Loading...
PMT18-01999 City of Menifee Permit No.: PMT18-01999 29714 HAUN RD. Type: Residential Electrical ''�CCEL/17. MENIFEE,CA 92586 MENIFEE Date Issued: 0 5/0 412 01 8 PERMIT Site Address: 29142 REDWOOD ST, MENIFEE, CA Parcel Number: 92584 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 1 INVERTER,2.240 kW LOT 26 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Qty, Amount f$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Peunit_Template.rpt Page 1 of 1 B,UI,LDING &SAFETY PERMIT.P N EC APpL CATION , AUL-_ MENLFcc & - 1 S ETY DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER ' PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOUSPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O.NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129 Plan No. 1$-I / SL,aqb kW/ PCS PROJECTADDRESS 29142 Redwood St zip 92584 ASSESSOR'S PARCEL NUMBER LOT 26 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ $5,613.76 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE y 11�I ll DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICETOTAL I .Le0 1 GREEN � SMIP � OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777 www.c ityofm e n ifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM DTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE _. SYSTEM SIZE 2.240 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 7 PCS.1 LG I LG320EIK-A5(320W) BUYER: IyLLI OF MEN INVERTER 1 7 PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: —fWtLDIN �t SUB-ARRAY INFORMATION ARRAY#1 1 ARRAY#2 ARRAY#3 ARRAY#4 PLAN A PRC MOD OTY 7 NA NA NA BUYER: TILT I is. NA- I NA' NA' City Of Mende DATE: 111< AZIMUTH 271° NA' NA' NA° Building Dep REVIEW APR 2 7 'U,.3 Received 'Approval ofth neplal approval of,an I violad regulations and or&w 6•-6• 3• jobsite until co npklo rz - J N� Q_-1 SOLADECK II TRANSITION WIRE N BOX (WIDER ARRAY) t PV AC DISCONNECT EXTERIOR-GARAGE UTILITYSEEM METER L e O MIN RIF SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX �' 4r NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 1874 ELEVATION B ENH-LEFT ORIENTATION I LOT#26 ORIGINAL BY:T HAMMERBACHER DATE:IB.OI.I6 HERITAGE HEIGHTS LENNAR: 980 REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17 CORONNA.A.C CA A 92879 DRIVE.#302 REV.# BY DATE DESCRIPTION namasGE souv DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6]0]WSW 700 Circe INDIVIDUAL 29142 REDWOOD STREET SWIe O,8 PLOT PLAN I/16':I'-0' MENIFEE,CA Ba303A C080307 SYSTEM LAYOUT 303.447.030D ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES TRADE 1 7 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR EE 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR �� 4 1 ENPHASE 10 ENVOY ENV-IOAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD. PV BREAKER, IX 2OA-2P.1 X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR B I TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER.IPH,120/24OV.200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. I(A AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATION ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(THAX) ASHRAE 2% •C 37 BUS RATING AMPS 200 I of be a TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC PC 25 ALLOWED PV PER NEC AMPS 40 ( n provis TEMP,DELTA LOW(TDELTA) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: •• h S set 01 MOD.PART NUMBER AC MODULE SPEC LG320EIK-AS(32OW) 1.17A x 7(MODS)= 8.I9A OF CURRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(134) 320 B.19A x 1.35= 10.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT OAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC H7(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC QTY 7 BRANCH CI DURCUIT OUTPUT,IMAXBC (14['MOD.OTY BC) AMPS(AC) 8.19 AC MOLE QUANTITY,TOTAL MOD.QTY T QTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC-MOO.OTY T) AMPS(AC) 8.19 CONDUCTOR SIZING CALCULATIONS O CONDITION OF USE(COU): (AMPACITY• TEMP.DERATE -FILL DERATE)VG.REOID(IHAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REQ'D,(IMAX• 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/13 TEMP. FILL RESULT REQ'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A Z#12CUTHWN-2 LOU 30 .7622.80 8.19 TERM 25 25 10.24 20 B NM-B COU 40 .91 L0 36.40 8.19TERM 35 35 10.24 20 C NM-8 COU 40 .91 L0 56.40 8.19 TERM 35 35 10.24 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE q I-#12 ENPHASE 0 CABLE, 1-#6G,FREE AIR CU I UL3003.UG CABLE ARRAY I SOLAR B 3-mv.1-#10 EGC I CU I NM-B(RDMEX) I INTERIOR I SOLAR 9 C 3-#10.1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 'NEUTRAL CAPPED AND NOT USED O— 0 IB 4 m 3 0 ura TTITO O Ar 2o 4O 6 20A/2 'N I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#26 LENNAR: ORIGINAL BY:T HAMMERBACHER DATE:18.01.16 HERITAGE HEIGHTS REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17 CORONA. NA.CA I92 DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namaste xorwe DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707Wn&ester CirUe INDIVIDUAL 29142 REDWOOD STREET Suite 70D PLOT PLAN 2 NTS MENIFEE,CA Boulder.CO 80301 ELECTRICAL 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- 0 ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. , EPA 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL Z016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(g)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(0 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. {,. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. Ied Iw 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. r the fed ii ved plan ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEL. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL HE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES, 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:T HAMMERBACHER DATEI8.OI. LENNAR: Ib HERITAGE HEIGHTS REVIEWED BY:DESIREE WILLIAMS I DATE18.01.17 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Oniamasbd soLAe DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 6707 Winchester Circe 700 PLOT PLAN 3 NTS MENU REDWOOD STREET SUBSO8 NOTES MENIFEE.CA Bo30140080301 303.407.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE -MENT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. cit for,or WE or ci at be kept o i the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION HERITAGE HEIGHTS ORIGINAL BY:T HAMMERBACHER DATEi8.01. 980 MONTECITO DRIVE,#302 16 IAR: REVIEWED BY:DESIREE WILLIAMS DATE18.01.I7 80 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, namasb6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 8707 VSuite 7 D Circle INDIVIDUAL MENI REDWOOD STREET Suite O8 PLOT PLAN 4 NITS MENIFEE,CA Boulder,C080301 PLACARDS 303.447.0300