR-GARAGE r- + UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) y a AC COMBINER BOX �I �W NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 2131 ELEVATION B ENH-RIGHT ORIENTATION I LOT#29 ORIGINAL BY:T HAMMERBACHER DATEAB.01.18 HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS I DATEABLO1.17 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namast€ sosAe DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Wnchester Cir e INDIVIDUAL 29100 REDWOOD STREET Suite 700 PLOT PLAN I 1/16'=1'-0' MENIFEE.CA B.Ider,CO 80301 SYSTEM LAYOUT 303447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 8 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG22IURB PV AC DISCONNECT,NEMA 3R.24OV,30A SOLAR 4 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 20A-2P.I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR TM C B I TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER,[PH.120/24OV.200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN •C -2 MAIN DISCONNECT AMPS 200 TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 20 ;Onst MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) I.17A X B(MODS)= 9.36A OF CURRENT r011S MOD.POWER STC(P) AC MODULE SPEC WATTS(DO) 320 9.36A X 1.25= 11.70A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20Al2P 2 SPACE PV RACKI EED BREAKER GI appr MAX CONTINUOUS OUTPUT POWER STC(P) AL MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AU 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREGUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC ULI741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC OTY 8 BRANCH CIRCUIT OUTPUT,IMAXBC DAC°MOD.QTY BO) AMPS(AC) 9.36 AL MODULE QUANTITY,TOTAL MOD.OTY T QTY 8 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD.QTY T) AMPS(AC) 1 9.36 CONDUCTOR SIZING CALCULATIONS I)CONDITION OF USE(COU): (AMPACITY°TEMP, DERATE `FILL DEBATE)Y§:REQ'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REO'D.(IMAX° 1.25) KEY 812E CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THAI COU 30 .76 1 1.0 22.80 9.36 TERM 25 25 11.70 20 B #10 CU NM-B COU 40 .91 1.0 36.40 9.36 TERM 35 35 11.70 20 C #10 CU NM-B LOU 40 .91 1.0 36.40 9.36 TERM 35 35 IL70 20 CONDUCTOR SCHEDULE KEY 1 CONDUCTORS 1 CU/AL 1 TYPE LOCATION 1 TRADE A I-#12 ENPHASE Q CABLE,I-#6G,FREE AIR CU LAR UL3003.DG CABLE ARRAY SO B 3-#10°.I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR 9 C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR O 'NEUTRAL CAPPED AND NOT USED M 8 Q 4 Q3 O 5A/F 7 OO 6 0A/2 IOA/1P N —1 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.560KW LOT#29 ORIGINAL BY:T HAMMERBACHER I DATE:IB.OI.I6 HERITAGE HEIGHTS LENNAR: 980 REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17 CORONNA,A.C LA A 92 DRIVE,#302 879 REV.# BY DATE DESCRIPTION Pniamasbi§ IOLAP DWG TITLE: PAGE It: SCALE: SITE LOCATION: 67079Wnchesler Circle INDIVIDUAL 29100 REDWOOD STREET Suite 700 PLOT PLAN 2 NTS MENIFEE,CA BOultler.CO B0307 ELECTRICAL 1 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 'raRT� 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH Q1 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND f� THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. rderal, plans mt ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSl92E'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90'C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT P. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:T HAMMERBACHER I DATE18.01.16 LENNPR: HERITAGE HEIGHTS REVIEWED BY:OESIREE WILLIAMS I DATE18.01.17 980 MONTECITO DRIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION 2pniamasui DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 VSuite7 0 CllGe INDIVIDUAL MENI REDWOOD STREET Suite O8 PLOT PLAN 3 NTS MENIFEE.CA Boulder, NOTES 303.41].0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 3n ty :;4t on the SOLADECR WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE LZUTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.36A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:T HAMMERBACHER ]DATE i8.01.16 HERITAGE HEIGHTS LENNAR: REVIEWED BY:DESIREE WILLIAMS DATE18.01.17 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.* BY DATE DESCRIPTION namasG6 sous DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707VdnclIester Circle INDIVIDUAL 29100 REDWOOD STREET Suite 700 PLOT PLAN 4 NTS MENIFEE,CA Boulder,CO 80301 PLACARDS 303.447.0300