PMT18-01566 City of Menifee Permit No.: PMT18-01566 29714 HAUN RD. Type: Residential Mechanical 'ACCELA> MENIFEE, CA 92586 r.,..,..-.ASA.r MENIFEE Date Issued: 04/03/2018 PERMIT Site Address: 26225 LANCASTER DR, MENIFEE, CA Parcel Number: 335-132-018 92586 Construction Cost: $5,500.00 Existing Use: Proposed Use: Description of HVAC SYSTEM REPLACEMENT, ROOF MOUNTED SPLIT SYSTEM PACKAGE, 3 TONS, 16 SEER Work: Owner Contractor LAJUANA MALONE PINEDA GENERAL CONSTRUCTION INC 26225 LANCASTER DRIVE 15323 AGUILA PASS MENIFEE,CA 92586 NUEVO, CA 92567 Applicant Phone: 9513859149 ARTURO PINEDA License Number: 889740 PINEDA GENERAL CONSTRUCTION INC 15323 AGUILA PASS NUEVO, CA 92567 Fee Description G,]yt Amount($1 Forced-Air or Gravity-Type Furnace or Burner 1 149.00 Air Handling/Condensing Units SFR 1 133.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 General Plan Maintenance Fee-Mechanical 1 14.10 $324.10 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE property who builds or improves thereon,and who contracts for the projects LICENSED DECORATION with a licensed contractor(s)pursuant to the Contractors State License Law). I hereby affirm under penalty'of perjury that I am under provisions of ❑I am exempt from licensure under the Contractors State License Law for Chapter9(commencing with section 7000)of Division 3 of the Business and the following reason: Professions Code and my license is in full force and effect. '\ personal residence License Class License No• 16��u v By my signature below I acknowledge that,except for my p \`\ in which I must have resided for at least one year prior to completion of Expires 'SI ) Signature improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by rstand ❑I hereby affirm under penaltyat perjury one of the following declarations:I licensed the Business and Professions Code,is available upon request when t a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which www.Ieglnfo.ca.gcy1caI1w.htmI- this permit is issued. Date Policy# 0'3 PROPERTY OWNER OR AUTHORIZED AGENT o I have and will maintain workers compensation insurance,as required by D By my signature below I certify to each of the following:I am the property section 3700 of the Labor Code,for the performance of the work for which owner or authorized to act on the property owners behalf-I have read this this permit is issued.My workers compensation insurance carrier and policy application and the information I have provided is correct.I agree to comply number are: with all applicable city and county ordinances and state laws relating to Carrier � CGNXp �(LS �� building construction.I authorize representatives of this city or county to Paliry# n )3'a31'5 Expires 's )r� I�.tJ( � enter the above identified property for inspection purposes. Date (This section need not to be completed is the permit is for one-hundred PROPERTY OWNER OR AUTHORIZED AGENT dollars($100)or less ❑1 certify that in the performance of the work for which this permit Is issued, CITY BUSINESS LICENSE# I shall not emolov any persons in any manner so as to become subject to the HAZARDOUS MATERIAL DECLARATION workers compensation laws of California,and agree that if I should become subject to the worke compensation provisions of Section 3700 of the Labor Will the applicant or future building occupant handle hazardous material or a Code,I sh orthwit co ly with those provisions. ``OQ' — mixture containing a hazardous material equal to or greater that the Applicant Date `� amounts specified on the Hazardous Materials Information Guide? Dyes ONO WARNING:FAILUWf.Z0_S_Et&RE WORKER'S COMPENSATION COVERAGE IS Will the intended use of the building by the applicant or future building UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will th intendedquire uspermit ofhe billingr the by or or frillingom South AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN Coast Air Quality Management District(SCcton or See permitting checklist ADDITION TO THE COST OF COMPENSATION,DAMAGES ATTORNEYS FEES R IN SECTION 3706 OF THE LABOR CODE,INTEREST, for guidelines Dyes ONO CONSTRUCTION LENDING AGENCY I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the outer boundary of a school? lending agency for the performance of the work which this permit is Issued oyes ❑No (Section 3097 Civil Code) I have read the Hazardous Material Information Guide and the SCAOMD OWNER BUILDER DECLARATIONS permitting checklist.I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning Contractors License Law for the reasons)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 oyes ❑No Date Business and Professions Code).Any city county that requires a permit to PROPERTY OWNER OR AUTHORIZED AGENT construct,alter,improve,demolish or repair any structure,prior to its issuance,also requires the applicant for the permit to file a signed statement EPA RENOVATION REPAIR AND PAINTING IRRP) that he or she is licensed pursuant to the provisions of the Contractors State License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property ($500). managers who do the paint-disturbing work themselves or through their thanloyal with wages as their sole employees.For more information about EPA's Renovation Program visit: ❑ as owner of the property,or my emp f portion of the work,and the structure is www eoa eov/lead or contact the National Lead Information Center at all o or compensation,will do( ) ( )P 1-800-424-LEAD(5323). not intended or offered for sale.(Section 7044,Business an an Professions of a Code;The Contractors State License Law does not apply o An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the Certified Firm Name: property provided that the improvements are not intended or offered for sale.If,however,the building or improvement is sold within one year of Firm certification No.: completion,the Owner-Builder will have the burden of proving that it was ❑No EPA Lead-Safe Certified Firm-is required for this project because: not built or improved for the purpose of sale. o I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions If Code:The Contractors State License Law does not apply to an owner of a AYour project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION MENIFEE DATE: PERMIT/PLAN CHECK NUMBER PLANNING CASE NUMBER TYPE: O COMMERCIAL RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL MECHANICAL O NEW O PLUMBING C) RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK v \a J- A wh1E c Jt&\S bL# sn eC - 1 PROJECTADDRESS 'f,(p�L'L� "cwsa Dr. San Ui,13 � CA ZIP c-1v50010 ASSESSOR'S PARCEL NUMBER 2 IZ9-0\% LOT TRACT OWNER NAMELm�o City of AWAfte ADDRESS ,, c: A- ✓e� (, S ilding Dept. PHONE (2LS)7WIh—IS 101 EMAIL APR U3 2018 I�— APPLICANT NAME ADDRESS 2 0 050� `1'tJ'� a�i0 'L PHONE (cIcWMbs-Gi L k4 a1 EMAIL Qj!ZyjNo.,'k\, CONTRACTOR'S NAME .a,,c, -I;%C• OWNER BUILDER? O YES)�`NO BUSINESS NAME QS,t\� c% On 'j:A C,. ADDRESS U-ftAa 2 PHONE `3S I, S°O.S—q ft j O) EMAIL CONTRACTOR'S STATE LIC NUMBER (6e0-A-+ 1 C) LICENSE CLASSIFICATION VALUATION$ 5 1 S[5Q.� SQ FT i , l"01 L SQ FT ,3 APPLICANT'S SIGNATURE DATE HI'SI JY, CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIREVjP INVOICETOTAL , 'O GREEN 1 SMIP X OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER C YES O NO City of Menifee Building & Safety Department 129714 Haun Rd., Menifee, CA 92586 (951)672-677 www.cityofinenifee.us t Y.' ENIFE STATE OF CALIFORNIA ALTERATIONS - HVAC CEC-CFI R-ALT-04-E Revised 01116Itz ORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-04-E Alterations-HVAC CZ 2,and 8-15 (Page 1 of 1) Site Address: Enforcement Agency: Date Prepared: Permittt: 1. cor 9'456b Equipment Type Equipment Efficiency New Ducting or Lineset: Conditioned 2 Thermostat Required R-value Floor Area(k) Packaged 11 Evaporator Coil -18&AFUE LJ_Q COP R-6 (CZ 1-10,12&13)Ducts. Served by system kSetback System Condensing Unit 0R-81 (CZ 11,14-16)Ducts ).)U?I ftZ (ffnotafready ❑Split System 11 compressor i(O SEER 3S,9111 HSPF present must ❑t R-2.8 Lineset` ❑Mini Split ❑Lineset t�^- EER - be installed) ❑Furnace ❑TXV ��"OS `�" A� s+a city f Menifee HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At peri IAJd)Iggi4a*, form is allowed to be filled out by hand. For final inspection all forms are to be registered(no hand filled forms allowed)and a copy left on site. .HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: All Equipment, CF1R-ALT-02-E Condenser Unit,Evaporator Coil, CF2R-MCH-03-E,MCH-20-H,MCH-(23 or 24)'-H,MCH-25-1-12 Compressor,TXV,Lineset, CF3R-MCH-20-H,MCH-(23 or 24)-H2,MCH-25-H2 ° Air Handler/Furnace'(Can include new ducting) ce i Y ei ci Installer Requirement:Duct leakage(515%,or 510%to outside,or seal all accessible leaks),Air Flow>_300 CFM/ton,Refrigerant Charge. Exempted from duct leakage testing if: ❑1.Duct system registered with HERS provider as previously sealed,or 0 2.There is less than 40 linear feet of duct In unconditioned space,or ❑3.Existing duct systems are constructed,insulated or sealed with asbestos(list manufacture date of building I ❑2.New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts' CF1R-ALT-02-E including Mini Split CF2R-MCH-01-E,MCH-20-H,MCH-22-H,MCH-(23 or 24)-H2,MCH-25-H2 CF3R-MCH-20-H,MCH-22-H,MCH-(23 or 24)-H2,MCH-25-1-12 Mini Splits require CF1R-ALT-02-E,CF2R-MCH-01-E,and(CF2R-CF3R)MCH-25-H Installer Requirement:Duct leakage<5%,Fan Efficacy(0.58W/CFM),Air Flow z 350 CFM/ton(or alternative),Refrigerant Charge ❑3.All New Ducts with Replacement I Required Compliance Documents to be left on site for Final: All New Ducts'and one or more of the following CF1R-ALT-02-E replaced:Condenser Unit,Evaporator Coil, CF2R-MCH-01-E,MCH-20-H,MCH-(23 or 24)-H,MCH-25-H Compressor,TXV,Lineset,Furnace CF3R-MCH-20-H,MCH-(23 or 24)-H,MCH-25-H Installer Requirement:Duct leakage 55%,Air Flow_350 CFM/ton(or alternative),Refrigerant Charge Exempted from duct leakage testing if:0 1. Existing duct systems are constructed,insulated or sealed with asbestos ❑4.New Ducting over 40 feet Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts' CFiVALT-02-E,CF2R-MCH-20-H,CF3R-MCH-20-H Installer Required to:Duct leakage(515%or,510%to outside or,or seal all accessible leaks) ❑ EXCEPTION:Existing duct systems constructed,insulated or sealed with asbestos. t All new ducting requires R-8 insulation when more than 40 ft installed in CZs 11&14-16 and R-6 in CZs 1-10,12&13,and R-6 insulation when less than 40 it Installed.This includes in walls,between floors etc. 2 Heating only systems and Air Handler/Furnace changes do not require Air Flow MCH-(23 or 24),or Refrigerant Charge verification MCH-25 'All New Ducts is when at least 75%of the duct system is new duct material,and up to 25%may consist of reused parts from the dwelling unit's existing duct system(e.g.,registers,grilles,boots,air handler,coil,plenums,duct material) 4 R-2.8(1"thick insulation)for linesets 1"and less. Contractor(Documentation Author's/Responsible Designer's Declaration Statement) I certifythe following under penalty of perjury,under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and performance specifications for the design Identified on this Certificate of Compliance conform to the requirements of Title 24,Parts 1 and 6 of the California Code of Regulations(CCR). 4. That the energy features and performance specifications,materials,components,and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24,Part 1 and Part 6 of the CCR. S. The building design features or system design features Identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,worksheets,calculations,plans and specifications submitted to the enforcement agency for approval with this building permit application. sponsihle !Ter Name: Res n oe rSlgnature: Date t; :l en�s� 0 Company: Address: IC�ev/State/Zip: Phone: Aa eA X,r Cc,44v 1"0N� 1'60109 t�l e A CA CW -4- `l Z, -mi l For assistance or questions regarding the Energy Standards,contact the Energy Hotline at:1-800-772-3300 T"M - 6"yo TECHNICAL DATA SHEET STOCK NO. 4225XXX June, 2016 CAMBRIDGE COOL COLORS This heavyweight, laminated shingle is composed of a dimensionally stable non-woven glass fiber mat, which is thoroughly impregnated with stabilized waterproofing bitumen. Cambridge Cool Color is distinguished by its random shake-look design, uniform or dual band shadow coloration, and superior thermally activated shingle sealant. Colored, reflective ceramic granules surface the top of both layers of this shingle to protect the asphalt from ultraviolet radiation and reduce the amount of heat conducted to the building below. Each shingle has release tape and mineral powder applied to the underside,thus preventing any sticking in the bundle. Suitable for application on roof slopes greater than 4:12. Underlayment is strongly recommended for slopes below 6:12. They may also be applied on low slope roofs(2:12 to 4:12)providing the deck is covered with two plies of felt or one ply of any IKO Ice & Water Protector. This shingle conforms to requirements of CSA A123.5, ASTM D3018, ASTM E108 Class A, ASTM D3462, ASTM D3161 Class F, ASTM D7158 Class H and is California Title 24 compliant. IKO's asphalt shingles are produced and designed with consideration for environmental responsibility and sustainability, incorporating quality recycled components whenever possible, manufactured in facilities that comply with the most stringent government environmental regulations, and can therefore be a part of any "green" construction project. CtZ(2C =0 : t21u-I- OGo� C NOMINAL TEST STANDARD CHARACTERISTIC UNITS VALUE METHOD LIMITS QUANTITY PER PALLET: 56 - N/A PALLET SIZE: cm (in) 101 x 135 - (40 x 53) LENGTH: mm (in) 1038 (40 7/8) - ±6(± 1/4) WIDTH: mm (in) 349 (13 3/4) - ±3 (± 1/8) HEADLAP: mm (in) 50 (2) - MIN: 50 (2) BUNDLE QUANTITY: 20 - - COVERAGE PER BUNDLE: ftZ(m) 33.3 (3.1) - EXPOSURE: mm (in) 149 (5 7/8) - TEAR STRENGTH: g PASS ASTM D1922 MIN: 1700 HEAT RESISTANCE: - PASS 90°C (192°F) STABILIZED BITUMEN WEIGHT: g/m2 (lbs/100 ftZ) PASS ASTM D228 MIN: 2000 (41) GRANULE RETENTION: % PASS ASTM D4977 MIN: 86 FIRE RATING: CLASS A ASTM E108 MIN: CLASS A 'Sample shows no sliding or dripping of the bitumen coating when suspended vertically in an oven at 90°C(192'F)for 2 hours. See also Material Information Sheet— MIS# 1713 The information on this Technical Data sheet is based upon data considered to be true and accurate,based on laboratory tests and production measurements,and is offered solely for the user's consideration,investigation and verification.Nothing contained herein is representative of a warranty or guarantee for which the manufacturer can be held legally responsible. The manufacturer does not assume any responsibility for any misrepresentation or assumptions the reader may formulate.