PMT18-01665 City of Menifee Permit No.: PMT18-01666
29714 HAUN RD. Type: Residential Electrical
4'7A-CCIELA- MENIFEE,CA92586
MENIFEE Date Issued: 05/17/2018
PERMIT
Site Address: 30382 VILLAGE KNOLL DR, MENIFEE, Parcel Number:
CA 92584 Construction Cost: $5,931.52
Existing Use: Proposed Use:
Description of SOLAR TR 37179 THE VILLAGE MASTER PC PMT17-04339
Work: 7 MODULES,7 INVERTERS,2.24 kW
LOT 114
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
SAMANTHA MAZELLA License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description Amount($
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pemrit_Template.rpt Page 1 of 1
SAFETYBUILDING & • APPLICATION
Men ifee
DATE:4/10/2018 PERMIT/PLAN CHECK NUMBER
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit- 2.24 kW, 7 pcs, Master Solar Permit No: PMT 17-04339
Plan No: 1577
PROJECTADDRESS 30382 Village Knoll Dr ZIP 92584
ASSESSOR'S PARCEL NUMBER LOT 114 TRACT37179
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO
BUSINESS NAME Lennar Homes of California
ADDRESS 980 Montecito Dr„ Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 5�.31' V a SO FT L SQ FT
APPLICANT'S SIGNATURE DATE 4/10/2018
CITY STAFF USE ONLY _DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIFE ACCEPTED BY:
PERMIT FEE o2��l�,�v SMIP GREEN f —
PLAN CHECK FEE INVOICE TOTAL
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
R ern ee
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-61Yihft Dept.
www.cityqfi,T;enifee.us
APR 1 3 2018
e elve
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.24OKW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 7 PCS.1 LG I LG320EIK-AS(320W) BUYER:
INVERTER 1 7 PCS,I ENPHASE I 106PLUS-72-AGM-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE-
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 7 NA NA NA BUYER: .yf
TILT 23' NA• NA° NA* alp Uv
�1
AZIMUTH I 90° I NA' I NA' NA' DATE: lieap
City
of Nienitee us Jo'm 8 e
Building E)ePt-
APR 1 GJi3
Received
1N Wl�
I
I a I
I f I
I I
I I
I py
SOLADECK WIRE
TRANSITION BOX I I
(UNDER ARRAY)
PV AC DISCONNECT _J
EXTERIOR-GARAGE
UTILITY METER 8 °`�°
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOX—,-A
OX _J
III Q
uio
�-
NOTE:.DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 1577 ELEVATION A LEFT ENH OPT
ORIENTATION 3 LOT#114
LENNAR: ORIGINAL BY:J1M PARKS DATE: 18.02.07
MENIFEE TOWN CENTER REVIEWED BY:T.HAMMERBACHER DATE: 18.02.08
9OR NA,C 92 DRIVE.#302
DA4 CORONA,CA 92079 REV.# BY I DATE I DESCRIPTION
- I V namasCB
fOIA!
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circle
INDIVIDUAL 30382 VILLAGE KNOLL DRIVE Suite 700
PLOT PLAN 1 1/16'=1'-0' MENIFEE.CA Boulder,DO 80301
SYSTEM LAYOUT 303.447.0300
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY I MANUFACTURER MODEL NOTES TRADE
1 7 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR
2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221LIRB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR
5 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR
6 1 ENPHASE TBD PV BREAKER,1 X 2OA-2P.I X 5A-2P SOLAR
7 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR de jo Y
8 1 TBD TBD SERVICE PANEL.200A BUS BLDR.ELEC.
9 1 TBD TBD UTILITY METER, IPH, 120/240V,200A BLDR.ELEC. UDISIAC
10 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR.ELEC.
sUO3 al
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMME
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 200
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40
TEMP.DELTA LOW(TOELTA) THIN-TTEST 'C -27 PV OCPD DEVICE USED AMPS 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS:
MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) I.17A x 701ODS)= 8.I9A OF CURRENT .04
MOD.POWER STC(P) AC MODULE SPEC WATTS(B0) 320 6.19A x L25= 10.x4A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20AI2P 2 SPACE PV BACKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 d3 3 Al
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741 I IEEEI547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC GTY 7
BRANCH CIRCUIT OUTPUT,IMAXBC (IAC-MOD.QTY B0 AMPS(AC) 8.19
AC MODULE QUANTITY.TOTAL MOD. OTY T GTY 7
TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD. OTY T) AMPS(AC) 1 8.19
CONDUCTOR SIZING CALCULATIONS
1)CONDITION OF USE(COU): (AMPACITY•TEMP. DERATE` FILL DEBATE)3 REO'D OMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS. Vs.REO'D,(INAX = 1.25)
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCO
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A *12 CU THWN-2 COU 30 .76 1.0 22.80 8.19
TERM 25 25 10.24 20
B #10 CU NM-B COU 40 .91 1.0 36.40 8.19
TERM 35 35 10.24 20
C #10 Cu NM-B COU 40 .91 1.0 36.40 B.19
TERM 35 35 10.24 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENPHASE 0 CABLE,I-#6G.FREE AIR CU I UL3003.DG CABLE I ARRAY SOLAR
8 1 3-A10 I-#10 EGC Cu I NM-B(ROMEX) I INTERIOR I SOLAR O
C 13410.1410 EGC I Cu I NM-B(ROMEX) I INTERIOR I SOLAR
'NEUTRAL CAPPED AND NOT USED
M —
O
4 Q
O 5`12v
--IN
N
G G G
A B C C = 10
ROOF t EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.24OKW
LOT#114
ORIGINAL BY:JIM PARKS DATE:
LENNAR: 18.02.07
MENIFEE TOWN CENTER REVIEWED BY:T. HAMMERBACHER I DATE: 18.02.08
980 MONTECITO DRIVE,#302
DA4 CORONA,CA 92879 REV.# BY DATE DESCRIPTION If
namasGe
sous
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Wwhester Circle
INDIVIDUAL 30382 VILLAGE KNOLL DRIVE Suite 700
PLOT PLAN 2 NTS MENIFEE,CA Bouker,CO 60301
ELECTRICAL 303.417.03DO
INSTALLATION NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION. uoligi
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(19 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. -141SB9UeW I
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ue 0 U011eI0
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 11E 49 sueid
IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 8
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.•
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. A V
AM
,VS GNd
3 HIN2
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)EMPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMANLIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:JIM PARKS I DATE:18.02.07
MENIFEE TOWN CENTER g80 MONTECITO DRIVE.#302 REVIEWED BY:T. HAMMERBACHER DATE:18.02.08
DA4 CORONA,CA 92879 REV.# 8Y DATE I DESCRIPTION
namast6
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707VAoclester Circle
INDIVIDUAL 30382 VILLAGE KNOLL DRIVE Suite 700
PLOT PLAN 3 NTS MENIFEE.CA Bouldw,,CO 80301
NOTES 303.467.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE ellsgo(
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS a suolleldej
ARE LOCATED AS SHOWN. ':a leAoidde
lenaddV,
^AMAM
7 NV Id
aims
t� Ailo
SOLADECK WIRE
TRANSITION BO%
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER&
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOX
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 8. 19A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY:JIM PARKS DATE:18.02.07
MENIFEE TOWN CENTER 980 MONTECITO DRIVE.#302 REVIEWED BY:T.HAMMERBACHER DATE:18.02.08
DA4 CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Vncimast;6
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Vdnrh .r Circe
INDIVIDUAL 30382 VILLAGE KNOLL DRIVE Sufie 70D
PLOT PLAN 4 NTS MENIFEE,CA Boulder,CO 80301
PLACARDS 303.447.0300