PMT18-01947 City of Menifee Permit No.: PMT18-01947 29714 HAUN RD. �CCELA7 MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 05/01/2018 PERMIT Site Address: 24558 HIDDEN HILLS DR, MENIFEE,CA Parcel Number: 358-661-009 92584 Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR, 9 PANELS,9 MICROINVERTERS,2.880 KW Work: DAKOTA TR 32025 LOT 34 Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET,STE 250 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone: 3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description 0tv Amount l5l Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after Issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_8Idg_Perm1t Template.rpt Page 1 of 1 i B APPLICATION ..,... DATE 04/1 912 01 8 PERMIT/PLAN CHECK NUMBER Q°° ;-W6705 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN SUBTYPE: []ADDITION ❑ALTERATION [-]DEMOLITION QELECTRQ*Eg4"4RIQICAL El NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES Building Dept. DESCRIPTION OF WORK INSTALL 2.88OkW ROOF MOUNTED PV SYSTEM APR 7 4 2018 PROJECT ADDRESS 24558 HIDDEN HILLS DRIVE,MENIFEE, CA Received ASSESSOR'S PARCEL NUMBER 358-661-009 LOT 34 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑✓ NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $7.626.00 SO FT L SO FT APPLICANT'S SIGNATURE C/1."tm DATE 04/19/2018 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN — SMIP I INVOICE My� PAIDAMOUNT AMOUNT • ►�/�/ OCASH 0 CHECK k OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH C CHECK A O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED 0 YES 0 NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM S1ZE 2.88OKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS.1 LG I LG320EIK-A5(320W) BUYER: INVERTER 9 PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE I CONIC.TILE DATE: SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 5 4 NA NA BUYER: TILT 23° 23° 1 NA' NA. AZIMUTH 175° 1 175• 1 NA' I NA° City of Menifee DATE: ---- Building Dept. APR 2 4 2018 Received X 4' 10'-1' 13'-5'ARRAY 4' NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) 'o N �^ CITY OF MEN FE PV E DISCONNECT BUILDING A D E EXTERIOR-GARAGE UTILITY METER B pLAN APPR AI MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX REVIEWED B 'Approval of these plan shal approval of,any violatio I of a regulations and ordinanc as. T NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF Jobsite until Wpletion PLAN 3X ELEVATION C-RIGHT ORIENTATION I LOT#34 ORIGINAL BY:DAN BOWLING I DATE:18.04.17 DAKOTA AT WOODSIDE HOMES: 1187E PIERCE STREET.SUITE#100 REVIEWED BY:T.HAMMERBACHER I DATE:I6.04.I8 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION b namaste sntev DWG TITLE: PAGE #'. SCALE: SITE LOCATION: t. 6707 Winchester Circle INDIVIDUAL 24558 HIDDEN HILLS DRIVE Sude 700 PLOT PLAN 1 1716'=1'-0* MENIFEE,CA B0 er,C080301 SYSTEM LAYOUT 30.i.4g7.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY CITY MANUFACTURER MODEL NOTES TRADE 1 9 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 2 TBD TBD PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG22IURS PV AC DISCONNECT,NEMA 3R, 240V.30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER.I X 2OA-2P,I X SA-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TSD UTILITY METER,IPH, 120/24OV,200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 38 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 1 200 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 1 40 TEMP,DELTA LOW(TDLLTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(32OW) 1.17A x 9(MODS)° 10.53A OF CURRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(DD) 320 Io.53A x I.25= 13.I5A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN wITN A 2BArZP Z sPADI"Pv BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY ec OTY 9 BRANCH CIRCUIT OUTPUT.IMAXBC 0AC'MOD.QTY 8C) AMPS(AC) 10.53 AC MODULE QUANTITY,TOTAL MOD.OTY T QTY 9 TOTAL SYSTEM OUTPUT IMAXTS (IAC-MOD.OTY T) AMPS(AC) 10.53 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COLD: (AMPACITY' TEMP. DERATE' FILL DEBATE)vs. REO'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS.REO'D,(IMAX- 1.25) KEY SIZE CU/AL INSULATION CALL' AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 0.76 1.0 22.130 10.53 TERM 25 25 13.16 20 B #10 CU NM-B COU 40 0,91 1.0 36.40 10.53 TERM 35 35 13.16 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 20 CONDUCTOR SCHEDULE KEY IS CU/AL TYPE LOCATION TRADE Q p -#12 ENPHASE 0 CABLE,1-#6G,FREE AIR CU UL3003.DG CABLE ARRAY SOLAR 9 B 3-#10',I-#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR C 3-#10.1-#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR M ^ETY DEI 'NEUTRAL CAPPED AND NOT USED 8 O 4 O G 5A/2P O © t0Al2 20A/2 N G G G L.P.con trued A B C C _ 10 �`-o of tt of ap rove( I I ( ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.88OKW. LOT#34 ORIGINAL BY:DAN BOWLING OATE:18.04.17 DAKDTA AT WOODSIDE HOMES: 11870 PIERCE STREET,SUITE#100 REVIEWED BY:T.HAMMERBACHER OATE:18.04.18 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION t-:1namast;6 ]OIAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 8707 Winchester Circle INDIVIDUAL 24558 HIDDEN HILLS DRIVE Suite 700 PLOT PLAN 2 NTS MENIFEE.CA Boulder,CO SD301 ELECTRICAL 303."7.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PY PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 11)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- ])ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED.ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS, 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)M�MIHEIGHT PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERINGMIN r. �F� EN 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. �(( BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. 11 �1 I e a perrit for, 'eral,i late or is mu be kq ORIGINAL BY:DAN BOWLING DATE18.04.17 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER I DATE18.04.18 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION t1masud SOr/.R DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circa INDIVIDUAL 24558 HIDDEN HILLS DRIVE Suite700 P O8 PLOT PLAN 3 NTS MENIFEE.CA Boulder.C060001 303.NOTES 947.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER A MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE — AC SPECS A PHOTOVOLTAIC SYSTEM EQUIPPED C OPERATING VOLTAGE: 240 V E AC OPERATING CURRENT: 10.53A WITH RAPID SHUTDOWN n I PC., NEC 690.54 1 PC., NEC 690.12 ' n the NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING DATE18.04.17 11870 PIERCE STREET.SUITE#100 DAKOTA AT WOODPIIE HOMES: REVIEWED BY:T.HAMMERBACHER I DATEi8.04.18 AUDIE MURPHY RIVERSIDE.CA 92505 REV.# BY DATE DESCRIPTION b namast6 —1 s fMAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 VAMe 700 Circe INDIVIDUAL 24550 HIDDEN HILLS DRIVE O8 PLOT PLAN 4 NTS MENIFEE,CA Boulder,CO80301 303. PLACARDS 303.447.0300