PMT18-01697 City of Menifee Permit No.: PMT18-01697
29714 HAUN RD.
'� CCELl47 MENIFEE, CA 92586 Type: Commercial Electrical
MENIFEE Date Issued: 04/25/2018
PERMIT
Site Address: 24867 AUDIE MURPHY RD, MENIFEE, Parcel Number:
CA 92584 Construction Cost: $1,000.00
Existing Use: Proposed Use:
Description of GENERATOR FOR MODELS TR 36485-4 KINGSTON, 125kVA
Work:
Owner Contractor
MERITAGE HOMES SPRINT ELECTRIC INC
17701 COWAN#190 10441 ARLINGTON AVE
IRVINE, CA 92614 RIVERSIDE, CA 92505
Applicant Phone: 9513549520
GRACIANO MARMOLEJO License Number: 747175
10441 ARLINGTON AVE
RIVERSIDE, CA 92505
Fee Description Qtv Amount($)
Power Apparatus 1 183.00
Building Permit Issuance 1 27.00
Additional Plan Review Building 26 25.82
Additional Plan Review Building 129 129.07
GREEN FEE 1 1.00
General Plan Maintenance Fee- Electrical 1 9.15
$375.04
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and o I am exempt from licensure under the Contractor's State License Law for
Professions Code and my license is in full force and effect. the following reason:
License Class C^ D License No. /7 6/2 1 7.5r By my signature below I acknowledge that,except for my personal residence
Expires__3-3/—// Signature ' � in which I must have resided for at least one year prior to completion of
improvements covered by this permit.I cannot legally sell a structure that I
WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by
❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which
www.leQinfo.ca.Rov/calaw.html.
this permit is issued.
Polity# ��c7 L/�� o i ate
PROPERTY OWN R OR AUTHOR ZED AGENT
❑I have and will maintain worker's compensation insurance,as required by
section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property
this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this
number are: application and the information I have provided is correct.I agree to comply
-r f with all applicable city and county ordinances and state laws relating to
Carrier S�ci�C: ��iM 1/0Tit< r L,*,n a building construction.I authorize representatives of this city or county to
Polity 4 !0$�Lj(5-9- --Gd%F Expires %--- enter the above identified property for inspection purposes.
(This section need not to be completed is the permit is for one-hundred Date f
dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT
o I certify that in the performance of the work for which this permit is issued,
I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE q (r/
worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the worker's compensation provisions of Section 3700 of the Labor
Code,I shall forthwithcomply with those provisions. Will the applicant or future building occupant handle hazardous material or a
/ �� iyi 4/—L 5-'�� mixture containing a hazardous material equal to or greater that the
Applicant Date_- /f amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKEl COMPENSATION COVERAGE IS ❑Yes /No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines
CONSTRUCTION LENDING AGENCY ❑Yes 00
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is issued outer boundary of a school?
(Section 3097 Civil Code) o Yes P No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
permitting checklist.I understand my requirements under the State of
I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning
Contractor's License Law for the reason(s)indicated below by the hazardous material reporting.
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5
Business and Professions Code).Any city or county that requires a permit to 0Yk�Y r Date �' /�_/9
construct,alter,improve,demolish or repair any structure,prior to its PR,O�PEE�RTY OWNE OR AUTHORIZE'fQAGENT
issuance,also requires the applicant for the permit to file a signed statement
that he or she is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING(RRP)
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500). managers who do the paint-disturbing work themselves or through their
❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractor's State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because:
o I,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE
, - I
DATE: Y_/'/' g PERMIT/PLAN CHECK NUMBER
PLANNING CASE NUMBER
TYPE: ;; COMMERCIAL /'RESIDENTIAL MULTI-FAMILY MOBILE HOME ':: POOL/SPA SIGN
SUBTYPE: 0"ADDITION ALTERATION DEMOLITION %ELECTRICAL -0 MECHANICAL
_C' NEW�LC: PLUMBING RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK SCTI (y C V,,efC k-3,
PROJECTADDRESS i �, ��] �'7j,t��j � �"t � ZIP
ASSESSOR'S PARCEL NUMBER LOT TRACT 3'2
OWNER NAME `
ADDRESS � no ) U��CAV`" SGvv-k`�- ` �( � � : C g1261V
PHONE rr i , }��°, c1 5 G y 3 3�(� L( EMAIL
APPLICANT NAME h (r� (� GC,r O e, U
ADDRESS 0 I<tiC:7Cif
PHONE S 1-t 4f5"7b EMAIIk I-I(-Ieye c_a
CONTRACTOR'S NAME OWNER BUILDER? YES 0 NO
BUSINESS NAME S //!!
ADDRESS U y� IgEL INC, 1O n, r✓r ;,) CSj - C. l ZS�US_
PHONE j�/ 3 S q 01 Sg"0 EMAIL
CONTRACTOR'S STATE LIC NUMBER 7 1/ 7 7 5 LICENSE CLASSIFICATION
VALUATION $ J,JJ 6 SQ FT L SQ FT
J Q
APPLICANT'S SIGNATURE y '/�CsJ�^ DATE
DEPARTMENT DISTRIBUTION ACCEPTED BY CITY OF MENIFEE BUSINESS LICENSE NUMBER
�-
BUILDING PLANNING ENGINEERING FIRE
INVOICE TOTAL a� r �zz> GREEN af-' SMIP
OWNER BUILDER VERIFIED ::>YES C NO DRIVERS LICENSE# NOTARIZED LETTER YES NO
City of Menifee Building & Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-6777
oa
www.cityofinenifee.us Grry
MENIFEE
J
M,wry D. �fiohois, Chair
Ma tnear Rodriquez 1001 1 Street• P.O. Box 2815 Edmund G.Liro�rn Jr.
Secretary for Sacramento, California 95812 •UnrNv.arb.ca.gov Governor
Environmental Protection
Statewide Portable Equipment
Menifee
Registration -�uilding De
p
APR 2W
Registration No: 153097 M—�i'
Legal Owner or Operator: Duthie Electric Service Corporation,dba Duthie Power Services
Mailing Address: 2335 E. Cherry Industrial Circle
Long Beach,CA,90805
Engine Description:
CMD
Certified portable internal combustion engine,compression ignition;manufactured by Perkins,model L,
N'H70835,serial no.U193340X,raters at 98 bhp,Diesel fueled,
U.S.EPA Engine Family Name: BPKXL04.4NH1 a
Conditions: see attached
Home District: South Coast Air Quality Management District
Engine Inspection Discount: 10 or more engine discount claimed
xpiration Date:August 31,2019
f�
fi p
630 CIIPSISIMS 4ichael J.Guzzetta
Manager,Portable Equipment Registration Section
_ mforcement Division
d8131/19
The energy challenge facing California is real. Every Californian needs to take immediate action to reduce energy consumption.
For a list of simple ways you can reduce demand and cut your energy costs,see our Website:http://vnvw.arb.ca.gov.
California Environmental Protection Agency
printed on Recycled paper j
Statewide Portable Equipment.Registration
The following operating conditions apply for registration 163097
Engine Serial No.:U19334OX
General Requirements
1.-The engine shall be properly maintained and kept in good operating condition at all times.
2. The registration identification sticker shall be affixed in a visible location on the registered portable engine at all times.
The metal placard shall be securely affixed on a vertical surface of the portable engine in a location that is readily
visible from a distance.A legible Copy of the registration certificate and operating conditions shall be kept on site.with
the portable engine and shall be made accessible to the Air Resources Board or district representative upon request.
3. Engine fuel shall meet standards for California motor vehicle fuels as set forth in Chapter 5,Division 3,Title 13,of the
California Code of Regulatioris,or shall have been verified through the In-Use Strategies to Control Emissions From
Diesel Engines verification procedure per Title 13 of the California Code of Regulations commencing with section
2700.
4. This registration is not valid for operation of generators used to provide power into,the grid,except during an
emergency event or other unforeseen event that affects grid stability.
5. This registration is not valid for operation of generators used to provide primary or supplemental power to a building,
facility,stationary source,or stationary equipment except during the following scenarios:unforeseen interruptions of
power from the serving utility;maintenance and repair operations;and electrical upgrade operations that do not exceed
60 calendar days.
6. The engine and any replacement engine shall not reside at the same location for more than 12 consecutive months.
7. This registration is not valid for operation vrithin the boundaries of the California Outer Continental Shelf and State
Territorial Waters.
8. The operation of this engine shall not cause a public nuisance.
9. The portable engine shall not,be operated under both statewide registration and a district permit at any specific location.
10. The engine shall be equipped with operational and property maintained non-resettable hour time meter.
11. For each rental engine or an engine used in a third party rental transaction,the owner shall provide each person who
rents the portable engine with a copy of the registration certificate,including operating conditions,as part of the rental
agreement.
12. The operator of a portable engine or equipment unit shall obtain district authorization prior.to operation at any specific
location where the Statewide registration is not valid.
13. This registration is not valid for operation of an engine that powers an equipment unit that has been determined by the
Air Resources Board to qualify as part of a stationary source permitted by a district.
14. Except for engines owned by a rental business,the ownerloperatbr of this engine shall contact the local air district prior
to operation at an agricultural source.
15. For each rental engine or an engine used in a third party rental transaction,a written copy of the rental agreement or a
completed Form 10 must be kept onsite at all tines.
t 1tNl 'Li11 {! snd4s�
c
16. No air contaminant shall be discharged into the atmosphere for&'period or periods aggregating more than 3 minutes in
any one hour which is as dark or darker than Ringelmann 1 or equivalent to 20%opacity.
Page 1 of 4 I
The following operating conditions apply for registration 163097
Engine Serial No.:U193340X
17. For a rental engine or an engine that is part of a third party rental transaction,the rental business shall provide a written
log for recordkeeping purposes which is to be kept with the rental engine at all times.The rental business shall beep
records of the registration number of the engine;date of the start and end of the rental transaction;and written(signed)
acknowledgment by each renter of having received the registration certificate and operating conditions.The written log
shall be maintained on an annual basis and previous annual logs shall be maintained at a central location for a minimurn
of Ave years,and made accessible to the Air Resources Board or districts upon request.
18. All records shall he maintained at a central place of business for a minimum of five years,and made accessible to the
Air Resources Board or district representative upon request.
19. For non-rental engines,the operator shall record the registration number and specific location of the engine(i.e.street
address and city;or county and UTM coordinates;or other location indicator)no less than once a month.
20.. White the engine is out on rent,the rental customer shall record no l=than once a month the specific location of the
engine(i.e.street address and city;or county and UTM coordinates;or other location indicator)in the written log
provided by the owner.
Reporting&Notiticai-Mean,
21. Within 5 days of a rental transaction exceeding 9 months in duration,a rental business or the owner of a registered
engine involved in a third party rental shall submit written notification of the rental transaction to the district in which
the rental business is located.The notification shall include-the engine registration number,the rental customer
telephone number and mailing address,and estimated location of the registered engine.
22. The owner of a registered portable engine shall notify the Executive officer in writing within five days of replacing the
registered portable engine with an identical replacement.The notification shall include company name,the responsible
official,phone number,registration number,make,model,rated brake horsepower,and serial number of the identical
replacernent,description of the mechanical breakdown,and applicable fees.
' S
23. When this engine is sold,the new owner shall submit a change of ownership application within 30 days of the change in
ownership.If an application is not received within 30 days of the ownership change,the existing registration is not valid
for the new owner until the application has been filed and all applicable fees have been paid.
s -
Page 2 bf 4
;3 w
The following operating conditions apply for registration 163097
Engine Serial No.:U193340X
Fleet A�ieragp.Requiremenats
24. Except.for low-use engines and engines used exclusively in emergency applications,for engines less than 175 bhp,a
weighted fleet average PM emission factor of 0.3 gtbhp-hr shaL be met by Jnnuary 1,2013,0.I8 g/bhp-1 r shall be met
by Jana nary 1,2017,and 0.04 g/bhcrhr shall be met by Janunry 1,2020.Changes in the fleet,including engine
additions and deletions,shall not result.in noncompliance with this standard.
25. The weighted fleet average PM emission factor shall be calculated by taking the summation of the emission factor for
each engine in the fleet multiplied by the bhp rating for each engine and then dividing that summation by the
summation of the bhp ratings for all the engines in the fleet.
26. The weighted fleet average PM emission factor calculation shall use the test results from nonroad emission standard
certification,test results from a verified emission control strategy as defined in Title 13 of the California Code of
Regulations Section 93116.2,or the test results from a SCR system.All test results shall be made available to the Air
Resources Board upon request.
27. Where equipment uses grid power for more than 200 hours in lieu of operating a portable diesel engine for a given
project,the time period grid power is used may be used to reduce each affected engine's emission factor.The emission
factor for oacli affected portable engine shall be reduced proportionally by tho percentage of tine the equipment uses
grid power.
28. The weighted fleet average P14 emission factor shall include all portable engines,including those permitted or
registered with a local air district,that are owned and managed by an individual operational entity,such as a business,
business unit within a corporation,or individual city or state department under the control of Responsible Official.
Engines that are owned by different business entities that are und€:r the common control of only one Responsible
Official shall be treated as a single fleet.
29, If certified non-diesel fueled engines are part of your fleet and have been operating 100 or more hours,they may be
included toward determining compliance with the applicable fleet emission standards.A diesel PM emission rate of
zero shall be used in the fleet calculations for these engines.If the engine was added to the fleet prior to January 1,2009
,it may be counted twice in the company's fleet average determination toward compliance with the 2013 and 2017 fleet
emission standards.
30. Portable diesel-fueled engines certified to Tier 4 nonroad engine standards that are added to a fleet prior to January 1,
2015,may be counted twice in the coi:rpany's fleet average determination toward compliance with the 2013 and 2017
fleet emission standards.
Fleet R°ecordkeeping
31. Starting January 1;2012,the responsible of of a fleet shall keep records of a rts_ual.6penadng Louis for sort-diesel
fueled portable engines used as part of a coiripany's fleet average,engines affected by the use of electrification,low-use
engines,and engines used exclusively in emergency applications.
32. Altrecords pertaining to the fleet average shall be maintained at a central place of business for a minimum of five years,
and made accessible to the Air Resources Board or district representative upon request.
Fleet Reporting and Notification
33. The Responsible Official of a fleet electing to use electrification in determining the fleet average shall notify prior to the
start of the project the Executive Officer of the dates,location of the project,and make,model,serial number,district
permit or State regisimfion nurnbcr of the affected engines.In addition,the,notifiicahan shall clearly identify the
electrification acti rarity;including indicating the amount of electricity used and the tune period for the project.
34. The Responsible Official of a fleet shall submit to the Air resources Board by March 1,2013,March 1,2017,and
a March 1,2020 a signed statement of compliance that the fleet standards are being achieved.The Statement of
compliance shall include for each engine in she fleet:retake,model,serial nr'rssber,fires type,PM emission factorbhp-
hr),and district permit or State registration number.if compliance with the fleet average includes the use of
electrification,the Responsible Official shall provide documentation supporting the credit claimed for electrification.
35. As part of each statement of compliance,the Responsible Official shall,if applicable,certify that all alternative-fueled
engines included in the fleet average operated at least 100 hours during the previous 12 months prior to the fleet
emission standard becoming effective,for all engines exclusively used in emergency applications,the engines were
used only for emergency applications,for all engines using the low-use designation,the engines operated no more than
80 hours for the reporting period,and for all portable diesel-fueled engines equipped with SCR,the engine complies
with applicable district or Statewide Portable Equipment registration Program requirements.
Page 3 of 4
The following operating conditions apply-for registration 163097
Engine Serial No.:U193340X
Inspection,,Regla remencfs
36. Within 45 days after initial issuance or renewal of a registration,the owner or operator shall contact the home district to
arrange for inspection to be completed within one year of the initial registration or renewal'date.If the engine is
operating in a district other than the home district,the owner or operator may request the home district to arrange an
inspection by that other district.
37. The time for the arranged inspection shall be agreed upon in advance between the district and the company.To the
extent that an arranged inspection does not fall within the districts normal workday,the district may charge for the off-
hour time.
38. ff an arranged inspection does not occur due to unforeseen circumstances,the inspection shall be rescheduled for no
later than 90 days from the initially scheduled inspection.
39. For the purposes of scheduling inspections of multiple engines in order to qualify for an inspection fee dise6unt,the
owner or operator shall submit,within 45 days of initial rt-gistration issuance date or by January 30 of each year for
renewals,a letter of intent to the home distriet'that shall include an engine list,vith registration numbers of those to be
inspected.
40. If the engine is out of Califomia for one year or more following initial registration or renewal,the engine shall be
excused from having the arranged inspection provided that within 45 days after the date of initial registration or
renewal,the owner sends a letter to the district containing the registration number and a statement that the registered
engine or equipment unit is out of California for the one-year period.Upon the return of the engine to California,the
owner shall arrange to have the engine inspected within 30 days.
Page 4 of 4
CetlforrJs EmImnmental Pretecgon Agency EXECUTIVE ORDER U-11-022-4186
PERKINS ENGINES COMPANY LTD New Off-Road
eg Air ResO`i11P es &Wrd Compression-Ignition Engines
Pursuant to the authority vested in the Air Resources Board by Sections 43013, 43018, 43101, 43102, 43104 and
43105 of the Health and Safety Code; and
Pursuant to the authority vested in the undersigned by Sections 39515 and 39516 of the Health and Safety Code
and EXecutive Order G-02-003;
IT IS ORDERED AND RESOLVED: That the following compression-ignition engines and emission control systems
produced by the manufacturer are certified as described below for use in off-road equipment under the flexibility
program n provisions. Production engines shall be in all material respects the same as those for which certification is
granted.
MODEL YEAR FLEXIBILITY PROGRAM ENGINE FAMILY NAME(s)
APKXL06.6PJ1, BPKXL06.6PJ2, BPKXL04.4NH1, BPKXL04.4NJ1,
2013 BPKXL04.4NL1, BPKXL04.4NM1, BPKXL04.4NM2, APKXL12.5TAG,
APKXL15.2TA2,APKXL15.2TAG,APKXLIS.ITAG
BE IT FURTHER RESOLVED:That for the list-ad engine models,the manufacturer has submitted the information and
materials to demonstrate certification compliance with 13 CCR Section 2423, subpart(d).
BE IT FURTHER RESOLVED:That for the listed angine models, tie manufacturer has submifted the information and
materials to dernonstrata certification carr;piiance vi th 13 CCR Section 242-4,(in?i lion contrail labels), and 13 CCR
a
Sections 2-425 and 2426(emission control system viarranty).
Engines cerdfied under this,Ex%utive Order muse cIlnibrari to all appiicable California emission rrnulations.
Thin Ex*cutav*Or&-aF ao on-gy dn- ro'iht-h @nd aora)6ag-year lived above. Engka :; cr. {Esl
Mm.Ify thaT ar e produa--;�d 4 8)'?ony w2l;-'��v W caveved by Ws 'Executive Order.
Executed at El Monte, California on this day of December 20,12.
Annette Hebert, Chief
Mobile Source Operations Division
P4 Quiet Power Rental Series
, ��d ��25
�ener�ating 5y�sterrgs ��® Q
0P0u
Standby Rating: 83 .%VA/W kli,/ ,
-rime Rating: 75 kvA 0 60 k43i1
Q-)p n 26
ltae dby Rating: 125 WA 1 1 00tftA9
Prime'Rating: 1'13 WA
GENERATOR FEATURES Perkins Diesel Ene&es
• Perkins Tier 3/Flex engine • Heavy Duty, 4-cycle, direct Injection,turbocharged
Brushless Alternator with PMG motor starting diesel engine for maximum reliability
performance m EPA FLEX Products (TIER 3 Technology) JP-8
Digital engine generator controller w/redundant Compatible
analog gauges-meters for ease of use ® Fuel efficient
iVlgulti voltage stivitch e,uith utility power in both Q Robust construction
1201240 and 120/203 modes � Electronic fuel system and governor control
Buss bar, Gad—Lo., and utility nutlets llor cus maintains frequency from no load to gull load
t o riser conne;tioins
,; €g gauge, pov der coated, lockable, :soundi iSc rJ� +
alramuated enclosure 0 Oversizad PMOG ai't rrrin'ors'lor batter
Large capacity dual containment fuel cell motor starting
with environmental containment basin
Single point lift L G; i el ror carrn'(?Oiz
Available with or without trailer
Custom branding options available Hanco GSC400 Plus Digital Genset controller for
precise voltage and frequency regulation, and en-
J,gs acy r am��ga,rims and alternator protection
'
Pulode1 VoRages Standby Prime Engine mooW Alternator
kVA/K'b"1d WA/KbIV Brand
Hanco
Meccalte
Qp®® 120/208 240/480 83 WA/66 KW 75 WA/60 KW 1104D-E44TG1 Newage
Marathon
Hanco
QP125 120/208 240/480 125 WA/100 KW 113 WA/90 KW 1104D-E44TAG2 Meccalte
Newage
Marathon
QP80 and QP125
Engine Data QP-00 QP-125
Engine Mfg PERKINS PERKINS
Model Number 1104D-E44TG1 1104D-E44TAG2
Spec## NH70835 NJ70787
Prime output HP 87 134
Standby Output HP 97 149
Emissions certification Tier 3/Flex Tier 3/Flex
Fuel tank capacity-Gallons 1.50 150
Fuel consumption at prime rating 4.9 gal 7.3 gal
25% load 1.6 2.1
50% load 3.2 4.25
75% load 4.4 5.8
100% load 5.3 7.9
Available voltages 120/208 240/480 120/208 240/480
277/480 volt prime amps 90 136
277/480 volt standby amps 100 151
120/208 v prime amps 208 314
120/208 volt standby amps 231 347
120/240 volt prime amps 181 272
120/240 volts standby amps 200 301
Enclosure data
Length -Enclosure only 120" 120"
Width 44.5" 44.5"
Height 72" 72"
Weight-dry 4850 Ibs 4950 Ibs
Length with trailer 192" 192"
Width with trailer 76" 76"
Height with trailer 82" 82"
Weight with trailer 6050 Ibs 6050 Ibs
Weight with trailer ready to run 7170 Ibs 7270 Ibs
Sound dBA level @ 23 ft. 67 dBA 69 dBA
Distributed By:
HANCO Generating Systems
11690 N.132nd Ave.-Surprise,AZ 85379
877-779-3581 - www.southwestProducts.com
Specifications and Descriptions are accurate as known at the time of publication but are subject to change without notice. Illustrations may include
optional equipment and accessories.