Loading...
PMT18-01941 City of Menifee Permit No.: PMT18-01941 29714 HAUN RD. �CCEL^'J MENIFEE,CA 92586 Type: Residential Electrical $".. MENIFEE Date Issued: 05/01/2018 PERMIT Site Address: 24570 HIDDEN HILLS DR, MENIFEE, CA Parcel Number: 358-661-008 92584 Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR,9 PANELS,9 MICROINVERTERS,2.880 KW Work: DAKOTA TR 32025 LOT 33 Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET, STE 250 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description ON Amount I$) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING : APPLICATION 4y, '''Menifee N DATE 04/19/2018 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION ❑✓ ELECTRICAL []MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES City of Menifee DESCRIPTION OF WORK INSTALL 2.88OkW ROOF MOUNTED PV SYSTEM APR 2 4 2018 PROJECTADDRESS 24570 HIDDEN HILLS DRIVE,MENIFEE,CA ' ASSESSOR'S PARCEL NUMBER 358-661-008 LOT 33 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)4505840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑✓NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $7,626.00 SO FT L SO FT APPLICANT'S SIGNATURE '\ DATE 04/19/2018 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN 1' SMIP INVOICE PAID AMOUNT AMOUNT ,IM WWVV OCASH OCHECKp OCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECKA 0CREDIT CARD VISAIMC OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM QTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.88OKW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS.1 LG I LG320EIK-A5(32OW) BUYER: INVERTER 1 9 PCS1 ENPHASE I IQ6PLUS-72-ACM-US ROOF TYPE I CONIC.TILE DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 MOD QTY 9 NA NA NA BUYER: - - TILT IF NA° NA° NA° AZIMUTH 1 170° NA° I NA* NA° DATE: ------ City of Menifee Building Dept. APR 2 4 2018 Received T 5'-11' 30'-2'ARRAY �n 0 in NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) CITY OF ME NIF PV AC DISCONNECT BUILDING ND EXTERIOR-GARAGE UTILITY METER 6 PLAN APPR,0V All MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX F..E`.'I WED Bi 'dpprovzl of these lam 1 i approval Df,any vi alion requla!ions and ord nance NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF 1'JAE(Nil compl Lion, I PLAN A ELEVATION A-RIGHT ORIENTATION I LOT#33 DAKOTA AT WOODSIDE HOMES: ORIGINAL BY:DAN BOWLING DATE:I8.04.I6 11870 PIERCE STREET,SUITE#100 REVIEWED BY:T.HAMMERBACHER I DATEA8.04.17 h AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION _ namasbe souv DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 67W Winchester Circle 24570 HIDDEN HILLS DRIVE Suite O PLOT PLAN I /Ib'= I'-0' MENIFEE,CA BONae0301 SYSTEM LAYOUT 303,4 703 847.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 9 LG LG320EIK-A5(320W) ACPV MODULE W/ INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 TBO TBD PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.240V.30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER, I X 20A-2P.I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER,IPH.120/24OV,200A BLDR.ELEC. 10 I TBD I TBD I GROUNDING ELECTRODE,UFER I BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(THAx) ASHRAE 2% •C 38 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 20D TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) Timm-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(32OW) I.I7A x•(MODS)= 10.53A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DO) 320 I0.53A x 1.25= I3.I6A. PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREMER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAO) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/ IEEES47 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY Bc OTY 9 BRANCH CIRCUIT OUTPUT, IMAXBC (IAC'MOD.QTY 6c) AMPS(AC) 10.53 AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 1 9 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD.OTY T) AMPS(AC) 10.53 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY-TEMP.DERATE- FILL DERATE)Vs.REO'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.Vs. REO'D,(IMAx- 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 0.76 1 1.0 22.80 10.53 TERM 25 1 25 13.16 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 20 ( #10 1 CU I NM-B COU 40 0.91 1 1.0 36.40 10.53 TERM 35 35 13.16 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL 1 TYPE 1 LOCATION 1 TRADE A L#12 ENPHASE 0 CABLE, 1-#6G,FREE AIR CU UL3003,OG CABLE ARRAY SOLAR 9 2- g 3-#10'.I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C C 1 3-#10, I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O t MF'NEUTRAL CAPPED AND NOT USED 5 O 4 3Q O 5A/2P 7 O 2OP O 6 20Al2 C G ■ G G �N A e c C =ID not be c sh9 y proviss ons a ROOF EXTERIOR-GARAGE 5is set of ippm ELECTRICAL DIAGRAM 2.88OKW LOT#33 ORIGINAL BY:DAN BOWLING I DATE:18.04.16 WOODSIDE HOMES: DAKOTA AT REVIEWED BY:T.HAMMERBACHER I DATE:18.04.17 11870 PIERCE STREET.SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION •� namasbe IOIAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VSuke 00 Circle INDIVIDUAL 24570 HIDDEN HILLS DRIVE der, O8 PLOT PLAN 2 NTS MENIFEE,CA B0Nee4 7080307 ELECTRICAL 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(P)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 11)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY E ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.16)ALL p�SAFETY 17)MARKING/P ACCARDS WILL A BE METAL ORPLAST C WITH ENGRAVED OR MACHRDS SHALL BE PERMANENTLY ATTACHED BY HIINE PRINTED HESIVE OR OLETTERINGTHER H AICKGROUNDCAL SWILL BE RED WITH WHITE CAPITAL LETTERIRpq{p EN MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL E COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. be a 1 ermitfa tedera,state r plans n ust be N ORIGINAL BY:DAN BOWLING DATE18qti DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER DATE18 11870 PIERCE STREET.SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION t2inamastd SOSASDWG TITLE: PAGE#: SCALE: SITE LOCATION:INDIVIDUAL CIrGePLOT PLAN 3 NTS 24570 HIDDEN HILLS DRIVE NOTES MENIFEE.CA 03070 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BOX (I' OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE — AC SPECS )AT AC OPERATING VOLTAGE: 240 V PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN xan AC OPERATING CURRENT: 10.53A :Iry con e I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING I DATEi8.04.16 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:T.HAMMERBACHER I DATE18.04.17 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE.CA 92505 REV.# BY DATE I DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 8707 VSukehe 7 0 Circle PLOT PLAN 4 NTS 24570 HIDDEN HILLS DRIVE &Il,CO8 PLACARDS MENIFEE,CA Ba303.4 CO2!00 303.447.0300