Loading...
PMT18-01945 City of Menifee Permit No.: PMT18-01946 29714 HAUN RD. <A-CCELA—>. MENIFEE,CA 92586 Type: Residential Electrical ""`'""" MENIFEE Date Issued: 05/01/2018 PERMIT Site Address: 24553 HIDDEN HILLS DR, MENIFEE,CA Parcel Number: 358-660-024 92584 Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR,9 PANELS,9 MICROINVERTERS,2.880 KW Work: DAKOTA TR 32025 LOT 24 Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET, STE 250 760 NORTHWEST 107 AVENUE RIVERSIDE,CA 92505 MIAMI, FL 33172 Applicant Phone: 3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description gtv Amount t5l Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Perm@_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION w ..'Menifee q DATE 04/19/2018 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL [Z]RESIDENTIAL MULTI-FAMILY ❑MOBILEHOME POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION QELECTRICALQbfM®„)f@Q ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES---Builrling Dept. DESCRIPTION OF WORK INSTALL 2.880kW ROOF MOUNTED PV SYSTEM PROJECT ADDRESS 24553 HIDDEN HILLS DRIVE,MENI FEE, CA Received ASSESSOR'S PARCEL NUMBER 358-660-024 LOT 24 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)4505840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑✓NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $7,626.00 SO FT L SO FT APPLICANT'S SIGNATURE t . -t-' �,�/�-AZLL�_� DATE 04/19/2018 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAIDAMOUNT /]] �y� AMOUNT �w G;q� -Lo `0CASH >CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Noun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITY MFR. I MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.880 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS. LG LG320EIK-AS(320W) BUYER: INVERTER 1 9 PCS.1 ENPHASE I 06PLUS-72-ACM-US ROOF TYPE I CONC.TILE DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 TIOLTCITM IB' NA' NA' N 1 NA NANnA' City of Menifee BUYER: AZIMUTH 1 181' NA' NA' NA' Building Dept' I DATE: —_ APR 2 4 2018 Received O in 2'-%* 16'-9'ARRAY NEMA 3R JUNCTION BOX (I' OUTSIDE ARRAY) CITY OF MENIF E BUILDING AND AI PV AC DISCONNECT EXTERIOR-GARAGE PLAN APPROV L UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) � _. REVIEWED BY AC COMBINER BOX 'Approval of these plans sh II not approval of,any violation of my p, regulations and ordinances. 'hiss Johsite until completion. NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 4 ELEVATION C-LEFT ORIENTATION 3 LOT#24 ORIGINAL BY:DAN BOWLING DATE:I8.04.I7 DAKOTA AT WOODSIDE HOMES: 11870 PIERCE STREET.SUITE#100 REVIEWED BY:T.HAMMERBACHER DATE:I8.O4.I8 AUDIE MURPHY RIVERSIDE.CA92505 REV.# BY DATE DESCRIPTION .i� namast;6 sotee DWG TITLE: PAGE #: SCALE: SITE LOCATION: INDIVIDUAL 6]0]Winchester Circle 24553 HIDDEN HILLS DRIVE Suite 700 O8 PLOT PLAN I I/16'= I'-0' MENIFEE.CA Boultler,C080301 SYSTEM LAYOUT 1 303,447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 9 1 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE IQ6PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 TBD TBD PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URET PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 4 1 ENPHASE lO ENVOY ENVAGAMI-20 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI-240-.B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 2OA-2P, I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL,200A BUS BLOR.ELEC. 9 1 TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC. 10 1 TBD I TBD I GROUNDING ELECTRODE,UFER I BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 38 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP.DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: ° MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 117A x 9(MOM)= 10.53A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 10.53A x 1.25- 13.16A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 2DA/2P 2 BPACE PV BAMFEED BRIMER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY 7 RANGE AC MODULE SPEC H2(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 /IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD. QTY Bc CITY 9 BRANCH CIRCUIT OUTPUT, IMAXec (IAC•MOD.QTY Be) AMPS(AC) 10.53 AC MODULE QUANTITY,TOTAL MOD, QTY T OTY 9(AC) 1 TOTAL SYSTEM OUTPUT IMAxTs (IAC'MOD.QTY T) AMPS0.53 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATE= FILL DERATE)vs. REWD(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REO'D,(IMAx• 1,25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT I REO'D OCD TYPE DERATES DERATE I DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.53 TERM 25 25 13.16 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 10.55 TERM 35 122 13.16 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 1 35 13.16 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE I LOCATION TRADE O9 A -#12 ENPHASE 0 CABLE, 1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR TY DEB B 3-#10•. -#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR O L 3-#10.1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 'NEUTRAL CAPPED AND NOT USED O 8 0 4 0 O sazP O O 6 2oA/z z 20A/2 �N G G lOnstri ed to G inns c f the f A e C C = to fappro edpli I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.88OKW LOT#24 ORIGINAL BY:DAN BOWLING I DATE:18.04.17 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER I DATE:18.04.18 11870 PIERCE STREET.SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION - � namastAR SOLA0. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circe INDIVIDUAL 24553 HIDDEN HILLS DRIVE Suite 700 PLOT PLAN 2 NTS MENIFEE,CA Boulder,CO 80301 ELECTRICAL 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH G�)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, IU ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- .AT EN7 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT''. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. a nem It forte a!,st ite or c 'nust ie kept 11870 PIERCE STREET.SUITE#100 ORIGINAL BY:DAN BOWLING DATE/8.04.17 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER DATE18.04.I8 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION �2amast;6 SOU. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 NAncheeter Circle INDIVIDUAL 24553 HIDDEN HILLS DRIVE Suite700 PLOT PLAN 3 NTS MENIFEE,CA Boulder,CO 8D301 NOTES I 303.447.03DO CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BOX (I' OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER 80X SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR TE n PV POWER SOURCE — AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED the AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 10.53A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING I DATE18.04.17 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER I DATE18.04.18 11870 PIERCE STREET.SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namasae eotee DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707Vdno ter Circle INDIVIDUAL 24553 HIDDEN HILLS DRIVE Suite 700 PLOT PLAN 4 NTS MENIFEE.CA Boulder,CO 80301 PLACARDS 303.447.0300