PMT18-02000 City of Menifee Permit No.: PMT18-02000 29714 HAUN RD. '!CCELAI MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 05/04/2018 PERMIT Site Address: 29128 REDWOOD ST, MENIFEE,CA Parcel Number: 92584 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 1 INVERTER,2.240 kW LOT 27 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtty Amount fE1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors In the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Mantles.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permil_Templatexpt Page 1 of 1 BUILDING,,&SAFETY P.ER„MIT[PLAN CHECK APPLICATION, MENIFEE o — T DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER 110�VO`w PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129 Plan No. 1-7 ff c?/ a,a* kW/ —1 PCS PROJECTADDRESS 29128 Redwood St zip 92584 ASSESSOR'S PARCEL NUMBER LOT 27 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNERBUILDER? OYES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 p EMAIL samantha.mazeila@lennar.com CONTRACTOR'S STATE LIC NUMBER �10 ZDa LICENSE CLASSIFICATION IVA VALUATION$ $5,613.76 SSSo FT L SQ FT APPLICANT'S SIGNATURE �;)/Y(lY J'�'' DATE DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ' —^ INVOICETOTAL a613, (00 GREEN SMIP OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.cityofmenifee.us AVIAMEM !11 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLINR MODULES TO BE INSTALLED ITEM I OTY I MFR. MODEL ON THE ROOF OF THE HOME WILL BE fUBSCNA( LYNJrTNEiCNIFE SYSTEM SIZE 2.240.KW LOCATIONS INDICATED BY THE ILLUS TI�OryN LLff E MODULE 7 PCS.1 LG I LG320EIK-A5(320W) BUYER: )Iti Ill►If• ♦•sD •7 C INVERTER 7PCS. ENPHASE ID6PLUS-72-AGM-US WE ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION PROM L ARRAY#I 1 ARRAY#2 1 ARRAY#3 ARRAY#4 MOD OTY 7I NA NA NA BUYER: TILT 23' NA' NA' NA' AZIMUTH 271• 1 NA* I NA' NA. City of Menif DATE: Building Dept. APR 2 1 NI-3 it `Approval of these plans shall r of be o approval of,any violation of an provis ReceiReceived regulations and ordinances. Thl set of ved jobsite until completion. 5'-6' 3" N t9 N }Z �y2 G j LL F J�':. � NN ORANSITIO WIRE f TRANSITION BOX O (UNDER ARRAY) / PV AC DISCONNECT [ ' EXTERIOR-GARAGE �•/ UTILITY METER IS MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX « NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF A I PLAN 1782 ELEVATION C ENH-LEFT I®V ORIENTATION I LOT#27 ORIGINAL BY:T HAMMERBACHER DATE:IB.OLIfi HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17 CORONA.CA 92879 REV.# BY DATE DESCRIPTION ;Rmarnaai DWG TITLE: PAGE#: I SCALE: sauc SITE LOCATION: 6707 VSuite 7 0 CirNa INDIVIDUAL MENI RE.CA STREET der, OB PLOT PLAN I/16'=I'-0' MENIFEE.CA Boulder,CO300 SYSTEM LAYOUT 303.44].0300 ELECTRICAL EQUIPMENT SCHEDULE -- KEY CITY MANUFACTURER MODEL NOTES TRADE I 7 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-0US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR ' DEI 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IGAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINERBOX SOLAR 6 ENPHASE TBD PV BREAKER, X 20A-2P,I X 5A-2P SOLAR 7 I CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR 8 I TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER,]PH,1201240V.200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE.UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER rued tL TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C. -2 MAIN DISCONNECT AMPS 200 Of the TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40 ;Cued TEMP,DELTA LOW(TDELTA) THIN-TTEBT •C -27 PV OCPD DEVICE USED AMPS 20 P MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 1.17A x 7(MODS)= 8.19A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 B.19A x 1.25- 10.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT QAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD. QTY BC OTY 7 BRANCH CIRCUIT OUTPUT,IHA,XBC (IAC-MOD.QTY Bc) AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD. OTY T OTY 7 TOTAL SYSTEM OUTPUT IMAXTS MAC MOD. CITY T) AMPS(AC) 1 8.19 CONDUCTOR SIZING CALCULATIONS L CONDITION AF USE(COLD: (AMPACITY-TEMP.DERATE ' FILL DERATE)VS.REG'D(TMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS. REWD,(TMAX' 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 =.7611..O22.80 8.19 TERM 2525 10.24 t2o ] B #10 CU NM-B COU 40 36.40 8.19 TERM 3535 10.24 C #10 CU NM-B COU 40 36.40 8.19 TERM 3535 10.24 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENPHASE Q CABLE.I-#6G,FREE AIR CU UL3003.DG CABLE I ARRAY I SOLAR B 1 3-#10',1-#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 9 C 1 3-#10.1-#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 'NEUTRAL CAPPED AND NOT USED O- B 4 m O OSA/F O I Q 6 malt 2 I(_ i. DA/1P 4 T —_- IN A B C C =10 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#27 ORIGINAL BY:T HAMMERBACHER I DATE:IB.OI.I6 HERITAGE HEIGHTS LENNAR: REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17 CORONA. NA.CA 92 DRIVE.#302 CORONA,CA 92B79 REV.# BY GATE DESCRIPTION namasGd soxAv DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 VNncllester Circle INDIVIDUAL Z9128 REDWOOD STREET Suite 700 PLOT PLAN 2 NTS MENIFEE,CA Boulder.CO M01 ELECTRICAL 303.447.030D INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING.WILL BE SEALED WITH AN APPROVED SEALANT. 1 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. TMEN 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH Q')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES w)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. / 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. B PBrtedh TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. I' E 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ust be k ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEL. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED.SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE LY_1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. ID)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:T HAMMERBACHER DATE18.01.16 HERITAGE HEIGHTS LENNAR: REVIEWED BY:DESIREE WILLIAMS I DATE18.01.17 980 MONTECITO DRIVE,#302 REV.# BY DATE DESCRIPTION •, CORONA,CA 92879 namaSOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: roue INDIVIDUAL 6707 VSuIte7OO Circle PLOT PLAN 3 NTS MENI REDWOOD STREET Se11e OB NOTES MENIFEE.CA BONBeA 7.0300 7 300.447.0300 CAUTION POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. J an 7 on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BO% SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION HERITAGE HEIGHTS LENNAR: ORIGINAL BY:T HAMMERBACHER DATEf8.01.16 REVIEWED BY:DESIREE WILLIAMS DATE18.01.17 CO NA.CA I92 DRIVE.#302 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION titmasbe DWG TITLE: PAGE#: SCALE: SITE LOCATION: SOLARINDIVIDUAL 6]07 N1uite 700 Circle PLOT PLAN 4 NITS2912E REDWOOD STREET Site O8 0301 PLACARDS MENIfEE,CA Ba301 7OWO 303.447.0300