PMT18-01666 City of Menifee Permit No.: PMT18-01666
29714 HAUN RD. Type: Residential Electrical
�f-�CCELA MENIFEE, CA 9258E
MENIFEE Date Issued:
05/17/2078
PERMIT
Site Address: 30384 VILLAGE KNOLL DR, MENIFEE, Parcel Number:
CA 92584 Construction Cost: $5,931.52
Existing Use: Proposed Use:
Description of SOLAR TR 37179 THE VILLAGE MASTER PC PMT17-04339
Work: 7 MODULES,7 INVERTERS,2.24 kW
LOT 115
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
SAMANTHA MAZELLA License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description Qtv Amount 1E1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
Y,♦;S`
...Menifee
DATE:4/10/2018 PERMIT/PLAN CHECK NUMBER ' OI
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-2.24 kW, 7 pcs, Master Solar Permit No: PMT 17-04339
Plan No: 1705
PROJECTADDRESS 30384 Village Knoll Dr ZIP 92584
ASSESSOR'S PARCEL NUMBER LOT 115 TRACT37179
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
APPLICANTNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO
BUSINESS NAME Lennar Homes of California
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATEELIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ g7�1. 60- ,ySoF�T � LSQFT
APPLICANT'S SIGNATURE U/ / �'//"�`� DATE 4/10/2018
Alig,STAFF USE ONLY _
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY:
PERMIT FEE yj?. SMIP GREEN
PLAN CHECK FEE INVOICE TOTAL
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 9258 O e
www.cityefirrienifee.us
APR 1 12018
Received
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 12.240KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 7 PCS.1 LG I LG320EIK-A5(320W) BUYER:
INVERTER 1 7 PCS.1 ENPHASE I I126PLUS-72-AGM-US ����OF
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 BUILDING
MOD CITY 7 NA NA NA BUYER:
TILT IB' NA. NA' NA' PLANAPF
AZIMUTH 270° NA' NA- NA' DATE:
City of Menitee REVI
Building Dept. �JE
APR 12 'L t
[APPrava!o these,
aPPrOval Of my viol
Received regulaiionsa dOr&
jObsite until Ompk
3'-0' 5'-6'
F_— ——————
I I
I
I
SOLADECK WIRE
TRANSITION BOX L
(UNDER ARRAY)
PV AC DISCONNECT I
EXTERIOR-GARAGE
UTILITY METER B
MAIN SERVICE PANEL I
(VERIFIED BY BUILDER) I ��
AC COMBINER BOX L------ ► J
bA
to
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 1705 ELEVATION C LEFT ENH OPT
ORIENTATION 3 LOT#115
LENNAR: ORIGINAL BY:JIM PARKS DATE:1&.02.07
MENIFEE TOWN CENTER 980 MONTECITO DRIVE.#302 REVIEWED BY:T.HAMMERBACHER DATE:18.02.08
DA4 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
�Rmamasri§
30LA[
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circle
INDIVIDUAL 30384 VILLAGE KNOLL DRIVE Suite 700
PLOT PLAN 1/16'=1'-0' MENIFEE,CA BWIEer.CO 80301
SYSTEM LAYOUT 303.007.0300
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY I MANUFACTURER MODEL NOTES TRADE
1 7 1 LG L6320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE IQ6PLUS-72-ACM-US MICROINVERTER SOLAR
2 1 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 311 SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V,30A SOLAR Avircc
4 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR.240V SOLAR
5 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR CTN
b I ENPHASE TBD PV BREAKER,I X 20A-2P.I X 5A-ZP SOLAR F
7 I CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR ,
B I TBD TBD SERVICE PANEL.200A BUS BLDR. ELET
9 I TBD TBD UTILITY METER.IPH,120/240V.200A BLDR. E
10 1 TBD TBD GROUNDING ELECTRODE.UFER BLDR, EILGRRJ
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCUL
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 BUS RATING AMPS 200
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40
TEMP.DELTA LOW(T08tra) 7nW-7rEsr °C -27 PV OCPD DEVICE USED AMPS 20 f C011al
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: crany ( V751o08
MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) MIA X 701ODSI. 8.19A OF CURRENT
MOD. POWER STC(P) AC MODULE SPEC WATTS 00 320 B.19A X 1.25' 10.24A 5. This of app
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 nE-iry wOn A 2DA12P 2 SPACE PV BACKFEED IREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT OAC) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60 159.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741/IEEEI547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC STY 7
BRANCH CIRCUIT OUTPUT,IMAXBC (IAC•MOD.QTY SO AMPS(AC) 8.19
AC MODULE QUANTITY,TOTAL MOD. OTY T OTY 7
TOTAL SYSTEM OUTPUT IMAXTS OAC`MOD. OTY T) AMPS(AC) 1 8.19
CONDUCTOR SIZING CALCULATIONS
D CONDITION OF USE(CCU): (AMPACITY-TEMP.DERATE `FILL DERATE)VS. REO'D(IMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS. P P.REQ'D,(IMAX• 1.25)
KEY SIZE CU/AL INSULATION CALL' AMPACITY W/O TEMP. FILL RESULT REO'D OCD
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A =12CUTHWN-2 COU 30 =761,122.80 8.19
TERM 2525 10.24 20
B NM-B COU 40 36.40 8.19
TERM 3535 10.24 20
C NM-B COU 40 36.40 8.19
TERM 3535 10.24 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
p 1-#12 ENPHASE G CABLE.1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR
B 1 3-910•, I-7t10 EGC I CU NM-B(ROMEX) I INTERIOR I SOLAR
C 13410.I-#10 EGG I CU NM-B(ROMEX7 I INTERIOR ISOLAR
'NEUTRAL CAPPED AND NOT USED _
O
O
4 !1FT
2DA/2P
_�N
G G — _ G
A a L 6 -le
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.240KW
LOT#115
ORIGINAL BY:JIM PARKS I DATE:
LENNAR: 18.02.07
MENIFEE TOWN CENTER REVIEWED BY:T.HAMMERBACHER I DATE: 10.02.O8
980 MON7ECIT0 DRIVE.#302
DA4 CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namasb�
vouv
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707Wncheder Circle
INDIVIDUAL 30384 VILLAGE KNOLL DRIVE Su4e 700
PLOT PLAN 2 NTS MENIFEE,CA Boulder,CO 80301
ELECTRICAL 303447.0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMO LINT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH({')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND 1'E ARTII
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)AN ANIMAL GUARD SHALL BE INSTALLED ARGUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
11)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(10 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED.TO BE INSTALLED OVER TILE.
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ti be a per
federal,a
zd lansm(p
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POIM OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT k.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:JIM PARKS DATE:18.02.07
MENIFEE TOWN CENTER q80 MO TECITO DRIVE,#302 REVIEWED BY:T-HAMMERBACHER DATE:18.02.08
DA4 CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namast€
— ti $ou•
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 W rIchesler Circle
INDIVIDUAL 30384 VILLAGE KNOLL DRIVE Suite 700
PLOT PLAN 3 NITS MENIFEE,CA Boulder,CO 80301
NOTES 303.447.03D0
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE 1NT
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
143
Aforloran
or city
kept on the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BO%
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 8. 19A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY:JIM PARKS DATE:16.02.07
MENIFEE TOWN CENTER 980 MONTECITO DRIVE.#302 REVIEWED BY:T.HAMMERBACHER I DATE:18.02.08
DA4 CORONA,CA 92879 REV.# BV DATE I DESCRIPTION •'
namashidi
I SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Wn&oster Circle
INDIVIDUAL 30384 VILLAGE KNOLL DRIVE Suite 700
PLOT PLAN 4 NTS MENIFEE,CA Boulder,CO 8=1
PLACARDS 303,"T.0300