Loading...
PMT18-01998 City of Menifee Permit No.: PMT18-01998 29714 HAUN RD. Type: Residential Electrical <ACCEL/? MENIFEE, CA 92586 MENIFEE Date Issued: 0 510 412 01 8 PERMIT Site Address: 29156 REDWOOD ST,MENIFEE,CA Parcel Number: 92584 Construction Cost: $5.613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 1 INVERTER,2.240 kW LOT 25 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtv Amount(El Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 I BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION.- lF DATE: 4/19/2018 PERMIT/PLAN CHECK NUMBER t io -{6 PLANNING CASE NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Heritage Heights - Solar Permit- Master Permit No: PMT 17-00129 PlanNo.178a/ a. 600 kW/ `] PCS PROIECTADDRE55 29156 Redwood St zip 92584 ASSESSOR'S PARCEL NUMBER LOT 25 TRACT 31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella lennar.com APPLICANT NAME Lennar Homes of California Inc. ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES O NO BUSINESS NAME ADDRESS 980 Montecito Dr. Ste 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER �7b��fly8 LICENSE CLASSIFICATION A' S VALUATION$ $5,613.76 SOFT LSoFT pI APPLICANT'S SIGNATURE U ' v DATE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: ^]�,�_ _ CITY OF MENIFEE BUSINESS UCENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I � 1 INVOICETOTAL �.f/V GREEN l SMIP ( �. OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE ti NOTARIZED LETTER O YES O NO City of Menifee Building &Safety Department 129714 Haun Rd., Menifee, CA 92586(951)672-6777 www.c ityofm en ifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. I MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIA;hYI PI((E MENI EE SYSTEM SIZE 2.240KW LOCATIONS INDICATED BY THE ILLUSTRATION. /�MODULE 7PCS. LG LG320EIK-A5(320V0 BUYER: I°s 0110 AN Qe INVERTER 7PCS. ENPHASE 106PLUS-72-AGM-US vn ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: RO � SUB-ARRAY INFORMATION L, ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 7 NA NA NA City of Menifee BUYER: TILT 23° NA' I NA' I NA- Building Dept. DATE: AZIMUTH 271° NA- I NA- I NA- APR 2 7 2Uj i `rproval of'hose plans hall no Received approvalo) Violation of any I reg111390:,' j ordinance , This jolulte ull'. completion. 5'-6' 3' -- >z a� �LL w (V� IL, SOLADECK WIRE �'I \ TRANSITION BOX U. (UNDER ARRAY) f1 PV AC DISCONNECT EXTERIOR-GARAGE - UTILITY METER e Q, MAIN SERVICE PANEL (VERIFIED BY BUILDER) AL COMBINER BOX LW NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 1782 ELEVATION A ENH-LEFT ORIENTATION I LOT#25 ORIGINAL BY:T HAMMERBACHER DATE:18.01.16 HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS I DATE:18.01.17 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION ;Pniamast;6 souv DWG TITLE:. PAGE#: I SCALE: SITE LOCATION: 8]0]NSUMe70 ClNe INDIVIDUAL MENI REDWOOD STREET e.CO8 PLOT PLAN /Ib'=I'-0' MENIFEE.CA Flout 1"7.03W SYSTEM LAYOUT sos.a].osoo ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 7 LG LG320EIK-A5(320W) ACPV MODULE W/ INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR DE 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V,30A SOLAR 4 1 ENPHASE IQ ENVOY ENV-ICIAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 2OA-2P.I X 5A-ZP SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL,200A BUS BLOR.ELEC. 9 1 TBD TBD UTILITY METER,[PH,120/24OV,200A BLOR.ELEC. 10 I TBD TOD GROUNDING ELECTRODE,UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/LALC UNIT DETAIL ITEM UNIT I PANEL .0 istrued LOCATION MENIFEE,CA PANEL MFR. I CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 200 Ili ns of# TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 Proves TEMP,DELTA LOW(TOELTA) THIN-TTEST ^C -27 PV OCPD DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC _G320EIK-A5(32OW) 1.17A X 7(MODS)- 8.19A OF QIRRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 8.19A X 1.25= 10.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A MA12P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/21I-264 NOMINAL OUTPUT CURRENT(IA6) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY Bc CITY 7 BRANCH CIRCUIT OUTPUT, IM"BC 0AC'MOD.QTY BC) AMPS(AU 8.19 AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD.QTY T) AMPS(AC) 1 8.19 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COLD: (AMPACITY'TEMP.DERATE-FILL DERATE)9s.REWD(IHAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.9S.REO'D,(IHAX• 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'O OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 .76 I.0 22,80 8.19 TERM 25 25 10.24 20 B 010 CU NM-B COU 40 .91 1.0 36.40 8.19 TERM 35 35 10.24 20 C #10 CU NM-B COU 40 .91 1.0 36.40 8.19 TERM 35 35 10.24 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-7t12 ENPHASE Q CABLE,1466,FREE AIR I CU UL3003,DG CABLE ARRAY I SOLAR B 1 3-910•. -#10 EGC I Cu I NM-B(ROMEX) I INTERIOR I SOLAR 9 L 13410.1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O 'NEUTRAL CAPPED AND NOT USED M B O 4 Q3 S F O I O ICHR0 6 L ea x x9e1xP 'N 6 G� A B c c 10 1 1 1 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#25 ORIGINAL BY:T HAMMERBACHER DI HERITAGE HEIGHTS LENNAR: 980 I DRIVE,#302 REVIEWED BY:DESIREE WILLIAMS DATE:18.01.17 CORONA,A,C CA NA 92879 REV.# BY GATE DESCRIPTION namast8 same DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 67W VSdite7 0 Cirtle PLOT PLAN 2 NTS MENIF REDWOOD Suite O8 ELECTRICAL MENIFEE,CA �303�C0300 INSTALLATION NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. RTM! 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A:ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40% 9)AN ANIMAL GUARD SMALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE h �� TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. ,I__ Sta TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. , I,14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. '( S must b BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k, 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:T HAMMERBACHER DATEI8.01.16 HERITAGE HEIGHTS LENNAR: REVIEWED BY:DESIREE WILLIAMS I DATE18.01.17 980 MONTECITO DRIVE.4302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasGifi soiwe DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 6707 Wiuite70 rCim)e PLOT PLAN 3 NTS MENIF REDWOOD STREET Suite NOTES MENIFEE,CA Bouldw,C030301 303.g47.0300 CAUTION: it POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. or an ilfy :t on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:T HAMMERBACHER DATE111.01.16 HERITAGE HEIGHTS LENNAR: REVIEWED BY:DESIREE WILLIAMS DATE18.01.17 980 NA,CA 92 DRIVE.#302 CORONA,CA 92B79 REV.# BY DATE DESCRIPTION -is namast§ soux DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 W,uite 7 0 Circe INDIVIDUAL MENI REDWOOD STREET Boulder, O8 PLOT PLAN 4 NTS MENIFEE,CA Bo303.4 7080001 PLACARDS 303.447.0300