PMT18-01638 City of Menifee Permit No.: PMT18-01638
` _CCEII-i MENIFEE,CA 92586 29714 HAUN RD.
A Type: Residential Electrical
MENIFEE Date Issued:
0 511 612 01 8
PERMIT
Site Address: 26135 ST MARY ST, MENIFEE, CA 92586 Parcel Number: 337-021-041
Construction Cost: $19,000.00
Existing Use: Proposed Use:
Description of INSTALL 19 ROOF MOUNTED SOLAR MODULES, 1 WALL MOUNTED STRING INVERTER,5.7 KW
Work:
Owner Contractor
DEBBIE YOUNG PEAK POWER SOLUTIONS INC
26135 ST MARY ST 151 KALMUS DR STE L2
MENIFEE,CA 92586 COSTA MESA,CA 92626
Applicant Phone:7142583900
151 KALMUS DR STE L2 License Number:973253
COSTA MESA, CA 92626
Phone:7149076816
Fee Description ,O�t Amount($)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
Additional Plan Review Electrical 158 157.50
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 3.00
General Plan Maintenance Fee-Electrical 1 12.60
$453.10
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from Ilcensure under the Contracto(s5tate License Law for
Professions Code and my license is in full force and effect. the following reason:
License Class C- 10 License No. S By my signature below 1 acknowledge that,except for my personal residence
Expires � K—3 I—I signature .c in which I must have resided for at least one year prior to completion of
WORKER'S COMPENSATION DECLARATION improvements covered bythis permit.I cannot legallysell a structure that I
have built as an owner-builder if It has not been constructed in its entirety by
o I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which
this permit is issued, www.leginfo.m.gov/calaw.htmi
Policy# S¢ .A -- r' Date
O I have and will maintain worker's compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT
section 3700 of the Labor Code,for the performance of the work for which 0 By my signature below 1 certify to each of the following:I am the property
this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this
numberare: application and the information I have provided is correct.I agree to comply
Carrier S 4-.-� n f-r — 44.4 with all applicable city and county ordinances and state laws relating to
building construction.I authorize representatives of this city or county to
Policy# 72 U L S 8 27 Q/ lExpires enter the above identified property for inspection purposes.
(This section need not to he completed is the per it a for one-hundred Date
dgnars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT
. 1 certify in the performance of the work for which this permit is issued,
I ® p•���
shall not emolov any personsin any manner so as to become subject to the CITY BUSINESS LICENSE#
worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the worker's compensation provisions of Section 3700 of the Labor
Code,I shall forthwith comppllyy with those provisions. Will the applicant or future building occupant handle hazardous material or a
Applicant ��,_„ic_((`cU�2. Date 2 - r mixture containing a hazardous material equal to or greater that the
amounts s ified an the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS 0 Yes No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,0001,IN occupant requirel�permit for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quoream Management hecoDistrict(SCtionor modification
checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES fo Coast
Air
s
CONSTRUCTION LENDING AGENCY OYes No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed/building or modified facility be within SOLID feet of the
lending agency for the performance of the work which this permit is issued outer bougnil6i Yof a school?
(Section 3097 Civil Code) 0 Yes 6No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm under penalty of perjury that I am exempt from the
permitting checklist.I understand my requirements under the State of
i
Contractor's License Law for the reason(s)indicated below by the Califo nea Health&Safety Code,Section 25505 and 25534 concerning
checkmark(s)I have placed next to the applicable items)(Section 7031.5 ha rdous material reporting.
Business and Professions Code).Any city or county that requires a permit to es 0No
construct,alter,improve,demolish or repair any structure,prior to its
issuance,also requires the applicant for the permit to file a signed statement PROP TY OWNIER OR AUTHORIZED AGENT
that he or she is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING(RAPI
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in apre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by receiving or compensation
facilitytobeork that disturbs
ified firmsandn a pre,ply wRh
than
Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property ownersand property
than($500). managers who do the paint-disturbing work themselves or through their
❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,well do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractor's State License Law does not apply to an owner of a 0 An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that It was
not built or improved for the purpose of sale. 0 No EPA Lead-Safe Certified Firm is required for this pmject because:
o 1,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractor's State License Law,does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
_ Acknowledgement.
EsG
A SAFEbuilt Company
DATE: 05/09/2018 ❑ APPLICANT
❑ JURIS.
JURISDICTION: City of Menifee
PLAN CHECK #.: PMT18-01638 SET: II
PROJECT ADDRESS: 26135 Marys St.
PROJECT NAME: Young 5kW PV System
® The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil staff did not advise the applicant that the plan check has been completed.
❑ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
❑ REMARKS:
By: Ryan Murphy Enclosures:
EsGil
05/04/2018
9320 Chesapeake Drive, Suite 208 ♦ San Diego,California 92123 ♦ (858)560-1468 ♦ Fax(858)560-1576
City of Menifee PMT18-01638 vnfS f,+--c
04/19/2018
[DO NOT PAY— THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Menifee PLAN CHECK#.: PMT18-01638
PREPARED BY: Ryan Murphy DATE: 04/19/2018
BUILDING ADDRESS: 26135 Marys St.
BUILDING OCCUPANCY: R-3
BUILDING AREA Valuation Reg. VALUE ($)
PORTION I ( Sq. Ft.) Multiplier Mod.
PV S stem
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code mnf Manual Input
1997 UBC Building Permit Fee W
trorr you cnecf e¢ c;np 7vwcw and Hourly at the same time
1997 UBC Plan Check Fee
Type of Review: Complete Review Structural Only
Repetitive Fee Other
Repeats Hourly 1.5 Hrs. @
EsGil Fee $105.00 $157.50
Based on hourly rate
Comments:
Sheet 1 of 1
Residential Standard Calculation 92611997 YOUNG Residence
Version 2011 L
STEP 1 Article 220.42&220.52 Peak Power Solutions,Inc.
2500 General Lighting load 7,600 VA 151 Kalmus Drive,Suite L2
2 Small Appliance 3,000 VA Costa Mesa,CA 92626
1 Laundry circuit 1,500 VA 0.714-258-3900 F.714-258-3920
Gen.Lgt,Sm App.&Laun.Load 12,000 VA 4111QO188:29
3,000 VA @ 100%= 3.000 VA
9,000 VA @ 35%= 3,150 VA
VA @ 25%= VA
STEP 2 Article 220.50&220.51 i] General Lighting Demand Load 6,150 VA
AIC Condenser&Fixed Electric Space Heating CITY Total 1
s ron . 7.130 VA AHU 1 select . VA >. Heating Load VA
VA AHU 2 select . VA Qb CU Load 7,130 VA
A/c7i3 . VA AHU 3 VA QN
VA AHU 4 select . VA 12N Greater of Heat @ 100%vsJVC @ 100% 7,130 VA
VA AHU 5 select . VA qN
STEP 3 Article 220.53 Appliance Demand Load 3,818 VA
GAS . Water Heater VA
1,600 VA . 1 Refrigerator 1,600 VA Dryer Demand Load 5,000 VA
600 VA . Freezer VA
1,300 VA . 1 Dishwasher 1,300 VA Range Demand Load VA
690 VA . 1 Disposal 690 VA
400 VA . R/Hood VA Service Demand 22,098 VA
1,5DO VA . 1 Micravave 1,500 VA
❑ 4,000 VA . Micravave VA Demand Load 92 A
17o vA . Mini Refrig VA
❑ 4D0 VA . Wine CIr VA Neutral Demand 56 A
❑ 5,000 VA . Insta Hot VA
1,500 VA . Ironing Center VA Min.Service Req. 100 A
select . Jacuzzi Tub VA
❑ select . Sprinkler Pump VA Min.Feeder size 4
❑ select . Well Pump VA Min.Neutral size 6
select . Fountain Pump VA Eq.Grding Cond. 8
salsa _ . Elevator VA ❑ Copper
Pool Equip.Panel VA 100%Demand
❑ GATES VA No Demand
❑ EVSE Charger VA No Demand Total Appliance Load 5,090 VA
4 or more demand @ 75%plus 100%demand loads 3,818 VA
STEP 4 Article 220.54
Electric Clothes Dryers 5,000 VA
STEP 5 Article 220.55
Electric Ranges Col C demand 0
or Number of appliances
Cooktop W Col B demand
2 Check Box for Gas Range Cooklop W Col B demand
Oven(s) Col B demand
Oven(s) Col B demand
Number of appliances 2Dem.Factor 65%
Cooktop&Oven Demand Load W
Im011ds0comkast.net
Pod Panel Feeder Calculation (see Note) A B N Continuous Non-continuous
Continuous Motors 0 ...... 0 0 0 Motors Motors
Non-continuous 0 ...... 0 0 0 select ❑ 24N select . ❑taw
Spa heater 1ekVA _,,.. 0 0 idea . ❑ 24w select . ❑24w
Pod heater 0 0 select . ❑ 24w select . ❑24wPod heater ..... 0 0 selec . ❑ 24w select . ❑240vPool Light .. 0 0 0 select � ❑ 240v select � ❑24wBlower ❑ 240v 0 0 0
other loatl ❑ 24w 0 0 0 0.0 Motor Neutral Load
Dinar loetl ❑ zaw 0 0 0
❑Min.0 er Pool Feeder AWG AlAlA Max.Unbelanced Neutral Load
Minimum Panel Ratin A Phase Amperes Neut.load